INSTRUCTIONS TO THE HOMEOWNER

WARNING

FIRE OR EXPLOSION HAZARD

CAN CAUSE PROPERTY DAMAGE, SEVERE IN-

JURY, OR DEATH

Follow these warnings and lighting instructions

exactly.

1. Before  lighting,  smell  all  around  the  appli-

ance  area  for  gas.  If  appliance  uses  LP

(bottled)  gas,  also  be  sure  to  smell  next  to

floor  because  LP  gas  is  heavier  than  air.  If

you smell gas, immediately shut off the man-

ual valve in the gas piping to the appliance.

ON LP SYSTEMS, AT THE TANK. Do not try to

light  any  appliances  in  the  house.  Do  not

touch  electrical  switches  or  use  the  phone.

LEAVE THE BUILDING and call your gas sup-

plier  from  a  neighbor’s  house.  If  your  gas

supplier cannot be reached, call the fire de-

partment.

2. Do  not  force  the  gas  control  knob  on  the

appliance. Use only your hand to push down

or turn the gas control knob. Never use any

tools. If the gas control knob will not operate

by hand, the control should be replaced by a

qualified  service  technician.  Force  or  at-

tempted repair may result in fire or explosion.

3. The  control  must  be  replaced  if  it  has  been

flooded with water.

4. The control is a SAFETY DEVICE. It must be

replaced in case of any physical damage, tam-

pering,  bent  terminals,  missing  or  broken

parts, stripped threads, or evidence of expo-

sure to heat.

IMPORTANT

Follow  the  appliance  manufacturer’s  instructions.

The  information  below  will  assist  in  typical  control

applications,  but  the  specific  controls  may  require

special manufacturer instructions.

Lighting the Pilot Burner

STOP: Read the warning above.

This appliance has a pilot burner which must be lit by

hand. If the pilot flame has gone out, follow these instruc-

tions exactly.

1. Set the thermostat to lowest setting.

2. Turn off all electric power to the appliance.

SERVICE

CAUTION

Never  apply  a  jumper  across  (or  short)  valve  coil

terminals. This may burn out thermostat heat antici-

pator.

IMPORTANT

Allow  30  seconds  after  shutdown  before  reener-

gizing step-opening model to ensure lightoff at step

pressure.

IF PILOT WILL NOT LIGHT

1. Make sure the main gas supply valve is open and the

pilot gas supply line is purged of air.

2. Attempt  to  light  pilot  following  procedure  in  “Light

Pilot”, page 4.

3. Then if:

a. Pilot  gas  adjustment  screw  is  closed,  readjust

pilot flame. Refer to page 4.

b. Compression fitting has a gas leak, replace old

compression    fitting  or  tighten  new  one.    Refer  to

page 3.

c. Pilot burner tubing or orifice is clogged, replace

combination gas control. Refer to page 1.

IF PILOT GOES OUT WHEN GAS CONTROL KNOB IS

RELEASED

1. Make sure the gas control knob is held in at least one

minute to allow the generator time to heat.

2. Check pilot flame adjustment, refer to page 4.

3. Check  the  wiring  between  the  generator  and  the

valve operator in the gas control.

4. Make sure jumper between valve operator and power

unit is secure and connections are clean. Connection to

power  unit  should  be  tightened  1/4  turn  beyond  finger

tight.

5. If pilot still goes out, measure the open and closed

generator circuit output voltages. Compare to acceptable

range charts in the generator specifications or in the Gas

Controls Handbook. Replace the generator if voltages are

outside the acceptable range.

6. Check  power  unit  resistance.  If  above  11  ohms,

replace gas control.

CHECK SAFETY SHUTDOWN PERFORMANCE

WARNING

FIRE OR EXPLOSION HAZARD

CAN CAUSE PROPERTY DAMAGE, SEVERE IN-

JURY, OR DEATH

Perform the safety shutdown test anytime work is

done on a gas system.

1. Place  gas  control  knob  in  PILOT  position.

Main burner should go out and pilot should

remain lit.

2. Extinguish pilot flame. Pilot gas flow should

stop  within  2-1/2  minutes.  Safety  shutoff  of

pilot  gas  proves  complete  shutdown  since

safety shutoff valve blocks flow of gas to main

burner and pilot.

3. Relight pilot burner and turn gas control knob

to ON.

4. Set  thermostat  to  call  for  heat  and  observe

appliance through one complete cycle to make

sure it operates as intended.

IF  MAIN  BURNER  WILL  NOT  COME  ON  WITH  CALL

FOR HEAT

1. Make sure gas control knob is in the ON position.

2. Adjust thermostat several degrees above room tem-

perature.

3. Disconnect leadwires to lower left TH terminal and

lower right PP terminal to isolate valve operator coil from

balance of circuit. Measure resistance of coil. If coil is not 2

ohms 

±

10 percent, replace VS824A Valve Operator.

4. Measure the open and closed generator circuit out-

put voltages and compare to acceptable range charts in

the generator specifications or in the Gas Controls Hand-

book.  Replace  the  generator  if  voltages  are  outside  the

acceptable range.

IF BURNER IS OVERFIRING

Adjust pressure regulator to correct pressure. If regula-

tor cannot be adjusted and supply pressure is in normal

range, replace complete gas control.

6

Содержание VS820A

Страница 1: ...D Hi Low V5308A VS820P Step V5307B 40 to 175 40 to 79 VS820V Standard V5306A WARNING FIRE OR EXPLOSION HAZARD CAN CAUSE PROPERTY DAMAGE SEVERE IN JURY OR DEATH Follow these warnings exactly 1 Disconnect power supply before wiring to pre vent electrical shock or equipment damage 2 To avoid dangerous accumulation of fuel gas turn off gas supply at appliance service valve before starting installation...

Страница 2: ...able or 50 ft 15 3 m of 2 wire 16 gauge cable INLET AND OUTLET ADAPTERS If adapters are needed prepare control as follows 1 Remove seal over control inlet or outlet 2 Apply moderate amount of good quality pipe com pound to adapter leaving two end threads bare Refer to Fig 1 On LP installation use compound resistant to LP gas Do NOT use Teflon tape 3 Insert adapter in control and thread carefully u...

Страница 3: ... Figs 3 and 4 If tubing is used connect tubing to coupling CONNECT PILOT GAS TUBING 1 Cut tubing to desired length and bend as necessary for routing to pilot burner Do not make sharp bends or deform tubing Do not bend tubing at control after compres sion nut has been tightened as this may result in gas leakage at the connection 2 Square off and remove burrs from end of tubing 3 Unscrew brass compr...

Страница 4: ...out turn gas control knob clockwise to OFF Repeat steps 1 3 4 Release gas control knob If pilot remains lit turn counterclockwise to ON ADJUST PILOT FLAME Thepilotflameshouldenvelop3 8to1 2in 10to13mm of the tip of the generator Refer to Fig 9 Fig 9 Proper flame adjustment TURN ON MAIN BURNER Follow instructions provided by appliance manufacturer or turn up thermostat to call for heat CHECK AND AD...

Страница 5: ...eld adjustable The HI or LOW flame setting is selected by position ing the white knob on the regulator Refer to Fig 10 Fig 10 HI and LOW settings for VS820D 1 Check the LOW flame setting listed on the appliance nameplate Gas control LOW flame setting should match this rating 2 With main burner operating check gas control outlet flowrateusingthemeterclockingmethodoroutletpressure using a manometer ...

Страница 6: ...ge 4 b Compression fitting has a gas leak replace old compression fitting or tighten new one Refer to page 3 c Pilot burner tubing or orifice is clogged replace combination gas control Refer to page 1 IF PILOT GOES OUT WHEN GAS CONTROL KNOB IS RELEASED 1 Make sure the gas control knob is held in at least one minute to allow the generator time to heat 2 Check pilot flame adjustment refer to page 4 ...

Страница 7: ...ontrol knob all the way and hold in Immedi ately light the pilot with a match Continue to hold the control knob in for about one 1 minute after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 10 10 Replace pilot access panel 11 Turn gas control knob counterclockwise to ON 12 Replace control access panel 13 Turn on all electric power to th...