Honeywell VR8215N Скачать руководство пользователя страница 3

VR8215S,T SINGLE STAGE VR8215Q,N TWO STAGE DIRECT IGNITION GAS CONTROLS

3

69-2253—07

CAUTION

Equipment Damage Hazard.
Can burn out thermostat or transformer.

Applying a jumper across (or shorting) the 
valve coil terminals, even temporarily, can burn 
out the thermostat or transformer.

Follow the appliance manufacturers instructions if 
available; otherwise use these instructions as a guide.

IMPORTANT

These gas controls are shipped with protective 
seals over the inlet and outlet tappings. Do not 
remove the seals until ready to install adapters 
or connect the piping.

Install Bushings To Control

If bushings are being installed on the control, mount 
them as follows:

Bushings

1.

Remove the seal over the control inlet or outlet.

2.

Apply a moderate amount of good quality pipe 
compound to the bushing, leaving two end 
threads bare. On an LP installation, use 
compound that is resistant to LP gas. See Fig. 1.

NOTE:

 Do not use Teflon tape.

3.

Insert the bushing in the control and carefully 
thread the pipe into the bushing until tight. 

Complete the instructions below for installing the 
piping, installing the control, and connecting the 
wiring. Make sure the leak test you perform on the 
control after completing the installation includes leak 
testing the bushings.

Location

The gas controls are mounted in the appliance 
vestibule on the gas manifold. If this is a replacement 
application, mount the gas control in the same 
location as the old control.

Locate the combination gas control where it cannot be 
affected by steam cleaning, high humidity, or dripping 
water, corrosive chemicals, dust or grease 
accumulation or excessive heat. 

To assure proper operation, follow these guidelines:
• Locate gas control in a well-ventilated area.
• Mount gas control high enough above cabinet 

bottom to avoid exposure to flooding or splashing 
water.

• Assure the ambient temperature does not exceed 

the ambient temperature ratings for each 
component.

• Cover gas control if appliance is cleaned with water, 

steam, or chemicals or to avoid dust and grease 
accumulation.

• Avoid locating gas control where exposure to 

corrosive chemical fumes or dripping water are 
likely.

Install Piping to Control

All piping must comply with local codes and 
ordinances or with the National Fuel Gas Code (ANSI 
Z223.1, NFPA No. 54), whichever applies. Tubing 
installation must comply with approved standards 
and practices.

1.

Use new, properly reamed pipe that is free from 
chips. If tubing is used, make sure the ends are 
square, deburred and clean. All tubing bends 
must be smooth and without deformation.

2.

Run pipe or tubing to the control. If tubing is 
used, obtain a tube-to-pipe coupling to connect 
the tubing to the control.

3.

Install a sediment trap in the supply line to the 
control. See Fig. 2.

Install Control

1.

Can be mounted in any direction. 

2.

Mount so the gas flow is in the direction of the 
arrow on the bottom of the control.

NOTE:

Gas valve will leak if installed backwards. 

3.

Thread the pipe the amount shown in Table 5 for 
insertion into control or adapters. Do not thread 
pipe too far. Valve distortion or malfunction can 
result if the pipe is inserted too deeply.

4.

Apply a moderate amount of good quality pipe 
compound (do not use Teflon tape) only to the 
pipe, leaving two end threads bare. On LP 
installations, use a compound resistant to LP 
gas. See Fig. 1.

5.

Remove the seals over the control inlet and out-
let if necessary.

6.

Connect the pipe to the control inlet and outlet. 
Use a wrench on the hex end of the control. See 
Fig. 3.

Table 5.  NPT Pipe Thread Length.

a

a

 All dimensions are in inches (mm). 

b

 OK when bushings are used.

Fig. 1. Use moderate amount of pipe compound.

Pipe 

Size

Thread Pipe 

this Amount

Maximum Depth Pipe can be 

inserted into Control

3/8

b

9/16 (14)

3/8 (9)

1/2

3/4 (19)

1/2 (13)

TWO IMPERFECT 

THREADS

GAS CONTROL

THREAD PIPE THE AMOUNT 

SHOWN IN TABLE FOR 

INSERTION INTO GAS CONTROL 

APPLY A MODERATE AMOUNT OF

PIPE COMPOUND TO PIPE ONLY

(LEAVE TWO END THREADS BARE).

M3075B

PIPE

Содержание VR8215N

Страница 1: ... 6 4 mm SPECIFICATIONS Body Pattern Straight through see Table 1 for inlet and outlet size Electrical Ratings Voltage and Frequency 24 Vac 50 60 Hz Current Draw Single Stage 0 5 A Two Stage 0 9 A Field Wiring Single Stage Two 1 4 in spade quick connect terminals Two Stage Molex and spade quick connect terminals two 1 4 in and one 3 16 in Capacity See Table 1 Conversion Use conversion factors in Ta...

Страница 2: ... attack the control eventually causing a failure If chemicals are used for routine cleaning avoid contact with the control Where chemicals are suspended in air as in some industrial or agricultural applications protect the control with an enclosure Dust or Grease Accumulation Heavy accumulations of dust or grease can cause the control to malfunction Where dust or grease can be a problem provide co...

Страница 3: ...the ambient temperature ratings for each component Cover gas control if appliance is cleaned with water steam or chemicals or to avoid dust and grease accumulation Avoid locating gas control where exposure to corrosive chemical fumes or dripping water are likely Install Piping to Control All piping must comply with local codes and ordinances or with the National Fuel Gas Code ANSI Z223 1 NFPA No 5...

Страница 4: ... ignition coils HI Second stage or high fire 4 For single stage controls VR8215S T adjust thermostat heat anticipator to 0 50A rating stamped on valve label For two stage controls VR8215Q N adjust thermostat heat anticipator to 0 90A rating stamped on valve label Fig 4 Typical wiring connections for 24 volt control in S87 Direct Ignition System GAS CONTROL GAS CONTROL HORIZONTAL DROP PIPED GAS SUP...

Страница 5: ... burner is properly adjusted for complete combustion Follow appliance manufacturer instructions 2 IF CHECKING GAS INPUT BY CLOCKING GAS METER Make certain there is no gas flow through the meter other than to the appliance being checked Other appliances must remain off with the pilots extinguished or deduct their consumption from the meter reading Convert flow rate to Btuh as described in form 70 2...

Страница 6: ...afety Shutdown Performance WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Perform the safety shutdown test any time work is done on a gas system NOTE Read steps 1 through 7 before starting and compare to the safety shutdown or safety lockout tests recommended for the direct ignition DI module Where different use the procedure recommended for the ignition module 1...

Страница 7: ... of an unexpected shutdown would be high the system should be checked more often Dusty wet or corrosive environments Since these environments can cause the gas control to deteriorate more rapidly the system should be checked more often The system should be replaced if It does not perform properly on checkout or troubleshooting The gas control is likely to have operated for more than 200 000 cycles...

Страница 8: ...g spring 5 Insert the replacement spring See Fig 6 6 Install the new plastic pressure regulator adjust ment screw 7 Check the regulator setting using a manometer or by clocking the gas meter See Check and Adjust Gas Input and Burner Ignition on page 5 8 Adjust regulator by following the Single Stage Regulator Adjust ment process below 9 Reinstall the regulator cap screw 10 Mount conversion label o...

Страница 9: ...ting using a manometer or by clocking the gas meter See Check and Adjust Gas Input and Burner Ignition on page 5 8 Adjust high fire first by adjusting exterior 7 16 Hex After high fire has been set adjust low fire utilizing interior 3 32 allen See Fig 8 and the Two Stage Regulator Adjustment process below 9 Reinstall the plastic regulator cap 10 Mount conversion label on the gas control 11 Install...

Страница 10: ...e same measurement method to calibrate the low stage Two stage appliance operating sequences vary Consult the appliance manufacturer instructions for the specific operating sequence and for instructions on how to prevent the control from moving to high stage while calibrating the low pressure regulator setting 6 With the main burner operating on low fire cali brate the low fire regulator setting u...

Страница 11: ...requiring special instructions To Turn ON Appliance STOP Read the Warnings Above Before Proceeding 1 The lighting sequence on this appliance is automatic do not attempt to manually light the main burner 2 If the furnace does not come on when the thermostat is set several degrees above room temperature set the thermostat to its lowest setting to reset the safety control 3 Remove the burner access p...

Страница 12: ...rth Golden Valley MN 55422 3992 customer honeywell com U S Registered Trademark 2017 Honeywell International Inc 69 2253 07 M S Rev 04 17 Printed in United States WEEE Directive At the end of their useful life the packaging and product should be disposed of by a suitable recycling centre Do not dispose of with normal household waste Do not burn ...

Отзывы: