SYSTEM CONFIGURATION
70
ALARM NOTES
Free-form field for adding information about the alarm.
(i.e., “Door Status Monitor on Main Lobby Entry doors” OR
“Normally Closed contact activates Sequence 4 on
opening.”)
Steps for configuring an Alarm
1. From
the
Alarms
screen, select
General
.
2. Select
the
Alarm Number
to configure.
3. Enter
the
Alarm Description
(i.e., ALM 5 – Main Lobby Entry).
4. Check
the
Enabled
box to enable monitoring of the alarm.
5. To activate a sequence upon opening of the contact, check the
Contact Open
Enabled
box, assign a
Priority
and select/edit a
Sequence
.
6. To activate a sequence upon closing of the contact, check the
Contact Closed
Enabled
box, assign a
Priority
and select/edit a
Sequence
.
7. Enter pertinent notes regarding the alarm in the
Alarm Notes
field.
8. If the Alarm is in an Alarm Queue, associate a specific camera with this alarm by
checking the
Auto Sequence Enabled
box and selecting a camera using the drop
down box for either the
Camera Number
or
Camera Name
.
9. If the Alarm is in an Alarm Queue and a sequence is to be activated when the alarm
is acknowledged (Accepted), check the box to
Enable
the
Accept Sequence
function. Select a
Sequence
using the drop down box for either the
Sequence
Name
or
Sequence Number
.
10. If the Alarm is in an Alarm Queue and a message is to be displayed when an alarm is
activated, check the box to
Enable
the
Default Message
and select a
Message
using the drop down box for either
Message Name
or
Message Number
.
11. Select
to save/download all information from the current page.
Alarms Access
The
Alarms Access
tab is used to configure access to the alarms.
Содержание VideoBloX
Страница 1: ...800 04465 April 2008 Rev A VideoBloX Matrix Switcher User Manual ...
Страница 2: ...Revision History ISSUES DATE REVISIONS A Apr 2009 Initial Release ...
Страница 16: ......
Страница 55: ...Honeywell 39 Figure 2 56 SW 3 and SW 4 settings for interlink input module ...
Страница 163: ...Honeywell 147 ...
Страница 179: ...Honeywell 163 Note Device key codes please refer to command DEVICE ...