Honeywell
87
PTZ CONTROL TIMEOUT
Enabled
When enabled, sets a timeout for PTZ control after a period
of inactivity.
Timeout
Used to set the period of inactivity (in seconds) after which
PTZ control will be lost.
GENERAL <NO HEADING – FIELDS AT BOTTOM OF WINDOW>
Priority
Sets priority level for this keyboard. Priority can be set to a
number between 0 and 255 with 0 being the highest priority.
Steps for Configuring Keyboard Detail
1. On
the
Keyboards
screen, select the
Detail
tab on the right side of the window.
2. Select
the
Keyboard Number
to be configured.
5. Enter/edit
the
Keyboard
Name
. Include the keyboard number in the name entered as
it does not appear on its own in displays or reports.
6. Enter/edit
a
Short Name
for the keyboard.
7. Enter the physical
Address
of the keyboard.
8. Select the keyboard
Type
.
9. If this keyboard should automatically switch to a dedicated monitor, check the
Enabled
box and enter the physical address of the dedicated monitor in the
Physical O/P
field.
10. To run a sequence when a user logs in to this keyboard,
Enable
Login Sequence
and use either the Sequence Name or Sequence Number dropdown box to select the
Sequence to run. Edit the sequence as needed.
11. To run a sequence when a user logs out of this keyboard,
Enable
Logout Sequence
and use either the Sequence Name or Sequence Number dropdown box to select the
Sequence to run. Edit the sequence as needed.
12. To run a sequence when the keyboard establishes a connection,
Enable
the Connect
Sequence and use either the Sequence Name or Sequence Number dropdown box
to select the Sequence to run. Edit the sequence as needed.
13. To run a sequence when the keyboard connection is lost,
Enable
the Connect
Sequence and use either the Sequence Name or Sequence Number dropdown box
to select the Sequence to run. Edit the sequence as needed.
14. To automatically logout a user after a period of inactivity,
Enable
the Auto Logout.
T
hen select the
Auto Logout
time (in minutes).
15. To automatically timeout control of the PTZ after a period of inactivity,
Enable
the
PTZ Control Timeout, then select the
Timeout
period (in seconds).
16. Set the keyboard
Priority
with 0 indicating the highest priority.
17. Select
to save/download all information from the current page.
Содержание VideoBloX
Страница 1: ...800 04465 April 2008 Rev A VideoBloX Matrix Switcher User Manual ...
Страница 2: ...Revision History ISSUES DATE REVISIONS A Apr 2009 Initial Release ...
Страница 16: ......
Страница 55: ...Honeywell 39 Figure 2 56 SW 3 and SW 4 settings for interlink input module ...
Страница 163: ...Honeywell 147 ...
Страница 179: ...Honeywell 163 Note Device key codes please refer to command DEVICE ...