Installation Guide
8
69-2486—07
Setup functions
Settings & Options
(factory default in
bold)
0250
2nd stage heat
cycle rate (CPH)
9
Electric furnaces
1
Steam or gravity systems
3
Hot water systems & furnaces of 90%+ efficiency
5
Gas or oil furnaces of less than 90% efficiency
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH]
0260
3rd stage heat cycle
rate (CPH)
9
Electric furnaces
1
Steam or gravity systems
3
Hot water systems & furnaces of 90%+ efficiency
5
Gas or oil furnaces of less than 90% efficiency
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH]
0270
Emergency heat
cycle rate (CPH)
9
Electric emergency heat
1
Steam or gravity systems
3
Hot water systems & furnaces of 90%+ efficiency
5
Gas or oil furnaces of less than 90% efficiency
[Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH]
0280
Continuous
Backlight
0
Backlight on for approx. 45 seconds after keypress
1
Backlight always on low intensity, full bright after keypress
(requires 24VAC connection)
0300
Manual/Auto
changeover
0
Manual changeover (Heat/Cool/Off)
1
Automatic changeover (Heat/Cool/Auto/Off)
0310
Auto changeover
deadband
3
Heat/cool temperature 3°F apart (1.5°C)
[Other options: 2-9 (2°F to 9°F/1°C to 5°C)])
0320
Temperature
display
0 Fahrenheit
1
Celsius
0330
Daylight savings
1
Auto-change to daylight savings time (through 2007, and for
areas that do not use the new 2008 DST calendar)
0
Daylight savings time is turned off
0500
Furnace filter
change reminder
0 Off
1
10-day run time (about 1 month)
2
30-day run time (about 3 months)
3
60-day run time (about 6 months)
4
90-day run time (about 9 months)
5
120-day run time (about 1 year)
6
180-day run time (about 1.5 years)
7
270-day run time (about 2 years)
8
365-day run time (about 3 years)
9
30 calendar days
10 60 calendar days
11 90 calendar days
12 120 calendar days
13 180 calendar days
14 365 calendar days
0502
Furnace filter
for Run time
0
Counts both heat and cool
1
Counts cool only
0520
UV Lamp
Replacement
Reminder
0 Disabled
1
365 days
2
730 days
0530
Adaptive Intelligent
Recovery™
1
On
0 Off
Installer setup
Continued on next page