Fixing and cable breakaway tab 

Page 7 

INSTALLATION 

Fixing and cable breakaway tab 

Insert and fasten the power, data, and I/O cables in the connector (see Figure 
4 and Figure 5). If there is also a small grounding cable, use a cable clamp to 
connect it to the screw supporting the card. 

Anchor

Anchor

Breakaway tab
for cables exit
from bottom

Breakaway tab
for cables exit 
from back

 

Figure 4. Fixing and Breakaway tab 

Содержание temaline TK C12

Страница 1: ...TK C12 RTUK12 WEEE RoHS Compliant Directive 2002 95 EC Installation Manual ver 1 1 ...

Страница 2: ...0 LONWORKS Data Cables 10 INPUTs 12 Digital INPUTs 13 Supervised INPUTs 14 Power OUTs 15 Resistive load 16 Inductive load 16 Inductive load with external Power supply 17 External relays 18 Assembling the Terminal Closure Guide 19 Closing the Terminal Wall Mounted Assembly 20 Closing the Terminal Turnstile Mounted Assembly 21 Identification via the Service Pin 22 Identification via Bar Code 23 Tema...

Страница 3: ...ient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution any modification or change not expressly approved by the party responsible for compliance could void the user s authority t...

Страница 4: ...ELIMINARY OPERATIONS Mounting Instructions The cables are attached to an encased box Make sure that you place the box at a height of 120cm from the floor see Figure 1 tube cables 120 cm floor Figure 1 Space Requirements for Mounting ...

Страница 5: ...eps 1 Drill two holes into the wall to accommodate the plastic anchors that hold up the support plate you must use M4 screws 2 Make sure that the box attached to the wall is aligned with the niche on the lower part of the support plate 3 Use a 4mm slotted screwdriver Anchor Anchor Cables entrance Figure 2 Attaching the Support Plate ...

Страница 6: ...e bottom of the box see Figure 3 This alternative procedure consists of the following steps 1 Drill a hole in the breakaway tab and apply a cable clamp with a clutch for the cable tube 2 Remove the cable clamps from the rear side and apply the stopper Anchor Anchor PG9 cable clamp Multi pole cable 15 poles Figure 3 Channeling the Cables from the Bottom of the Box ...

Страница 7: ... power data and I O cables in the connector see Figure 4 and Figure 5 If there is also a small grounding cable use a cable clamp to connect it to the screw supporting the card Anchor Anchor Breakaway tab for cables exit from bottom Breakaway tab for cables exit from back Figure 4 Fixing and Breakaway tab ...

Страница 8: ...rs OUT2 OUT2 12V OUT1 OUT1 12V IN 1 IN 1 GND IN 2 IN 2 GND 12 V gro und NET A NET B J1 J3 J4 J2 Figure 5 Connectors Figure 6 Jumpers JP4 Î Buzzer ON OFF JP1 Î Close RFU JP2 Î Inputs Mode JP3 5 Î Outs NC NO LCD contrast regulation Trimmer BUZZER Tamper ...

Страница 9: ...ohm Km 150 mA 300 mA 600 mA 1 2 A 2 4 A 12 3 3 5 7 585 292 117 58 29 14 2 8 8 379 189 76 38 19 16 1 3 14 238 119 48 24 12 18 0 9 21 159 79 32 16 8 20 0 6 34 98 49 20 10 5 22 0 35 52 64 32 13 6 3 24 0 2 85 39 20 8 4 2 12V Ground When the cables go out of doors is mandatory to use shielded cables The cables shielding must be connected to the ground connector For internal wiring without shielded cabl...

Страница 10: ...a bus configuration the sum total of the sections must not exceed 2700m In a free topology configuration activate the 50ohm terminator by placing the appropriate jumper on the FTT10A plug in of the CTU PLG06 board inside the TemaServer In a bus configuration place two terminators with resistance values of 100ohm 1 W at the two ends of the bus 1 LONWORKS is a trademark of Echelon Corporation ...

Страница 11: ... 443 280 198 24 0 2 85 693 490 346 219 155 Table 1 Length Capacity of LONWORKS Data Cables m The FTT10A Echelon v1 2 User Guide recommends the cables indicated in Table 2 Producer and Model AWG Connection to bus maximum total length m Connection in free topology maximum node node length max m Connection in free topology maximum total wire length m Belden 85102 16 2700 500 500 Belden 8471 16 2700 4...

Страница 12: ...ct Usually the IN2 is dedicated to the push button request to exit However the inputs can be also used as general purpose inputs Mode select by JP2 JP2 Î Close Î Supervised inputs default Supervised inputs 4 status normal alarm cut short JP2 Î Open Î Digital inputs Digital inputs status open or Close Figure 7 JP2 position JP2 ...

Страница 13: ... cables shielding must be connected to the ground connector For internal wiring without shielded cables is recommended an electrical environment where the cables are well separated even at short runs especially to the power cables or external cables which can be essentially subjected to interference or lighting Use a twisted pair cable for the contact cables Make sure that the cables correspond in...

Страница 14: ...resistance 1210 Ohm When the cables go out of doors is mandatory to use shielded cables The cables shielding must be connected to the ground connector For internal wiring without shielded cables it is recommended an electrical environment where the cables are well separated even at short runs especially to the power cables or external cables which can be essentially subjected to interference or li...

Страница 15: ...the Busy lamp However the Outputs can be also used as general purpose outputs Mode NC NO select by JP 3 and JP4 JP3 Î 1 2 OUT 1 NO default 2 3 OUT 1 NC JP5 Î 1 2 OUT 2 NO default 2 3 OUT 2 NC Figure 10 JP3 and JP5 position Internally the output lines are provided with Power Mosfet that can drive to ground 1 2A 30V continuous 5A 30V 0 5 sec peak current for inductive loads JP3 1 2 JP5 1 2 3 2 1 ...

Страница 16: ... electrical environment where the cables are well separated even at short runs especially to the power cables or external cables which can be essentially subjected to interference or lighting Resistive load 12V OUT1 12V OUT2 max 1 2A max 1 2A 12VDC GND Figure 11 Connecting to resistive loads Inductive load 12V OUT1 max 1 2A 5A impulse 1N4004 12V OUT2 max 1 2A 5A impulse 1N4004 12VDC GND Figure 12 ...

Страница 17: ...2VDC GND 10 to 30VDC OUT2 1N4004 GND Isolated Power Supply Figure 13 Connecting to inductive loads with an external isolated power supply Note for inductive loads In this case is mandatory use the 1N4004 diodes as in figure Two 2 Diodes are included in the product The external power supply has to be isolated ...

Страница 18: ...s the max internal Mosfet current it is possible to use external relays 12VDC GND OUT1 OUT2 12V relay 12V relay 1N4004 1N4004 Figure 14 Relays OUT Notes Use 12VDC relay max coil current 100mA each In this case is mandatory use the 1N4004 diodes as in figure ...

Страница 19: ... 2 Insert the nut and the special screw into the corresponding niche on the guide see Figure 15 nut screw head Figure 15 Mounting the Terminal Closure Guide 1 Make sure that the fitting is correctly positioned and then insert the flat cable from the front casing into the connector see Figure 16 Figure 16 Mounting the Terminal Closure Guide 2 O ring Special screws Closure Guide NUT Special star sha...

Страница 20: ...e screw by turning it counterclockwise so that the terminal closure remains fully open in the direction of the wedge 2 Insert the upper shell as indicated in Figure 17 3 Fasten the special closure screw by turning it clockwise and pushing down on the shell so that the fitting is completely secure 4 Tighten the screw Figure 17 Closing the Terminal Wall Mounted Assembly ...

Страница 21: ...sure screw by turning it counterclockwise so that the terminal closure remains fully open in the direction of the wedge 2 Insert the upper shell as indicated in Figure 18 3 Fasten the special closure screw by turning it clockwise and pushing down on the shell so that the fitting is completely secure 4 Tighten the screw Figure 18 Closing the Terminal Turnstile Mounted Assembly ...

Страница 22: ...to activate the service pin This signal is linked to the yellow central service LED which flashes throughout the node configuration procedure 2 The TemaServer in response to the service pin sends a wink command that makes yellow LED flash three times This allows you to verify that communication to and from the TemaServer is working 3 Check that the service LED remains off after you have completed ...

Страница 23: ...is label to the corresponding identification form and indicate the location of the terminal in the appropriate box see example in Table 5 Description of location Office entrance area first floor staircase E Description of TemaServer Panel 2 entrance area first floor staircase E TKC01 RTU K01 TKC02 RTU K02 TKC03 RTU K03 TKC12 RTU K12 NID label Table 5 Example of Completed Identification Form X ...

Страница 24: ...Storage relative humidity 0 90 without condensation Display Alphanumeric 16x2 led backlight Acustic signal 1 Buzzer LED 1 led with 3 color RED Green Yellow Lon service Led Keyboard 4 x 4 keypad with soft epoxy UL treatment on keys for harsh environment Proxy receiver 13 56MHz for 14443A B cards Reading range depending on technology of card Typical 7 cm for MIFARE2 full ISO14443A Typical 4 cm for S...

Страница 25: ...ce 5Vdc Voltage 14V max 0V min Outputs Number 2 Type Power Open drain MOSFET Current 1 2A continuous 5A 0 5sec impulsive Voltage 10V 14V internal Power supply Voltage absolute max 10V 30V from external Power supply Current 1 2A 5A 0 5sec peak max inductive load Normality NO or NC via Jumper setting JP3 1 2 OUT 1 NO 2 3 OUT 1 NC JP5 1 2 OUT 2 NO 2 3 OUT 2 NC Wire length connection it depends on cab...

Страница 26: ...NWORKS 3 connection Unshielded twisted pair cable in free topology transceiver FTT10A 78Kbps Compliance with Regulations Directive EMC 89 336 EEC 92 31 EEC Directive Low Voltage 72 23 EEC 93 68 EEC EN60950 EN55024 EN55022 EN 300 330 Environment friendly RoHS WEEE compliant device Directives 2002 95 EC 2002 96 EC Optional Parts TORX screwdriver TX10 code 1500108AA 3 LONWORKS is a trademark of Echel...

Страница 27: ...ratus effective beginning 13 August 2005 Honeywell commits when requested by the customer to the collection treatment recovery and disposal of the apparatus produced Customers in European Union are advised to dispose this product at the end of its useful life as per applicable local laws regulations and procedures ...