Override Unoccupancy mode 

(MOON FLASHING) 

Occupancy mode display for Excel 10 LED 
signaling (Excel 10 set to LED_OCCUPANCY) 

 

Effective Bypass mode 

(SUN continuously ON) 

 

 

 

Effective Standby mode; generated by 

time program 

(HALF-SUN continuously ON) 

 

 

Off Conditions, Effective Unoccupancy 

mode 

(MOON continuously ON) 

 

 

Wink mode (NEURON

©

 ID sent) 

(SUN/MOON/SNOWFL. FLASHING) 

(Only with FCU, HYD, CHC) 

Occupancy mode display for Excel 20 to 600 

Display of the currently active Excel 20 to 600 mode; further 

options depend on the configuration of the controller: 

 

 

Occupancy mode 

(SUN continuously ON) 

 

 

 

Standby mode; generated by time 

program 

(HALF-SUN continuously ON) 

 

 

Unoccupancy mode 

(MOON continuously ON) 

 

 

 

To adapt the T7560 to the CARE control strategies for Excel 

20 to 600, a standard ModAL software module is available. 

Contact your local Honeywell distributor, or refer to 

T7560A,B,C Installation Instructions (product literature no.: 

EN1B-0146GE51) for further details. 

 

ACCESSORIES 

For mounting the following accessories, please refer to the 

T7560A,B,C Installation Instructions (product literature no.: 

EN1B-0146GE51). 

 

T7460-LONJACK 

The T7460-LONJACK is a small board and allows easy 

access to L

ON

W

ORKS

 via the wall module (the wall module 

must be already connected, in compliance with the max. 

cable lengths set forth by the L

ON

W

ORKS

 Guidelines, to the 

L

ON

W

ORKS

 network via a L

ON

W

ORKS

 bus cable). Via an 

additional 3.5 mm jack plug on the board, a PC connection 

can be established. 

 

Order quantity: 

set of 5 pieces 

T7560 Blinds 

Same material and color as housing; for covering non-

operational buttons. 

Order quantity: 

set of 50 pieces. 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание T7560B

Страница 1: ...hange configuration information such as the DWM s engineering units The T7560C Digital Wall Module see inset above has no user interface e g LCD buttons or setpoint dial and issues only temperature and humidity values These wall modules are not compatible with Honeywell W7751A C E G VAV1 and W7752D1 FCU1 Controllers FEATURES Fully compatible with all current Excel 10 and Excel 20 to 600 controller...

Страница 2: ...ominal re sistance Ω 15 5 0 29 31543 18 3 0 27 27511 21 1 0 27 24047 26 7 0 27 18490 29 5 0 29 16264 Humidity Sensor Table 3 Humidity sensor specifications parameter value humidity sensing range 5 95 r h output signal 0 5 10 Vdc 5 100 r h accuracy 5 full scale Fan Speed Button T7560A B only Table 4 Fan speed resistances switch position resistance Ω fan behavior auto 1681 4 100 runs as scheduled 0 ...

Страница 3: ... 3 4142 0 79 3053 0 4 3689 3 81 2509 3 5 3236 7 83 1965 6 6 2784 0 85 1421 9 7 2331 3 8 1878 7 9 1426 0 10 973 3 Field Wiring 16 to 22 AWG 1 5 to 0 34 mm2 depending on application 18 AWG 1 0 mm 2 min for 24 Vac power wiring Max length of wire from a device to a wall module is 164 ft 50 m Twisted pair wire recommended for wire runs longer than 100 ft 30 5 m Setpoint Adjustment Range A and B Setpoin...

Страница 4: ...n to decrease increase the room temperature setpoint The display toggles the setpoint value either relative or absolute as configured After the new setpoint has been set the display returns to normal mode after approx 5 sec Set Fan Speed The manually set fan speed is represented by a bargraph Depending on configuration the fan speed can be set as follows Three speed fan override AUTO OFF 1 2 3 Two...

Страница 5: ...ode MOON continuously ON Unit Off No Frost Protection OFF without snowflake Unit Off With Frost Protection OFF WITH SNOWFLAKE Override Standby mode from central HALF SUN FLASHING Wink mode NEURON ID sent SUN MOON SNOWFL FLASHING Only with FCU HYD CHC Press the BYPASS button to set the desired mode To activate Override Occupancy or Bypass mode press and release the BYPASS button To activate Overrid...

Страница 6: ...e further options depend on the configuration of the controller Occupancy mode SUN continuously ON Standby mode generated by time program HALF SUN continuously ON Unoccupancy mode MOON continuously ON To adapt the T7560 to the CARE control strategies for Excel 20 to 600 a standard ModAL software module is available Contact your local Honeywell distributor or refer to T7560A B C Installation Instru...

Отзывы: