T7147 REMOTE SENSOR AND OVERRIDE MODULE

63-4065—1

2

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the 
TRADELINE® Catalog or price sheets for complete ordering number.

If you have additional questions, need further information, or would like to comment on our products or services, please write or 
phone:

1.

Your local Home and Building Control Sales Office (check white pages of your phone directory).

2.

Home and Building Control Customer Relations
Honeywell, 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386 (800) 328-5111

In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, 
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.

SPECIFICATIONS

IMPORTANT

The T7147 is factory-calibrated. It does not require 
field calibration and cannot be field adjusted.

Models:
T7147A1002 Remote Temperature Sensor & Override 

Module: Connects to Q7300. Contains remote sensor, 
LED and push-button switch to invoke 3 Hour Occupied 
from remote location.

T7147A1010 Remote Temperature Sensor & Override 

Module: Connects to Q7300. Contains remote sensor, LED 
and 3 push-button switches to invoke 3 Hour Occupied and 
Warmer/Cooler setpoint adjustments from remote location.

T7147A1028 Remote Temperature Sensor & Override 

Module: Connects to Q7300. Same as T7147A1010 except 
includes key-lock switch to enable/disable remote override 
operation.

Mounting: Mounts on wall or 2 x 4 inch vertical outlet box with 

screws provided.

Dimensions: See Fig. 1.

Wiring:
Maximum cable length between T7300/Q7300 and T7147: 

500 ft (152 m); use 18, 20 or 22 AWG wire.

Temperature offset per 500 ft (152 m) of 2-wire sensor wire 

cable (1000 ft [305 m] total length): See Table 1.

Temperature Sensor: Thermistor-resistor (NTC) element.

Sensor Resistance:
Resistance decreases as temperature increases (Fig. 2).
1420 ohms nominal at 75°F (24°C); resistance changes 

15 ohms for each 1°F (0.6°C) temperature change.

Temperature Ratings:
Ambient: 40 to 110°F (4 to 43°C).
Shipping: -30 to +150°F (-34 to +66°C).

Humidity Ratings: 5 to 90% RH, non-condensing.

Accessories:
230492A Keys for T7147A1028.

Fig. 1. T7147 dimensions in in. (mm).

Table 1. Temperature Offset for Remote Sensor Wiring.

Fig. 2. T7174 Remote Sensor Resistance 

change with change in temperature.

Temperature Monitored

18 AWG

20 AWG

22 AWG

50 to 90°F

-0.4°F

-0.7°F

-1.0°F

10 to 32°C

-0.3°C

-0.4°C

-0.6°C

3-1/4

(83)

3-3/4

(96)

4-5/8
(117)

1-13/16 (46)

3-5/8 (92)

1-1/8 (29)

1-5/8 (41)

2-13/16 (71)

1/4

(6)

M17881

COOLER

3 HOUR

OCCUPIED

WARMER

NOT ALL MODELS HAVE WARMER/COOLER FUNCTION.

1

1

2000 

1800

1600

1400

1200

1000

10 

20

30

40

50

60 

70

80

90

100

RESISTANCE
(OHMS) 

1420 OHMS AT
     75 F (24 C)

TEMPERATURE (DEGREES) 

M4034

-10 

0 10 20 30 40 

 C

 F

Содержание T7147

Страница 1: ...ith the T7300 Q7300 Programmable Commercial Thermostat system The T7147 provides space temperature sensing switch initiation and indication of overrides from a remote location FEATURES Locking cover Override key Warmer Cooler keys on some models Key lock override security available Contents Application 1 Features 1 Specifications 2 Ordering Information 2 Installation 3 Wiring 4 Operation 6 Checkou...

Страница 2: ...tches to invoke 3 Hour Occupied and Warmer Cooler setpoint adjustments from remote location T7147A1028 Remote Temperature Sensor Override Module Connects to Q7300 Same as T7147A1010 except includes key lock switch to enable disable remote override operation Mounting Mounts on wall or 2 x 4 inch vertical outlet box with screws provided Dimensions See Fig 1 Wiring Maximum cable length between T7300 ...

Страница 3: ... unheated areas behind the thermostat wall Locate the T7147 about 5 ft 1 5 m above the floor in an area with good air circulation within easy reach of users Mounting 1 Loosen the cover locking screw with the Allen wrench provided and remove the T7147 cover 2 Run wire to the selected location 3 Thread wire through T7147 base semicircular hole 4 Make connections to T7147 see Wiring section 5 If air ...

Страница 4: ... subbase switch 5 local remote sensor select switch is in the OFF position Refer to the T7300 Q7300 Specification sheet form 63 4038 for details IMPORTANT The ground GND connection at the T7147 is required Use the junction box or conduit for a convenient grounding location 3 Ensure all connections are tight and secure Loose or intermittent wire connections cause inconsistent system operation 4 Whe...

Страница 5: ...LOCATION M10193 T7300 Q7300 T7147 C1 C2 C3 C4 C5 T T CA1 CA2 CA3 CA4 CA5 GND T T T T7300 Q7300 T T T T T T T T T T7047C2007 T7047C2007 T7047C2007 T7147A ONLY ONE T7417 ALLOWED PER SYSTEM SHIELDED CABLE CAN BE REQUIRED IN SOME INSTALLATIONS THE GROUND GND CONNECTION TO THE T7417 IS REQUIRED USE THE JUNCTION BOX OR CONDUIT FOR A CONVENIENT GROUNDING LOCATION 1 1 2 2 3 3 M10194 C1 C2 C3 C4 C5 T T CA1...

Страница 6: ...ur override This override may be performed at any time regardless of whether the thermostat system is operating in the occupied or unoccupied mode NOTES For additional details consult the T7300 Q7300 Specification sheet form 63 4038 Premature exit from either override can be achieved by pressing the 3 Hour Occupied key again The T7300 then returns to normal operation CHECKOUT 1 Allow the sensor to...

Страница 7: ...7 63 4065 1 ...

Страница 8: ...well Asia Pacific Inc Honeywell Europe S A Honeywell Latin American Honeywell Honeywell Limited Honeywell Limitée Room 3213 3225 3 Avenue du Bourget Region 1985 Douglas Drive North 35 Dynamic Drive Sun Hung Kai Centre 1140 Brussels 480 Sawgrass Corporate Parkway Golden Valley MN 55422 Scarborough Ontario No 30 Harbour Road Belgium Suite 200 M1V 4Z9 Wanchai Sunrise FL 33325 Hong Kong ...

Отзывы: