background image

2

T451A, T651A, T694A,B,D,F

SPECIFICATIONS • ORDERING INFORMATION

Specifications

SUPER TRADELINE MODEL

TRADELINE models are selected and packaged to provide

ease of stocking, ease of handling and maximum replace-
ment value. TRADELINE  model specifications are the
same as those of standard models except as noted below.

SUPER TRADELINE MODEL AVAILABLE:

T651A2028 Light Duty Line Voltage Thermostat.

FEATURES:

— Temperature scale range 35

°

 F to 95

°

 F.

— Spdt switch breaks heating contacts and makes cooling

contacts on temperature rise.

— Automatic cooling anticipator for 120, 208, 240 and

277 Vac.

— Vertical faceplate with Fahrenheit scale and ther-

mometer.

— Horizontal faceplate with Fahrenheit scale and ther-

mometer.

— Blank vertical faceplate.
— Blank horizontal faceplate.
— Wallplate.
— Adjustable range stops.
— Locking cover screw.

STANDARD MODELS:

Model

Changeover

Number

Application

System Switch

Switch

Fan Switch

T451A2007

a

Heating only.

T451A2015

Heating only with positive OFF.

T651A2028

a

Heating/cooling.

T694A2002

Heating/cooling. OFF position breaks

ON-OFF

HI-MEDIUM-LO

fan circuit.

T694B2001

Heating/cooling. OFF position breaks

ON-OFF

HEAT-COOL

HI-MEDIUM-LO

cooling and fan circuits.

T694D2009

Heating/cooling. Heating circuits isolated

ON-OFF

HEAT-COOL

HI-MEDIUM-LO

from cooling circuits. OFF position
breaks all control circuits except heat.

T694F2007

Heating/cooling. Heating circuits isolated

ON-OFF

HEAT-COOL

HI-MEDIUM-LO

from cooling circuits. OFF position breaks
all power to fan and thermostat.

a

With thermometer.

Ordering Information

When purchasing replacement and modernization products from your TRADELINE® wholesaler or your distributor, refer to the
TRADELINE Catalog or price sheets for complete ordering number, or specify—

1. Order number.
2. Accessories, if desired.
3. Order additional components and system accessories separately.

If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:

1. Your local Honeywell Home and Building Control Sales Office (check white pages of your phone directory).
2. Home and Building Control Customer Satisfaction

Honeywell Inc., 1885 Douglas Drive North
Golden Valley, MN 55422-4386 (612) 951-1000

In Canada—Honeywell Limited/Honeywell Limitee, 740 Ellesmere Road, Scarborough, Ontario M1P 2V9, International Sales and
Service offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico,
Netherlands, Spain, Taiwan, United Kingdom, U.S.A.

Содержание T451A

Страница 1: ...tches activated by bimetal sensor T451A T651Amountonstandardverticalorhorizon tal junction box Optionsincludeadjustablerangestops lockingcover concealedsetpoint lockingsetpoint positiveoffcon trol cover thermometer T451A provides heating control only T651A provides heating and cooling control T694A B D Fsuppliedwithswitchingsubbasetopro vide manual control of heating cooling and fan Q473A B switch...

Страница 2: ...oling and fan circuits T694D2009 Heating cooling Heating circuits isolated ON OFF HEAT COOL HI MEDIUM LO from cooling circuits OFF position breaks all control circuits except heat T694F2007 Heating cooling Heating circuits isolated ON OFF HEAT COOL HI MEDIUM LO from cooling circuits OFF position breaks all power to fan and thermostat a With thermometer Ordering Information When purchasing replacem...

Страница 3: ...RIES Q473A2006 Switching Subbase Use with T651A for HEAT OFF COOL manual system switching Q473B2005 Switching Subbase Use with T451A T652A for AUTO OFF switching in heating only or cooling only applications 220124A Faceplate vertical Fahrenheit scale with thermometer a 220124B Faceplate vertical Celsius scale with ther mometer 220124C Faceplate horizontal Fahrenheit scale with thermometer a 220124...

Страница 4: ... circulation at average room temperature Do not install the thermostat where it may be affected by drafts or dead spots behind doors and in corners hot or cold air from ducts radiant heat from sun or appliances concealed pipes and chimneys unheated uncooled areas behind the thermostat such as an outside wall WIRING AND MOUNTING Disconnect power supply before making wiring connec tions to prevent e...

Страница 5: ... OPTIONAL COVERS OLD T651A WALL MARKS WHEN INSTALLING NEW T651A T694A B D F THERMOSTATS Fig 5 All T694A B D F Thermostats mount vertically on a 2 x 4 in or 4 x 4 in junction box See Fig 5 Use 2 x 4 in cover plate with 4 x 4 in junction box 1 Before mounting connect system wiring to proper color coded leads at rear of thermostat Follow equipment manufacturer instructions or refer to Figs 6 9 for ty...

Страница 6: ...ig 6 T694A in heating cooling system with independent valve and fan circuits Fig 7 T694B connected for positive off switch ing in COOL position Fig 8 T694D with isolated switching for heating and cooling Fig 9 T694F with positive off position ...

Страница 7: ...en used in cooling applications with current draws that are more than four amps If a wider differential range is unacceptable use a T6051 Heavy Duty Line Voltage Thermostat for a smaller differential range T694 NOTE System switch must be in ON position to check out system 1 Close the disconnect switch if used and press HEAT switch adjust setpoint above room temperature and check that heating syste...

Страница 8: ...me and Building Control Helping You Control Your World Honeywell Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley MN 55422 Scarborough Ontario M1P 2V9 Printed in U S A QUALITY IS KEY ...

Отзывы: