Honeywell SILEN KNIGHT IDP-Zone-6 Скачать руководство пользователя страница 5

K200-16-00 

I56-2733-003

Figure 7: Relay control module used to disconnect a power supply.

9
8
7
6
5

4

3

2

1

0

ADDRESS

LOOP

RELAY

CONTROL

MODULE

(+)

(–)

FROM
PANEL OR
PREVIOUS
DEVICE

(+)

(–)

POWER LIMITED 
DC POWER SUPPLY,
LISTED FOR FIRE
PROTECTION
WITH BATTERY
BACKUP

(+)

(–)

TO NEXT

(+)

(–)

DEVICE

CONNECT MODULES

TO LISTED COMPATIBLE

CONTROL PANELS ONLY.

TWISTED PAIR

IS RECOMMENDED

(+)

(–)

SIGNAL LINE CIRCUIT (SLC)

32 VDC MAX.

C0248-01

C0142-01

—     +

—     +

+0

+1

IDC

ADDRESS

—     +

—     +

+2

+3

IDC

ADDRESS

—     +

—     +

+4

+5

IDC

ADDRESS

SLC

—     +

—     +

A/B SELECT

A/B SELECT

DISABLE 

1

DISABLE 

2

T6

T5

—     +

—     +

+0

+1

IDC

ADDRESS

—     +

—     +

+2

+3

IDC

ADDRESS

—     +

—     +

+4

+5

IDC

ADDRESS

SLC

—     +

—     +

A/B SELECT

A/B SELECT

DISABLE 

1

DISABLE 

2

T6

T5

IN

OUT

—     +

—     +

EXTERNAL SUPPLY

IN

OUT

—     +

—     +

EXTERNAL SUPPLY

EXTERNAL

POWER
SUPPLY

—        +

PCB 1

PCB 2

VIEW A-A

0

1

2 3 4 5

6

7

8

9

BASE 

ADDRESS

0

1

2 3 4 5

6

7

8

9

0

1

2 3 4 5

6

7

8

9

BASE 

ADDRESS

0

1

2 3 4 5

6

7

8

9

Figure 8: Example of multiple boards sharing same external supply. Refer to figures 8 and 9 for typical wiring. 

Make certain lip on long power supply jumper engages retaining tab on T5 or T6 as shown in View A-A.

Содержание SILEN KNIGHT IDP-Zone-6

Страница 1: ...0 2W B A SYSTEM SENSOR N A 20 2W TB A SYSTEM SENSOR N A 20 DH100LP A SYSTEM SENSOR N A 20 Class B Style B only No Accessory will be supported by 2100AT BEFORE INSTALLING If the modules will be installed in an existing operational system inform the operator and local authority that the system will be temporarily out of service Disconnect the power to the control panel before installing the modules ...

Страница 2: ...and wire the modules according to the instructions in this manual Included 5 1 x 4 Terminal Blocks 2 11 4 Stand offs 3 Shunts 4 Machine Screws 1 Long Power Supply Jumper 2 Nuts 6 3 9k Ohm End of Line Resistors Shipped on Board 2 Shunts in Class A B position Shipped in Class B position remove shunts for Class A COMPATIBILITY REQUIREMENTS To ensure proper operation this module shall be con nected to...

Страница 3: ...n Class B operation the remaining modules are automati cally assigned to the next five higher addresses For ex ample if the base address switch is set to 28 the next five modules will be addressed to 29 30 31 32 and 33 The module is shipped in Class B position remove shunts for Class A When operating in Class A alternate modules are paired together 0 1 2 3 4 5 re sulting in a total of three module...

Страница 4: ...long power supply jumper from T5 or T6 to T5 or T6 on the adjacent IDP Zone 6 module 0 1 2 3 4 5 6 7 8 9 BASE ADDRESS TO NEXT DEVICE STATUS INDICATORS 0 1 IDC ADDRESS 2 3 IDC ADDRESS 4 5 IDC ADDRESS SLC FROM PANEL OR PREVIOUS DEVICE CONNECT MODULES TO LISTED COMPATIBLE SILENT KNIGHT CONTROL PANELS ONLY SIGNAL LINE CIRCUIT SLC 32 VDC MAX SEE PANEL INSTRUCTION MANUAL FOR WIRE REQUIREMENTS CLASS A ID...

Страница 5: ... 0 1 IDC ADDRESS 2 3 IDC ADDRESS 4 5 IDC ADDRESS SLC A B SELECT A B SELECT DISABLE 1 DISABLE 2 T6 T5 0 1 IDC ADDRESS 2 3 IDC ADDRESS 4 5 IDC ADDRESS SLC A B SELECT A B SELECT DISABLE 1 DISABLE 2 T6 T5 IN OUT EXTERNAL SUPPLY IN OUT EXTERNAL SUPPLY EXTERNAL POWER SUPPLY PCB 1 PCB 2 VIEW A A 0 1 2 3 4 5 6 7 8 9 BASE ADDRESS 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 BASE ADDRESS 0 1 2 3 4 5 6 7 8 9 Figu...

Страница 6: ...tructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures R...

Отзывы: