DMG 973 AND SOCKET

DMG 973

ORDERING INFORMATION

ITEM

DESIGNATION

ITEM NO.

Control box

DMG 973 Mod. 01

0353001

Socket

Wiring base S98 12-pin

75310

Insert plate

PG-Plate

70502

optional

Cable entry plate

70503

Flame detector

IRD 1020.1 end-on

16532

Flame detector

IRD 1020.1 left

16533

Flame detector

IRD 1020.1 right

16531

optional

UVD 971

16722

Support for IRD

Holder M93 for IRD 1020

59093

Support for UVD

Holder M74 for UVD

59074

Connection cable

Plug type, 3 core cable, 0.6 m with tag wire ends

7236001

The above ordering information refers to the standard version.
Special versions are also included in our product range.

Specifications subject to change without notice

VARIATION IRD

right

left

axial

62,5

4,5

38,5

24

86

60

24

30

30

44

M4

Earth

Reset button

57-60

25

35

30

Underside cable
entry ø16 mm

16

Slide-in plate

UVD 971

IRD 1020.1

29

50

UVD = 29

IRD = 44

21,8

ø

13,5

UVD = 89

IRD = 104

29

21,8

HOLDER M 93 FOR IRD

35

3

14

4.5

26

15.1

48

17

ø20.5

4

HOLDER M 74 FOR UVD

ø 14

35

3

ø20

48

4,5

26

4

7

Содержание Satronic DMG 973

Страница 1: ...a variety of cable entry points utmost flexibility of electrical wiring The DMG 973 is funstionally compatible to MMI 813 and MMI 813 1 Please note Is the DMG 973 to be used to replace the MMI 813 or 813 1 care has to be taken to make sure the air proving switch LW is wired between terminals 4 and 7 and not like on the MMI between 5 and 7 DMG 973 Gas Burner Safety Control For 2 stage forced draugh...

Страница 2: ... short pulse long pulse short pause _ long pause 1 2 Lock out diagnoses In case of a failure the LED is permanently illuminated Every 10 seconds the illumination is interrupted by a flash code whichindicatesthecauseoftheerror Thereforethefollowing sequence is performed which is repeated as long as the unit is not reset Sequence illuminated phase dark phase Flash Code dark phase for 10 sec for 0 6 ...

Страница 3: ...trol box proceed to safety shut down and goes into a waiting status If the voltage rises again the control box performs automatically a start up as soon as the mains voltage is 187 Veff 94 Veff 5 Safety The design and control sequence of the DMG 970 controls will comply with the currently applicable standards and regulations see also TECHNICAL DATA 6 Burner with an air damper motor The position of...

Страница 4: ...switch LW contact is still in it s closed position e g welded contacts Has the air proving switch LW changed to it s open position in the meantime e g by a run down motor a normal start sequence follows 3 Fault finding The built in information system facilitates the trouble shoot ing in the case of problems occurring during start up or during operation A list of possible lock out messages can be f...

Страница 5: ...er motor tlw max reaction time for air proving switch tv1 Supervised pre purge time tlk LK open command during pre purge tr LK close movement tf Stray light monitoring tvz Pre ignition time tn Post ignition time ts Safety time tv2 Delay terminal 6 C rv1 rs 2 C 6 5 7 4 3 B 8 9 A rz rv2 Flame amplifier Reset µC Reset and lock out Power supply monitoring RZ RV1 RV2 RS Fault display Information system...

Страница 6: ...IRD Holder M93 for IRD 1020 59093 Support for UVD Holder M74 for UVD 59074 Connection cable Plug type 3 core cable 0 6 m with tag wire ends 7236001 The above ordering information refers to the standard version Special versions are also included in our product range Specifications subject to change without notice VARIATION IRD right left axial 62 5 4 5 38 5 24 86 60 24 30 30 44 M4 Earth Reset butto...

Отзывы: