69-0845—2
9
S8910U UNIVERSAL HOT SURFACE IGNITION MODULE
Fig. 3. Typical hookup when S8910U replaces White-Rodgers 50E/F47.
MV
MV
L1
(HOT)
L2
1
2
1
2
3
4
4
5
4
6
3
COMBINATION
GAS CONTROL
S8910U HOT SURFACE IGNITER CONTROL
HOT
SURFACE
IGNITER
FLAME
SENSOR
LIMIT
CONTROLLER
THERMOSTAT OR
CONTROLLER
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
MAKE SURE L1 AND L2 ARE NOT REVERSED.
ALTERNATE LIMIT CONTROLLER LOCATION.
REMOVE JUMPER QUICK-CONNECT FROM S8910U. CUT WIRE AT CIRCUIT BOARD AND DISCARD.
USE ADAPTER PLUG WITH BLACK AND ORANGE WIRES (SUPPLIED).
CUT 3/16 IN. QUICK-CONNECT OFF WIRE AND REPLACE WITH 1/4 IN. QUICK-CONNECT (SUPPLIED).
CUT 3/16 IN. QUICK-CONNECT OFF WIRE AND REPLACE WITH 3/16 IN. QUICK-CONNECT (SUPPLIED).
BURNER
GROUND
M8528B
AUTO IGNITION
SYSTEMS
ANSI Z21.20
S T A T U S L E D :
1 . F l a s h - I g n i t i o n L o c k o u t
2 F l a s h - W e a k F l a m e S i g n a l
3 F l a s h - I n t e r n a l E r r o r - R e p l a c e C o n t r o l
P u l s i n g " H e a r t b e a t " - N o r m a l O p e r a t i o n
S8910U HOT SURFACE IGNITION
INPUT VOLTAGES = 120 & 24 VAC, 60HZ
HSI = 120V, 6.5A MAX
VALVE = 24V, 1A MAX TOTAL 24V LOAD = 0.2 + VALVE LOAD
120VAC
HOT
570A0056
WARNING
!
Explosion hazard. Can cause
serious injury or death.
This device can malfunction if
it gets wet. Never try to use a
device that has been wet -- replace it.
GND
(BURNER)
24V
(GND)
VALVE
(GND)
24V
LED
L2
HSI
L1
HSI
SENSE
VALVE
MPLS., MN 55422
SEE
INSTRUCTIONS
FOR REMOTE
SENSE/DUAL
ROD
APPLICATIONS
TRIAL TIME,
NUM. OF TRIALS
CONFIGURATION
PLUG
120VAC
NEUTRAL
P r e p u r g e T i m e = 3 0 S e c
I g n i t e r W a r m u p T i m e = 3 4 s e c
ADAPTER
ORANGE
BLACK
6
TERMINAL CROSS
REFERENCE
S8910U
GND(BURNER)
24V (GND)
VALVE (GND)
24V
VALVE
L2
L1
HSI
HSI
SENSE
50E/F47
GND
TR
MV (NEXT TO TR)
TH
MV
—
L
—
IGN
FP
5
4
4