RLV431
69-2073EF-1 2008-01-29 1/4
RLV431
User Guide
Programmable Thermostat
The RLV431 thermostat can be used to control an electric heating
system such as a baseboard heater, a radiant floor, a radiant ceiling,
a convector, a fan-forced heater, etc.
The thermostat cannot be used with the following:
•
a resistive load under 2 A
•
a resistive load over 12.5 A
•
systems driven by a contactor or a relay (inductive load)
•
central heating systems
SUPPLIED PARTS
•
One (1) thermostat
•
Two (2) 6-32 mounting screws
•
Two (2) solderless connectors
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK.
All cables and connections must comply with local electrical
codes.
This thermostat has tinned copper wires for line and load con-
nections. Special CO/ALR solderless connectors must be used if
these wires will be connected to aluminum conductors.
Install the thermostat onto an electrical box.
Install the thermostat about 5 feet high, on an inside wall facing
the heater.
Avoid locations where there are air drafts (such as the top of a
staircase or an air outlet), dead air spots (such as behind a
door), or direct sunlight.
Do not install the thermostat on a wall that conceals chimney or
stove pipes.
The thermostat wires are not polarized; either wire can be con-
nected to the load or to the power supply.
n
Connect the thermostat using solderless connectors for copper
wires.
o
Secure the thermostat to the electrical box using the provided
screws. Insert the screws through either the right or left pair of
mounting holes on the thermostat.
p
If there is a protective film or sticker on the thermostat’s screen,
peel it off.
q
Apply power to the heating system.
r
Verify the installation by checking that the heater can be turned
On and Off by raising and lowering the setpoint using the
Up
and
Down
buttons.
WARNING: Keep the thermostat's air vents clean and free from
obstructions.
n
Description
1.
Period no. in
Automatic mode
Temperature
Heating power
indicator
Time and day
Manual
mode
Automatic
mode
Economy
mode
Setting no. in
Economy mode
Appears during
a power failure
Appears when the
setpoint is displayed
Flashes when the
clock has been reset
Appears if the
thermostat is configured
for a fan-forced heater
Display
NOTE:
To access the programming keypad, remove the cover by placing
your fingers to the right edge of the thermostat and pulling it.
Up/Down buttons
Mode button
Day button
Hour button
Program button
Return button
Reset opening
Minute button
o
Installation
2.
120/240
Vca
120/240
Vca
Solderless connector
for copper wires
Electric baseboard
2-wire installation
4-wire installation
Solderless connector
for copper wires
Electric baseboard
400-102-002-B_69-2073EF-1 (Honeywell RLV431) ENG.fm Page 1 Tuesday, January 29, 2008 10:12 AM