Owner’s Guide
14
During a power outage, the thermostat display remains lit for the first 2 minutes.
During this time, the
LP
(low power) indicator appears and all buttons are dis-
abled. Then the screen turns blank. The settings are stored in memory. When
power returns, the thermostat returns to the mode of operation preceding the
power outage. If the power failure has exceeded 5 hours, the clock and date must
be re-adjusted.
Supply
: 120/240 V AC, 60 Hz
Minimum load
:
1.25 A (resistive only)
300 W @ 240 V AC
150 W @ 120 V AC
Maximum load
:
14.6 A (resistive only)
3500 W @ 240 V AC
1750 W @ 120 V AC
Display range
: 0°C to 50.0°C (32°F to 99°F)
Setpoint range
: 5.0°C to 30.0°C (41°F to 86°F)
Resolution
: 0.5°C (1°F)
Storage temperature
: -20°C to 50°C (-4°F to 120°F)
Approval
:
Power outage
Specifications