14
www.honeywell.com
PW6K1R1E Wiring and Setup
Specifications
Reader data (RS-
485)
• 24AWG
• 120-ohm impedance
• Twisted pair with shield
• 4000-foot (1,219 m) maximum
Environmental
Temperature
• -55°C to +85°C, storage
• -40°C to +75°C, operating
Humidity
• 10 to 95% RHNC
Mechanical
Dimension
• 5.5" (140mm) W x 2.75" (70mm) L x 0.96"
(24mm) H without bracket
• 5.5" (140mm) W x 3.63" (92mm) L x 1.33"
(34mm) H with bracket
Weight
• 4.2 oz. (120g) without bracket
• 5.3 oz. (150g) with bracket
Enclosure
Box type
• The unit must be installed within a UL 514A/UL
514C Listed (QCIT or QCMZ) 3-gang electrical
box.
Box dimensions
• The minimum dimensions for the electrical box
are 2.75 inches by 2.75 inches by 5.8 inches, with
a minimum capacity of 44 cubic inches.
Box spacing
• Minimum spacings must be enforced of at least 1/
2 inch between the PWB/components and the
enclosure.
Tamper switch
• For UL applications, a tamper switch must be
installed.