- 21 -
Locate the cursor on
ALARM
item in the main menu and push the joystick to the right for
ALARM
programming of the camera.
Alarm Setup
No Fun Pri In Out Hld Latch
01 001 3 OFF OFF 001 OFF
02 002 3 OFF OFF 001 OFF
03 003 3 OFF OFF 001 OFF
04 004 3 OFF OFF 001 OFF
Save And Exit
No
: Alarm input number
Fun
: Priority 1~8calls Preset(xxx),
: Priority 0 supports dedicated functions like a Pattern(Pxx), Tour(Txx), Scan(Sxx).
Pri(Priority)
: Lower No. has higher priority, Equal priority alarms will be serviced repeatedly.
In
: NO/NC - normally open /Closed, OFF - ignore
Out
: RO1 - Relay out 1, RO2
– Relay out2 OFF - No output.
Hld(Hold)
: Alarm will be held for programmed time (01 to 255 seconds)
Latch
: ON - Shows all alarms including past alarm, OFF - Shows activated alarms only.
There are 9 levels of priority. 0 : Highest priority supports repeated/dedicated functions like a
Pattern(Pxx), Tour(Txx), Scan(Sxx). 1~8: Same level of alarm calls presets one after the other.
Program and Operation
2. ALARM
Main Menu
Function
Alarm
Screen
Camera
Setup
Password
Communication
Run Function
Exit
ENG