NetAXS™ Standalone Operation
NetAXS Panel Defaults
4.3 Reader Tamper Inputs
The card readers have a Tamper signal wired to the NetAXS™ panel. This is a
two-state input configured as a Normally Closed contact.
The following are the default Reader Tamper Input to Panel Input associations:
4.4 Door Egress Inputs
The panel has a Request-To-Exit (egress) input for each door. The default condition is
a two-state input configured as Normally Closed contact. When the egress input is
active, the associated output relay will be active.
The following are the default egress input associations:
Tamper LED
Reports as...
Tamper 1
Input 9
Tamper 2
Input 10
Tamper 3
Input 11
Tamper 4
Input 12
Egress input
Controls relay...
Panel input
Reports as...
1
1
SP1
Input 1
2
2
SP3
Input 3
3
3
SP5
Input 5
4
4
SP7
Input 7
Содержание NETAXS NX4L1