NetAXS™ NX4L1 Installation Guide
Installation
NetAXS™ NX4L1 Access Control Unit Installation Guide
,
Document 7-901099V3
31
The following figure shows the power distribution board field wiring.
Figure 9: Power Distribution Board Field Wiring
NetAXS
Circuit Board
CONTROL
OUTPUT
RELAYS
NX4L1
ENCLOSURE
FIELD WIRING
FACTORY WIRING
FACTORY WIRING
NETAXS RELAY N.O. TO POWER
DISTRIBUTION BOARD INPUT GND.
NETAXS RELAY COM TO POWER
DISTRIBUTION BOARD INPUT #.
FIELD WIRING
DEVICE COMMON TO POWER
DISTRIBUTION BOARD NEG #.
DEVICE POWER TO POWER
DISTRIBUTION BOARD RELAY # N.C.
(FAIL SAFE) OR N.O. (FAIL SECURE)
TERMINAL.
LOCATE S-4 SUPPRESSOR CLOSE
TO THE FIELD LOAD.
FIELD WIRING
FROM EXTERNAL
FIRE ALARM
CONTROL PANEL
DOOR LOCK,
STRIKE OR
OTHER FIELD
DEVICE
POWER
DISTRIBUTION
BOARD
1 NC
1 COM
1 NO
2 NC
2 COM
2 NO
3 NC
3 COM
3 NO
4 NC
4 COM
4 NO
8 NO
8 COM
8 NC
7 NO
7 COM
7 NC
6 NO
6 COM
6 NC
5 NO
5 COM
5 NC
IN 1
IN GND
IN 2
IN GND
IN 3
IN GND
IN 4
IN GND
IN 5
IN GND
IN 6
IN GND
IN 7
IN GND
IN 8
IN GND
OUT 1 NC
OUT 1 COM
OUT 1 NO
NEG #1
OUT 2 NC
OUT 2 COM
OUT 2 NO
NEG #2
OUT 3 NC
OUT 3 COM
OUT 3 NO
NEG #3
OUT 4 NC
OUT 4 COM
OUT 4 NO
NEG #4
OUT 5 NC
OUT 5 COM
OUT 5 NO
NEG #5
OUT 6 NC
OUT 6 COM
OUT 6 NO
NEG #6
OUT 7 NC
OUT 7 COM
OUT 7 NO
NEG #7
OUT 8 NC
OUT 8 COM
OUT 8 NO
NEG #8
FIRE PANEL IN+
FIRE PANEL IN
í
CNTRL+
CNTRL
í
DC
POWER
SUPPLY
+ DC
í
DC
Use either
N.C. or N.O.
relay
connection
COMMON
LOCK
CONTROL
VOLTAGE
S-4
(This feature has not
been evaluated by UL)