Scale Calibration Procedure (lbs. or kg) with Remote Display
7. Make sure there is no load on the scale platter.
8. Calibrate a zero load. Press the right arrow (
►
) button once when the remote display reads CAL 1 and
there is no load on the scale platter.
Figure 42.
9. Place a half load (15.00 lbs. or 7.500 kg) on the center of the scale platter then press the right arrow (
►
)
button.
Figure 43.
10. Add an additional half load (15.00 lbs. or 7.500 kg) to the existing half to simulate a full load, center entire
load then press the right arrow (
►
) button.
Figure 44.
11. Remove half of the load (15.00 lbs. or 7.500 kg), center the remaining load then press the right arrow (
►
)
button.
Figure 45.