U s e r I n s t r u c t i o n s - E n g l i s h
14
Total Fall Clearance Required for
one or two workers
connected to system
with Miller self-retracting lifeline (SRL) or
Miller rope grab and vertical lifeline.
Span
Length
(in Feet)*
1 Worker 2 Workers
0-10
(0-3m)
14’-1”
(4.29m)
14’-1”
(4.29m)
11-20
(3.4-6.1m)
14’-8”
(4.47m)
14’-9”
(4.5m)
21-30
(6.4-9.1m)
15’-3”
(4.65m)
15’-8”
(4.78m)
31-40
(9.4-12.2m)
15’-10”
(4.83m)
16’-7”
(5.05m)
41-50
(12.5-15.2m)
16’-5”
(5m)
17’-7”
(5.36m)
51-60
(15.5-18.2m)
17’-1”
(5.18m)
18’-7”
(5.66m)
TECHLINE HLL SYSTEM w/ RA-30 ROOF ANCHORS
FALL CLEARANCE TABLES
Total Fall Clearance Required for
one worker
connected to system
with Miller shock-absorbing lanyard.
Span
Length
(in Feet)*
Length of Lanyard
(in Feet & Inches)
3
(0.9m)
6
(1.8m)
0-10
(0-3m)
19’-1”
(5.82m)
22’-1”
(6.73m)
11-20
(3.4-6.1m)
19’-8”
(5.99m)
22’-8”
(6.91m)
21-30
(6.4-9.1m)
20’-3”
(6.17m)
23’-3”
(7.11m)
31-40
(9.4-12.2m)
20’-10”
(6.35m)
23’-10”
(7.26m)
41-50
(12.5-15.2m)
21’-5”
(6.53m)
24’-5”
(7.44m)
51-60
(15.5-18.2m)
22’-1”
(6.73m)
25’-1”
(7.65m)
Total Fall Clearance Required for
two workers
connected to system
with Miller shock-absorbing lanyards.
Span
Length
(in Feet)*
Length of Lanyard
(in Feet & Inches)
3
(0.9m)
6
(1.8m)
0-10
(0-3m)
19’-1”
(5.82m)
22’-1”
(6.73m)
11-20
(3.4-6.1m)
19’-9”
(6.02m)
22’-9”
(6.93m)
21-30
(6.4-9.1m)
20’-8”
(6.3m)
23’-8”
(7.21m)
31-40
(9.4-12.2m)
21’-8”
(6.6m)
24’-8”
(7.52m)
41-50
(12.5-15.2m)
22’-7”
(6.88m)
25’-7”
(7.8m)
51-60
(15.5-18.2m)
23’-7”
(7.19m)
26’-7”
(8.1m)
Total Fall Clearance Required for
one or two workers
connected to system
with Miller self-retracting lifeline (SRL) or
Miller rope grab and vertical lifeline.
Span
Length
(in Feet)*
1 Worker 2 Workers
0-10
(0-3m)
19’-1”
(5.82m)
19’-1”
(5.82m)
11-20
(3.4-6.1m)
19’-8”
(5.99m)
19’-9”
(6.02m)
21-30
(6.4-9.1m)
20’-3”
(6.17m)
20’-8”
(6.3m)
31-40
(9.4-12.2m)
20’-10”
(6.35m)
21’-7”
(6.58m)
41-50
(12.5-15.2m)
21’-5”
(6.53m)
22’-7”
(6.88m)
51-60
(15.5-18.2m)
22’-1”
(6.73m)
23’-7”
(7.19m)
*Span Lengths are provided in feet (meters); for lengths that fall between the span length ranges provided, round up or down to
the nearest span length using standard rounding rules. (Ex.: For 30’-5”, use the span length of 31-40 feet to determine required
fall clearance. For 50’-2”, use the span length of 41-50 feet to determine required fall clearance.)
Содержание Miller Techline HLLR Series
Страница 1: ...I254 Rev D MFP9720128 22 April 2013 ...