8
USE
Connection :
• The retractable type fall arrester can be connected to a reliable anchorage
point by its handle or by a connector, a fibre-type sling compliant to the
applicable standards EN 362 & EN 795.
• The connector with the permanent integrated swiveling element must be
connected to the fall arrest anchorage point of the harness (except specific
mention specified by the manufacturer for models equipped with Scafhook).
REMINDER
MODELS EQUIPPED WITH SCAFHOOK ARE INTENTED TO BE ATTACHED
BY THIS BIG OPENING CONNECTOR DIRECTLY TO THE STRUCTURE
(ANCHOR POINT) - DO NOT CONNECT THIS ONE TO THE HARNESS
ATTENTION
DO NOT ATTACH THE CONNECTOR OF THE FALL ARRESTER TO OTHER
POINTS THAN THOSE INTENDED FOR THIS SYSTEM - DO NOT ATTACH IT
DIRECTLY TO THE WEBBING ON THE ADJUSTMENT ELEMENTS OR ON
THE ACCESSORY HOLDER - THE “D“ BACK ANCHORAGE POINT OF THE
HARNESS IS THAT WHICH WILL ALLOW, IN THE CASE OF A FALL, THE BEST
POSITIONING (PICTURE 1.4 – RECOMMENDED USE)
Limits of use (except in special cases see specific manual):
• Temperature of use : from -30°C to + 50°C (Picture 1.6)
• Must always be placed above the user (Picture 1.7)
• Limit of pendular movement inferior to 30° (Picture 1.8)
• Can not stop a sinking (pulverulents or muddy products) (Picture 1.9)
Precautions of use :
• Check that the height of the anchorage point above the work space is
compatible with the capacity of the fall arrester and that sufficient clearance
exists, which is compatible with the characteristics of the device in the case
of a fall.
• Check that during use, the cable or the webbing does not get wound around
an arm or a leg.
• Never try to modify or to repair PPE; Only the manufacturer or a certified
maintenance centre is authorised to repair it.
• Never connect more than one person to the fall arrester.
• Never block the winding out of the cable, strap.
• The cable or the strap must always be tensed. In case of “slack”, the
equipment must be checked by the manufacturer.
• Lateral movements mustn’t exceed one third of the distance ground /
working surface.
• Make your movements on a normal walking speed. Accelerations, climbs
and others engage the clamping system of the equipment.
This equipment is designed for a vertical use. If your cable drum has been
designed for a special use (horizontal or inclined) you must follow the
recommendations of the additional specific instruction.
AIR CLEARANCE
Before using a cable drum, check for a minimum space clearance below the user’s
feet as necessary, to prevent any collision with the structure or the ground. With a
weight up to 136 kg in a normal use (cable drum above the head), the air clearance