Intrinsically Safe Marking
Cl. I, Div. 1, Gr A, B, C, D T4
Ta = -40° C to +50° C
IECEx SIR 18.0066X
Sira 18ATEX2251X
II Ex ia IIC T4 Ga
IM1 Ex ia I Ma
2460
Ui = 3.6V, Ci=78
µ
F, Li/Ri=3.5
µ
H/ohm
WARNING!
Substitution of components may impair suitability for intrinsic safety. Replace batteries only in
non-hazardous locations.
WARNING!
To prevent ignition of flammable or combustible atmospheres, disconnect power before
servicing.
Hazardous Areas Classified By Zones
Mesh Router is intended to be used in hazardous areas or mines susceptible to firedamp
classified zone 0, zone 1 or zone 2, within the temperature range of -40º C to +50º C, where
gases of explosion groups IIA, IIB or IIC and T4 may be present.
Hazardous Areas Classified By Divisions
Mesh Router is intended to be used in hazardous areas classified for Class I Div. 1 or 2, within
the temperature range of -40º C to +50º C, where gases of explosion groups A, B, C or D and
temperature class T4 may be present.
Instruction For Safe Use
Strictly follow the instructions for safe use. Application of the Mesh Router requires full
understanding and strict observation of the instructions.
Mesh Router
8
User Manual
Содержание Mesh Router
Страница 1: ...Honeywell Mesh Router Wireless Range Extender and Deployment Tool ...
Страница 2: ......
Страница 5: ......
Страница 11: ......
Страница 13: ...Mesh Router 13 User Manual ...
Страница 17: ......
Страница 20: ......
Страница 26: ......
Страница 28: ......
Страница 52: ......
Страница 58: ......
Страница 60: ......
Страница 71: ...Rev F Monday August 15 2022 User Manual P N F04 4002 000 Mesh Router 71 User Manual ...