- 7 - 

WEEKL

Y TESTING 

IS

REQ

UIRED T

O

 ENSURE

PR

OPER OPERA

TION

OF THIS 

SYSTEM

PO

WER SHUTDO

WN NO

TE:

 

A

T

 6.0VDC 

THE SYSTEM 

WILL NO

T OPERA

TE.

PREMISES

TELEPHONE

SOUNDERS

PLCD

AC

K10145X10 PLUG-IN

TRANSFORMER

9V

A

C

, 25V

A

EAR

TH

GR

OUND

INCOMING

TELEPHONE

LINE

T

O

 24HR 110V

A

C

UNSWITCHED

OUTLET

T

O

 24HR 110V

A

C

UNSWITCHED

OUTLET

PIEZO

6-14VDC

120mA max.

(e

.g.

 W

A

VE2EX)

6-14VDC

30mA max.

AC

AC

SYNC

COM

D

ATA

BELL

07000-016-V2

THIS DEVICE COMPLIES 

WITH P

A

R

T

 15 OF FCC R

U

LES

.

OPERA

TION IS SUBJECT 

T

O

 THE FOLLO

WING 

TW

O

CONDITIONS:

 (1) 

THIS DEVICE MA

Y NO

T CA

USE

HARMFUL INTERFERENCE, AND (2) 

THIS DEVICE MUST

A

CCEPT ANY INTERFERENCE RECEIVED

, INCLUDING

INTERFERENCE 

THA

T MA

Y CA

USE UNDESIRED

OPERA

TION.

THIS EQ

UIPMENT SHOULD BE INST

ALLED IN

A

CCORD

ANCE 

WITH 

THE NA

TIONAL FIRE PR

O

TECTION

ASSOCIA

TION ST

AND

A

RDS ANSI/NFP

A 70 NA

T

ONAL

ELECTRIC CODE AND NFP

A

 72 NA

TIONAL FIRE ALARM

CODE, CHAPTER 2 (NA

TIONAL FIRE PR

O

TECTION ASSOC

.,

BA

TTER

YMARCH P

A

RK, Q

U

INCY

, MA 02269).

 PRINTED

INFORMA

TION DESCRIBING PR

OPER INST

ALLA

TION,

EV

A

C

U

A

TION PLANNING AND REP

AIR SER

VICE IS 

T

O

 BE

PR

O

VIDED WITH 

THIS 

EQ

UIPMENT

.

X10 ONL

Y

CONNECTIONS

FCC ID:

 CFS8DLL

YNXREN-6

(L

YNXR-I) COMPLIES 

WITH

FCC R

U

LES

, P

A

R

T

 68 FCC

REGISTRA

TION

No

. 5GB

USA-25623-AL-E

RINGER EQ

UIV

ALENCE:

 0.6B

NO

TE

USE ONL

THE K10145X10

OR K10145CN CLASS 2

TRANSFORMERS

PR

O

VIDED

L

YNXR-I SUMMAR

Y OF CONNECTIONS

LY

NXR-I ALSO COMPLIES 

WITH 

THE FOLLO

WING:

CANADIAN ST

AND

A

RDS ASSOCIA

TION (CSA)

C22.1, CANADIAN ELECTRICAL CODE, P

A

R

T

 1,

SAFETY ST

AND

ARD FOR ELECTRICAL

INST

ALLA

TIONS AND CAN/ULC-S540

INST

ALLA

TION OF RESIDENTIAL FIRE

W

A

RNING SYSTEMS

.

THE L

Y

NXR-I CONTR

O

L IS COMP

A

TIBLE 

WITH

THE FOLLO

WING INTEGRAL RECHARGEABLE

BA

TTER

Y P

A

CKS:

EXTERNAL SOUNDERS

AND PO

WERLINE

CARRIER DEVICES HA

VE

NO

T BEEN EV

ALU

A

T

ED

BY UL.

FUTURE USE

GND

REPLA

CE EVER

Y FOUR 

YEARS

P/N L

YNXRCHKIT

-SC

P/N L

YNXRCHKIT

-HC

P/N L

YNXRCHKIT

-SHA

*WHEN AVAILABLE

1 2 3 4

BLACK

RED

YELLOW

GREEN

PL513

PO

WERLINE

INTERF

A

C

E

(IF USING

X10 DEVICES)

4-WIRE MODULAR PHONE

CORD 

WITH FL

YING LEADS

K10145CN

PLUG-IN

TRANSFORMER

9V

A

C

, 25V

A

9

15

16

13

14

FOR CANADIAN INST

ALLA

TIONS

RING

TIP

RING

TIP

( )

( )

(+)

(+)

( )

D

ATA

OUT

SYNC

IN

POWERLINE

CARRIER DEVICES

GND

DA

T A

  IN

DA

T A

 OUT

INCOMING

PHONE

LINE

TO

HANDSET

PHONE

LINE

W

ARNING:

T

O

 PREVENT RISK OF

SHOCK DISCONNECT

TELEPHONE LINE

A

T

 TELECOM 

J

A

CK

BEFORE SER

VICING

THIS UNIT

.

ALL OUTPUT CIRCUITS ARE PO

WER LIMITED

1

2

3

4

8

6

5

11

7

10

12

15

16

13

14

PHONE

FUTURE

USE

SOUNDERS

PLCD

AC

EAR

TH

GR

OUND

RING

TIP

RING

TIP

( )

( )

(+)

(+)

( )

D

ATA

OUT

SYNC

IN

RJ11

8

POS

JA

C

K

9

GND

LOCAL SOUNDER

DISABLE SHUNT

REMO

VE T

O

 DISABLE

UL NO

TE

THE MINIMUM 

WIRE SIZE USED FOR 

TELEPHONE

INST

ALLA

TIONS MUST BE #26 GA

UGE

SUPER HIGH-CAPACITY

BATTERY CONNECTOR

LRR/IP

COMMUNICATIONS

PORT

GSML/GSMVL

COMMUNICATIONS

PORT

STANDARD

HIGH-CAPACITY

BATTERY CONNECTOR

UL INST

ALLA

TIONS

THE MINIMUM 

WIRE

SIZE USED FOR

TELEPHONE

INST

ALLA

TIONS

MUST BE #26 GA

UGE

 

 

Содержание LYNXR-I Series

Страница 1: ...is supplement when installing and programming the new features The new LYNXR I Series features include Compatibility with the AlarmNet GSML GSMVL Communications Devices New 24 hour Carbon Monoxide Monitor Zone Type 14 and compatibility with the 5800CO Carbon Monoxide Sensor Remote Services requires compatible AlarmNet Communications device Wiring Overview The following diagram provides an overview...

Страница 2: ... cable provides DC power and ground for the module and data in data out connections 5 If using the GSMVL connect the provided shielded audio cable between the GSMVL module and the control s PC board COMMUNICATIONS CABLE GSMVL ANTENNA 09012 017 V0 SCREW 3 AUDIO CABLE GSMVL ONLY Installing the GSML GSMVL Communications Module GSML GSMVL Programming If you are installing a GSML GSMVL Communications D...

Страница 3: ...ice Capabilities 4 Follow Me System Follow Me Reminder and Pager features are not supported These features will not work if selected in 49 5 Speaker Phone and Remote Phone Access are not available These features should be disabled in 47 and 91 Download over the Phone Line feature is also unavailable 6 AAV mode can be established only on LRR IP Digital Communication with AAV Capabilities 7 If AAV i...

Страница 4: ... 225 seconds in 15 second increments If 0 is entered the control panel will send redundant reports to both Primary Dialer and the LRR IP communications device 2nd Entry The second entry determines the alternate Central Station communication path that will be initiated after the time out period 78 Programmable Tone Generation Time 00 Disabled 01 09 100 900 ms 10 99 1 0 9 9 secs This field is used t...

Страница 5: ...ad address of 1 must be enabled in the communication device in order for the device to talk to the control panel To Select the User Interface Select LYNX Keypad as the User Interface during account programming on the AlarmNet Direct website Multi mode Feature Multi mode enables users to receive e mail notification of system events Since the communication device is emulating a 4204 or two 4204 modu...

Страница 6: ...e start end defaults for Daylight Savings time have been revised The revised defaults are as follows Function Table 1 Table 2 Table 3 Table 4 29 Daylight saving time start end month 3 11 3 11 3 11 3 11 30 Daylight saving time start end weekend 2 1 2 1 2 1 2 1 55 Reporting Channels 0 0 0 0 78 Programmable Tone Generation Time 0 0 0 0 0 0 0 0 86 Multi mode E mail notification 0 0 0 0 80 DEFAULT TABL...

Страница 7: ... OF CONNECTIONS LYNXR I ALSO COMPLIES WITH THE FOLLOWING CANADIAN STANDARDS ASSOCIATION CSA C22 1 CANADIAN ELECTRICAL CODE PART 1 SAFETY STANDARD FOR ELECTRICAL INSTALLATIONS AND CAN ULC S540 INSTALLATION OF RESIDENTIAL FIRE WARNING SYSTEMS THE LYNXR I CONTROL IS COMPATIBLE WITH THE FOLLOWING INTEGRAL RECHARGEABLE BATTERY PACKS EXTERNAL SOUNDERS AND POWERLINE CARRIER DEVICES HAVE NOT BEEN EVALUATE...

Страница 8: ...2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 Copyright 2008 Honeywell International Inc www honeywell com security ÊK14945TŠ K14945 1 08 Rev A ...

Отзывы: