Honeywell Krom Schroeder VAN Series Скачать руководство пользователя страница 7

VAN · Edition 05.22

EN-7

Switching frequency of closed position indicator: max. 
5 x per minute.

switching 

current

switching cycles*

cos φ = 1

cos φ = 0.6

0.1

500,000

500,000

0.5

300,000

250,000

1

200,000

100,000

3

100,000

* Limited to max. 200,000 cycles for heating systems.

9.4 Air flow rate Q

Air flow rate Q for a pressure loss of Δp = 1 mbar 

(0.4 "WC):

∆p = 1 mbar (0,4 "WC)

Air flow rate

Q [m

3

/h]

Q [sCFH]

VAN 110

4.4

155.4

VAN 115

5.6

197.7

VAN 120

8.3

293.1

VAN 125

10

353.1

VAN 225

15.5

547.3

VAN 232

19.5

688.5

VAN 240

21

741.5

VAN 250

22.5

794.5

10 DesIGneD LIFetIMe

This information on the designed lifetime is based on 

using the product in accordance with these operat-
ing instructions. Once the designed lifetime has been 
reached, safety-relevant products must be replaced.  
Designed lifetime (based on date of manufacture) in 
accordance with EN 13611, EN 161 for VAN: 

type

Designed lifetime

switching 

cycles

time (years)

VAN 110 – 225

500,000

10

VAN 232 – 250

200,000

10

You can find further explanations in the applicable 

rules and regulations and on the afecor website (www.
afecor.org).
 

This procedure applies to heating systems. For ther-

moprocessing equipment, observe local regulations.

11 CeRtIFICAtIon

11.1 Declaration of conformity

We, the manufacturer, hereby declare that the products 
VAN with product ID No. CE-0063BU1564 comply with 
the requirements of the listed Directives and Standards.
Directives:

 

– 2014/35/EU – LVD

 

– 2014/30/EU – EMC

 

– 2011/65/EU – RoHS II

 

– 2015/863/EU – RoHS III

Regulation:

 

– (EU) 2016/426 – GAR

Standards:

 

– EN 161:2011+A3:2013

The relevant product corresponds to the tested type 

sample.

The production is subject to the surveillance proce-

dure pursuant to Regulation (EU) 2016/426 Annex III 

paragraph 3.
Elster GmbH
Scan of the Declaration of conformity (D, GB) – see 
www.docuthek.com
 

AGA approved

AGA

Australian Gas Association

eurasian Customs Union

The product VAN meets the technical specifications 

of the Eurasian Customs Union.

11.2 UKCA certified

Gas Appliances (Product Safety and Metrology etc. 
(Amendment etc.) (EU Exit) Regulations 2019)
BS EN 161:2011+A3:2013

11.3 ReACH Regulation

The device contains substances of very high concern 

which are listed in the Candidate List of the European 
REACH Regulation No. 1907/2006. See Reach list 
HTS at www.docuthek.com. 

11.4 China RoHs

Directive on the restriction of the use of hazardous sub-
stances (RoHS) in China. Scan of the Disclosure Table 
China RoHS2, see certificates at www.docuthek.com. 

Содержание Krom Schroeder VAN Series

Страница 1: ...in accordance with the regulations and standards in force These instructions can also be found at www docuthek com 1 2 Explanation of symbols 1 2 3 a b c Action Instruction 1 3 Liability We will not be held liable for damage resulting from non observance of the instructions and non com pliant use 1 4 Safety instructions Information that is relevant for safety is indicated in the instructions as fo...

Страница 2: ...Elster GmbH Osnabrück Germany XXXX VAN 3 INSTALLATION CAUTION Incorrect installation Please observe the following to ensure that the magnetic relief valve is not damaged during instal lation and operation Sealing material and dirt e g thread cuttings must not be allowed to get into the valve housing A filter must be installed upstream of every system Dropping the device can cause permanent damage ...

Страница 3: ...ed white VAN open CAUTION Please observe the following to ensure smooth operation Route valve and closed position indicator cables separately through M20 cable glands or use two separate plugs Otherwise there is a risk of interference between valve voltage and closed position indicator voltage To make wiring easier the connection terminal for the closed position indicator can be removed 1 3 2 LV1 ...

Страница 4: ... coating No additional grease is required 1 Disconnect the system from the electrical power supply 2 Shut off the gas supply Remove the M20 cable gland or other type of connection 3 4 5 6 7 8 9 Dependingontheconstructionstageoftheunit there are two different methods for replacing the actuator If the unit concerned has no O ring in this place arrow replace the actuator as described here Otherwise g...

Страница 5: ...M5 500 50 VAx 2 M6 800 50 VAx 3 M8 1400 100 10 Then check the unit for internal and external tight ness see page 4 5 Tightness test 8 ACCESSORIES 8 1 Pressure switch for gas DG VC The pressure switch for gas monitors the inlet pres sure pu and the outlet pressure pd Monitoring the inlet pressure pu the pressure switch for gas is mounted on the inlet side Monitoring the outlet pressure pd the press...

Страница 6: ...g with a high pressure cleaner and or cleaning products 9 2 Mechanical data Gas types natural gas LPG gaseous biogas max 0 1 by vol H2S or clean air other types of gas on request The gas must be clean and dry in all temperature conditions and must not contain condensate Medium temperature ambient temperature Max inlet pressure pu 500 mbar 7 25 psig Leakage rate 500 cm3 h 0 132 gal h Closing time q...

Страница 7: ... For ther moprocessing equipment observe local regulations 11 CERTIFICATION 11 1 Declaration of conformity We the manufacturer hereby declare that the products VAN with product ID No CE 0063BU1564 comply with the requirements of the listed Directives and Standards Directives 2014 35 EU LVD 2014 30 EU EMC 2011 65 EU RoHS II 2015 863 EU RoHS III Regulation EU 2016 426 GAR Standards EN 161 2011 A3 20...

Страница 8: ...ve At the end of the product life number of op erating cycles reached dispose of the pack aging and product in a corresponding recycling centre Do not dispose of the unit with the usu al domestic refuse Do not burn the product On request old units may be returned carriage paid to the manufacturer in accordance with the relevant waste legislation requirements 2022 Elster GmbH We reserve the right t...

Отзывы: