CHAPTER
3
IH21 Bluetooth UHF RFID Reader
17
MAINTENANCE AND
TROUBLESHOOTING
Maintenance
For trouble-free service please observe the following tip when using the IH21
Reader:
•
Protect the IH21 Reader from temperature extremes. Do not leave it on the
dashboard of a car on a hot day and keep it away from heat sources.
Troubleshooting
Symptoms
Possible Cause
Action
Nothing happens when the
button is pressed.
If the LEDs are not on, then the
battery may need to be
charged.
Charge the reader.
The reader may have button
actions disabled.
Check the reader configuration
and restore to defaults.
The orange LED flashes rapidly
when charging.
There is a battery fault.
Replace the battery pack.
The battery pack temperature
is outside recommended limits.
Ensure charging only occurs
between 41°F and 104°F (5°C
and 40°C.)
The host
Bluetooth®
discovery
does not find the reader.
The reader has powered off.
Press the button and ensure
the blue LED is flashing.
The reader is out of range.
Move the reader closer to the
host.
The
Bluetooth®
friendly name
of the reader has been
changed.
Check the
Bluetooth
friendly
name or restore the reader to
factory defaults.
Opening the
Bluetooth
virtual
com port does not connect to
the reader.
The host has paired to a
different
Bluetooth
device.
Pair to the required reader.
The host
Bluetooth
function
has an error.
Warm boot the host. If this
does not help, delete the reader
from the favorites list and re-
pair.