Starting Generator
14
www.honeywellgenerators.com
HW5600C Portable Electrical Generator Owner’s Manual
Starting Generator
1.
Place generator outside in a well-ventilated area.
2.
Confirm the circuit breakers are set.
3.
Test GFCI per instructions on page 25.
4.
Turn fuel shut-off valve to ON position.
5.
Pull choke control to ON position.
6.
Press engine control switch to RUN position.
7.
Grip recoil starter handle and pull slowly until you feel
slight resistance.
8.
Apply swift pulls to start the engine, carefully returning
the recoil starter handle to the original position. This
may need to be repeated 2-3 times until the engine
starts.
9.
As engine warms up, and RPM stabilizes, gradually
push choke control to OFF position.
10.
Confirm the GFCI outlets are set (illuminated red).
Thoroughly read and understand all information
provided in this Owner’s Manual before operating
generator.
NOTICE
It is very important to maintain proper level of engine oil to
keep engine in good running condition.
• Check engine oil level prior to each use.
Starting generator with appliances connected can cause
permanent damage to appliances.
• NEVER start generator with electrical appliances
plugged in and turned on.
NOTICE
Keep the generator at a minimum of 6 feet (2 meters) from
any building, object, or wall.
FIGURE 16:
Circuit Breaker Position
FIGURE 17:
Fuel Shut-off Valve — ON/OFF Position
FIGURE 18:
Choke Control
WARNING
Set
Tripped
Set
Tripped
ON
OFF
FIGURE 19:
Engine Control Switch
FIGURE 20:
Recoil Starter Handle
NOTICE
Do not allow the recoil starter handle to snap back against
the engine. Return it gently to prevent damage to the starter.
NOTICE
If engine will not start, move the choke to the OFF posi-
tion to reduce fuel to the engine.
FIGURE 21:
GFCI Setting
RUN
ENGINE
STOP
TEST
RESET
Set