Honeywell
26
Figure 4-12 Schedule Menu
Quick Setup
This function allows you to copy one channel setup to another. After setting one
channel, you can click Copy button and switch to another channel and then click
Paste button. You can finish setting one channel and then click Save button to
keep the setting of that channel, or you can finish all setup and then click Save
button to keep all the modified settings.
Detect
Go to Detect Menu
In the main menu, from Setting to Detect, you can see motion detect interface. See
Figure 4-13
. There are three detection types: motion detection, video loss, camera
masking.
Motion Detection
Detection menu is shown as below. See
Figure 4-13
.
•
Event type: From the drop-down list you can select the “Motion Detection” type.
•
Channel: Select the video channel for motion detection setting.
•
Record Channel: Select the channel to activate recording function once alarm
occurred. Please make sure you have set MD recording in schedule
interface(
Main Menu
Æ
Setting
Æ
Schedule
) and automatic recording in
manual record interface(Main Menu->Advanced->Manual Record)
•
Delay: when detected motion is completed, system continues alarm output and
recording for a specified time respectively. The value ranges from 10-300(Unit:
second).
•
Region:
Click
Select
, the interface is shown as in
Figure 4-14
. Here you can
set motion detection zone. There are 396(PAL)/330(NTSC) small zones.
•
Sensitivity: System supports 6 levels. The sixth level has the highest sensitivity.
The fifth or lower levels are recommended to avoid false alarm.
Содержание HSVR-16
Страница 2: ......
Страница 6: ...Honeywell iv 8 Appendix 111 HDD Capacity Calculation 111 Compatible USB Drive List 112 ...