background image

G    N    L

HP1210UL- 16

Power Module 1: Output 

Terminal Block for circuits 1-4

Power Module 2: Output 

Terminal Block for circuits 1-

Power Module 1:

Block for circuits 5-8 and Voltage 

Power Module 2: Output 

Terminal Block for circuits 

AC power input

A MINIMUM OF ¼” SHALL BE 

MAINTAINED BETWEEN THE 

FIELD WIRING AND THE 

INTERNAL FACTORY WIRING

+

-

+

-

BAT +

BAT -

BAT +

BAT -

FACTORY INSTALLED AC WIRING

CLASS 2 POWER LIMITED OUTPUTS

CLASS 2 POWER LIMITED 

OUTPUTS

+ -

VO4

+ -

VO3

+ -

VO2 VO1

+ -

LED 4 LED 3 LED 2 LED1

+ -

VO4

+ -

VO3

+ -

VO2 VO1

+ -

G    N    L

1205-4CB-PCB

POWER MODULE 1

1205-4CB-PCB

G    N    L

POWER MODULE 2

EARTH GROUND

VOLTAGE 

ADJUSTMENT

+ -

VO8

+ -

VO7

+ -

VO6 VO5

+ -

LED 8 LED 7 LED 6 LED 5

+ -

VO8

+ -

VO7

+ -

VO6 VO5

+ -

LED 8 LED 7 LED 6 LED 5

VOLTAGE 

ADJUSTMENT

BATTERY

+

-

BATTERY

+

-

+  1  - +  2  - +  3  - +  4  -

+ -

VO8

+ -

VO7

+ -

VO6

VO5

+ -

LED 8 LED 7 LED 6 LED 5

+  1  - +  2  - +  3  - +  4  -

+ -

VO4

+ -

VO3

+ -

VO2

VO1

+ -

LED 4 LED 3 LED 2 LED 1

Fig. 1

+  1  - +  2  - +  3  - +  4  -

+ -

VO8

+ -

VO7

+ -

VO6

VO5

+ -

LED 8 LED 7 LED 6 LED 5

+  1  - +  2  - +  3  - +  4  -

+ -

VO4

+ -

VO3

+ -

VO2

VO1

+ -

LED 4 LED 3 LED 2 LED 1

Fig. 1

Keep .25” spacing between power-limited wiring and non power-limited wiring

LED 4 LED 3 LED 2 LED1

Содержание HP1205UL-4

Страница 1: ...aximum temperature range 20 C to 40 C For indoor use only Relative humidity 20 90 85 of Efficiency with full load Maximum ripple 150mVp p Maximum noise 200mVp p Built in charger on select power supplies for sealed lead acid battery Individual outputs current limited at 2 5 Amps per circuit Maximum battery charge 500mA Subtract from total output Red LED s indicate DC power presence on each circuit ...

Страница 2: ...ge wiring 7 Keep a 1 4 0 635 cm separation between power limited wiring and on power limited wiring Use separate knockouts for power limited wiring 8 Connect CCTV cameras or other external loads to appropriate terminals shown in Fig 1 Connect circuit 1 to terminals marked VO1 and VO1 Connect circuit 2 to terminals marked VO2 and VO2 Continue to connect the remaining circuits carefully observing po...

Страница 3: ...is present Check battery to make sure it is not worn out or defective WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE RISK OF ELECTRICAL SHOCK AND OR EQUIPMENT DAMAGE DISCONNECT POWER BEORE SERVICING THIS APPLIANCE MAINTAIN A 1 4 OF SEPARATION BETWEEN THE AC MAINS AND ALL LOW VOLTAGE WIRING A READILY ACCESSIBLE SWITCHED CIRCUIT BREAKER MUST BE ...

Страница 4: ...VO1 LED 4 LED 3 LED 2 LED 1 EARTH GROUND 1 2 3 4 VO4 VO3 VO2 VO1 LED 4 LED 3 LED 2 LED 1 Fig 1 LED 5 LED 6 LED 7 LED 8 BAT BAT 1205 4CB PCB 5 6 7 8 1 2 3 4 G N L LED 1 LED 2 LED 3 LED 4 BATTERY VOLTAGE ADJUSTMENT CLASS 2 POWER LIMITED OUTPUTS VO8 VO7 VO6 VO5 LED 8 LED 7 LED 6 LED 5 VO4 VO3 VO2 VO1 LED 4 LED 3 LED 2 LED 1 A MINIMUM OF 1 4 SHALL BE MAINTAINED BETWEEN THE FIELD WIRING AND THE INTERNA...

Страница 5: ...ING BAT BAT BAT BAT FACTORY INSTALLED AC WIRING CLASS 2 POWER LIMITED OUTPUTS CLASS 2 POWER LIMITED OUTPUTS VO4 VO3 VO2 VO1 LED 4 LED 3 LED 2 VO4 VO3 VO2 VO1 G N L 1205 4CB PCB POWER MODULE 1 1205 4CB PCB G N L POWER MODULE 2 EARTH GROUND BATTERY BATTERY 1 2 3 4 VO4 VO3 VO2 VO1 LED 4 LED 3 LED 2 LED 1 Fig 1 1 2 3 4 VO8 VO7 VO6 VO5 LED 8 LED 7 LED 6 LED 5 Fig 1 Keep 25 spacing between power limited...

Страница 6: ...S CLASS 2 POWER LIMITED OUTPUTS VO4 VO3 VO2 VO1 LED 4 LED 3 LED 2 LED1 VO4 VO3 VO2 VO1 G N L 1205 4CB PCB POWER MODULE 1 1205 4CB PCB G N L POWER MODULE 2 EARTH GROUND VOLTAGE ADJUSTMENT VO8 VO7 VO6 VO5 LED 8 LED 7 LED 6 LED 5 VO8 VO7 VO6 VO5 LED 8 LED 7 LED 6 LED 5 VOLTAGE ADJUSTMENT BATTERY BATTERY 1 2 3 4 VO8 VO7 VO6 VO5 LED 8 LED 7 LED 6 LED 5 1 2 3 4 VO4 VO3 VO2 VO1 LED 4 LED 3 LED 2 LED 1 Fi...

Отзывы: