SM 2/2500 (see drawing 6b)
The following parts have to be replaced in this component.
O-ring
16
O-ring
18
To replace these parts, the following steps are to be taken.
Disconnect impulse line 21
Unscrew screw connections 15
Remove cover 01
Remove cylinder 03 to replace O-ring 16
Remove plunger 05 to replace O-ring 18
Replace O-ring 18
Replace O-ring 16
Fit plunger 05, cylinder 03 and cover 01
Tighten screw connection 15 (even and diagonally)
Connect impulse line.
Figure 6b: Pressure converter SM2/2500