Data (Video & Audio Clip) Back-up 

 

Data Copy (Max. 1hour’s video clip) 

 

 

External HDD or External CD-R on IEEE1394 

(FireWire) port 

External USB Memory Disk(USB 1.1 compatible) on 

USB port 

Backup Notification: Daily / Weekly / Monthly 

Monitor A Displaying Performance 
 

Frame Rate on CCTV Monitor: Max. 480Fps 

Quad Mode : 1/4/9/16/13 Channels 

Sequence Switching : Auto, User Defined

 

Monitor A Playback Performance 

Frame Rate : total 60ips 

Quad Mode : 1/4/9/16 channels 

Play speed: 1x, 2x, 4x, 8x, 16x (FDW & REV) 

Supports Step-Forward, Step-Reverse. 

Instant data access based on time and event log 

Monitor A Output 

1 CVBS   

1 Y/C 

Monitor B Displaying Performance 
 

Frame Rate on CCTV Monitor: Max. 30Fps 

Single Channel mode only 

Sequence Switching : Auto, User Defined

 

Monitor B Playback Performance 

Frame Rate : total 60ips 

Single Channel mode only 

Play speed: 1x, 2x, 4x, 8x, 16x (FDW & REV) 

Supports Step-Forward, Step-Reverse. 

Instant data access based on time and event log 

Monitor B Output 

1 CVBS   

Digital Zoom 

2 times digital zoom (Live & Playback Mode)

 

Event Triggered Pop-up Video 

Triggered by motion detection or sensor input 

PTZ Control 

Ports: RS232(2) , RS485/RS422(2) 

Local User   

Front panel push button & IR Remote 

(controls IP video channels as well) 

Remote User   

On-the-screen PTZ control on PC 

Preset: 8 points per channel 

Group: 1 group per channel 

Return Home Position’ support 

Sensor Inputs and Alarm Outputs 

Software-controlled 16 sensor inputs 

Software-controlled 4 alarms outputs 

Software-controlled 1 internal buzzer 

Содержание HNDR-S4824

Страница 1: ...HNDR S4824 User s Manual v 2 0 ...

Страница 2: ...accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may ...

Страница 3: ...DR S Series DVR Physical shocks may harm the product In addition be sure the HNDR S Series DVR is secured after installation 5 HNDR S Series DVR is made of metal Therefore you can hurt human beings if you throw it to them or hit on them When installing HNDR S Series DVR be cautious to locate on safe places where children are unreachable 6 If HNDR S Series DVR does not operate properly please conta...

Страница 4: ...4 1 Basic sequence mode 13 3 4 2 User sequence mode 14 3 5 Viewing an alarm triggered channel 15 3 6 Viewing images with Digital Zoom 15 3 7 Viewing with connected PTZ 15 3 7 1 Controlling Pan Tilt 16 3 7 2 Controlling Zoom Focus 16 3 7 3 Using Load Preset 16 3 7 4 Using Save Preset 16 3 7 5 Using Clear Preset 16 3 7 6 Using Auxiliary On 17 3 7 7 Using Auxiliary Off 17 3 8 Using Relay 17 3 9 Using...

Страница 5: ...ata 26 5 Configuration 27 5 1 Quick Setup 27 5 1 1 Date Time 27 5 1 2 Recording 30 5 2 Camera 32 5 3 Normal Rec 35 5 3 1 Setting Global 35 5 3 2 Setting by channel 36 5 4 Alarm Rec 39 5 4 1 Setting sensor 39 5 4 2 Setting Motion Detection 40 5 4 3 Text 42 5 4 4 Setting global alarm recording 44 5 4 5 Setting by channel 45 5 5 Alarm Act 46 5 5 1 Schedule 46 5 5 2 Setup 47 5 6 Monitor 48 5 7 System ...

Страница 6: ...6 6 1 2 Setting at Serial Setup s RS232 menu 67 6 1 3 Setting at Alarm Rec menu 68 6 1 4 Setting at Normal Rec menu 69 6 2 Using Keyboard 70 6 2 1 Setting at Serial Setup s COM1 menu 70 6 2 2 Setting at Serial Setup s PTZ menu 70 APPENDIX 71 1 Technical Specification 72 2 Utilizing IP Addresses on Local Network 75 2 1 Introduction 75 2 2 IP construction and Network class 75 2 3 C class Network 76 ...

Страница 7: ...G images HNDR S4824 also allows users to record and playback audio for one channel Setting up HNDR S4824 is as easy as setting up a VCR HNDR S4824 starts to record as soon as power is supplied and CCTV cameras are connected HNDR S4824 offers an easy setup as well as advanced menus With Quick Setup HNDR S4824 can be setup and begin recording in 5 minutes The default settings offer qualified and eff...

Страница 8: ...ing event recording data ATM POS transaction text information recording and search with corresponding video 16 sensor inputs and 4 alarm outputs Built in hardware motion detection 64 division comparison Back up with IEEE 1394 FiWi PTZ Control Preset support via RS 232 or RS 485 RS422 User friendly 32bit True color Graphic OSD Menu Dynamic IP DHCP Floating IP support Optimized Wavelet compression 1...

Страница 9: ...linking indicates the speed of playback i e When blinking rapidly HNDR S4824 is playing back at a high rate when blinking slower the HNDR S4824 is playing back at a lower rate Its status is same when using HNDR S Series Manager A B Displays monitor status When selecting monitor A LED is off When selecting monitor B LED is on 2 Remote Controller Receiver 3 Power Switch When pressing the power switc...

Страница 10: ...ELAY To toggle the Relay On Off function in Monitoring mode or to go back to previous status at alarm pop up mode MONITOR To select monitor A or B for controlling 6 Channel Selection Button To select video input channel in monitoring and playback mode LED above channel shows each status of channel GREEN Shows monitoring mode ORANGE Shows alarm MD Sensor No Vdieo triggered status RED Shows relay R1...

Страница 11: ...utput 6 Serial Port DIO Sensor In 16 sensor inputs Relay Out 4 relay outputs COM1 RS232 9Pin D Sub connector COM2 RS422 485 terminal block COM3 COM4 RS232 RS422 485 RJ45 connector IEEE1394 2 3 Installation Summary Connect Camera Connect Monitor Connect Ethernet This is optional to view image on remote location Connect Audio Connect Power Run 3 Power Connector 4 Video Input Loopback 1 Audio In Outp...

Страница 12: ...ollowing functions are described on the base of Monitor A For controlling Monitor A Monitor A should be selected with the front panel menu 3 1 Viewing basic screen 16 ch split Insert AC cord s plug in a wall outlet and HNDR S4824 starts running automatically LED is on and HNDR S4824 starts booting After start up the basic screen 16ch split is displayed If user password is set a dialogue box for en...

Страница 13: ...lt value is 3 seconds per channel for display Select Monitor A menu of Monitor tab among Configuration menus And press the ENTER button Select Seq Switching sec and set any value between 1 and 60 seconds In order to move to sequence mode from any viewer mode press the SEQ button In order to exit from sequence mode press the SEQ button once again Note Sequence mode can run only when connected and a...

Страница 14: ...is set in User Sequence Configration of Monitor A Note 1 User sequence mode can be configured up to 16 sets 2 The example above is when 6 sets In this case HNDR S4824 shows in order quad spilit screen 1 2 3 4 Æ full single screen 1 Æ quad spilit screen 5 6 7 8 Æ full single screen 5 Æ full single screen 8 Æ 9 spilit screens 9 10 11 12 13 14 15 16 ...

Страница 15: ...the Digital Zoom feature To enable the digital zoom press the ZOOM button Digital Zoom will expand the image to twice its normal size Default location of the digital zoom is in the center of screen The zoom box can be moved each 10th step to left and right and 7th step up and down To move the zoom box use the Arrow button To cancel the zoom box press the ZOOM button once more 3 7 Viewing with conn...

Страница 16: ...t panel 3 7 3 Using Load Preset To load preset for dome camera during live monitoring mode Press the SELECT button Move the Select icon to the desired channel Press the MENU button Select Load Preset from the PTZ Menu Press number button for desired preset on the front panel 3 7 4 Using Save Preset To set a new preset point for dome camera during live monitoring mode Move dome camera to the desire...

Страница 17: ...Off To stop a special function of PTZ device at live monitoring mode 3 8 Using Relay To set relay on off HNDR S4824 supports four relay outputs Press the ACK RELAY button The icon of Relay On shows on the screen Press the relay number button between 1 and 4 and then the related relay out signal will be transmitted In order to set relay off press the ACK RELAY button again Then Relay On shows becau...

Страница 18: ... this function user password should be set at first If pressing the EXIT LOCK button for 2 3 seconds lock mode will run with showing Screen Locked message on the screen When User Password is set as off the message of Enable user password first shows on the screen If lock mode runs any function button will not be operated In order to cancel lock mode user password should be entered ...

Страница 19: ...plit screen mode User sequence When monitoring 12 channels by 13 split screen mode in Monitor A administrator monitors four channels by user sequence mode in Monitor B simultaneously Quad split sequence mode 1ch monitoring When monitoring all channels by each quad split sequence mode administrator monitors the important channel in Monitor B simultaneously 3 10 2 Multi channels playback Administrat...

Страница 20: ...Configuration 20 2004 05 31 v 2 0 Honeywell 3 10 3 1 ch playback Administrator can monitor multi cahnnels by split screen mode in Monitor A and search playback 1 channel by single full screen in Monitor B simultaneously ...

Страница 21: ...24 4 1 2 Playback via a split screen 4 9 16 Press the MULTI button during basic single channel playback mode Channels 1 to 4 will be displayed in the quad split screen To display a single channel press the corresponding number button on the front of the HNDR S4824 4 1 3 Playback Ch 5 16 via 4 9 split screen Possible to play with pressing the SEQ button or selecting a channel Press the SELECT butto...

Страница 22: ...x1 x2 x4 x8 x16 REW Each press of the button will increase playback speed gradually x1 x2 x4 x8 x16 STEP FORWARD Pressing PLAY or FFW button from PAUSE status will replay image frame by frame In order to go back to normal playback mode press STOP button then press PLAY or FFW button STEP REWIND Pressing FRW button from PAUSE status will replay image frame by frame In order to go back to normal pla...

Страница 23: ...HNDR S4824 search the related time Button control Press the SEARCH button in playback mode Search for data by entering Date Time or by selecting an event from the Event Log browser Press the ENTER button after entering the desired Date Time or selecting Event from log The selected images will begin to playback To exit from search mode press the EXIT button Note Using Log Browser 1 To move to the p...

Страница 24: ...py backup delete the recorded data This menu is activated during playback mode Press the SELECT button and MENU button in Playback mode 4 3 1 Copy Image To copy a specific data with USB memory stick Seconds To designate copy range between 1 second and 60 minutes Select Disk Select copy disk ...

Страница 25: ...backup device To change the disk status use the Disk Manager menu under the System tab Note Backup Manager does not support USB devices Backup Manager will ONLY work with devices connected through IEEE1394 FireWire ports CD R is supported and CD R media should be used as 700MB or above When using HDD backup the file format will be re3 When using CD R backup the file format will be vfs2 ...

Страница 26: ...from the current recording HDD This menu does not affect backup disk The beginning of the range is always the beginning of the recording on the HDD Note The block unit of HNDR S Series s file system is 64MB and HNDR S Series DVR delets by block So data may not be deleted correctly even though time is designated ...

Страница 27: ... menu 5 1 1 Date Time When HNDR S4824 is manufactured in factory time zone will be set as UTC 00 00 Dublin Set the time to local time zone Changing HNDR S4824 time may cause time conflict with recorded images In this case it is strongly recommended to re format the hard drives after making changes Button control Press MENU button on HNDR S4824 front panel Move to Quick Setup menu First tab on the ...

Страница 28: ...nly activated for time zones that use Daylight Savings For example selecting GMT 7 00 Arizona will disable the option for Daylight Savings because Daylight Savings is not used in Arizona This menu is linked with Time Zone menu Namely if selecting daylight saving area in time zone this menu will be activated Oppositely if selected time zone is not enforced it will not be It is based on MS Windows S...

Страница 29: ...right arrow buttons To select each month each day etc use the up down arrow buttons Apply Date Time Press this button to confirm the above settings An window will pop up warning of the possibility of time conflict with recorded images It is strongly recommended to format the HDD after making changes to the time menu Note Most setting values are applied automatically when exiting from the related m...

Страница 30: ...from the Quick Setup tab Configuration Status Displays the recording setup status If recording is configured with the Quick Setup Macro Setup will be displayed If recording is configured with the Normal and Alarm recording Custom Setup will be displayed Note When all 16 analog cameras normal recording conditions are set identically the status is marked as Macro Setup Otherwise it is marked as Cust...

Страница 31: ...tically Low setting is 1ips Q3 Standard setting is 5ips Q3 High setting is 15ips Q3 When using the Custom setting Speed ips and Quality can be set separately Audio Recording Enables the audio recording feature If audio is set as On and Audio Synch with is set as All in the Audio menu under the System tab audio will be available in Playback Mode with all channels Apply Confirms the Quick Setup Reco...

Страница 32: ...utomatically set as On Settings such as Brightness and Contrast can be set for each channel The values assigned will apply for both monitoring and playback modes Button control Press MENU button and use the ARROW keys to move to each channel below the Camera tab Name Assign a customized name to the channel Press ENTER to open the necessary dialogue box ...

Страница 33: ...n HNDR S4824 front panel 0 to 9 When using the ARROW buttons use the PLAY button to select each choice The intersection between the horizontal and the vertical bar is the selected choice Press the button to confirm the selected value Or enter the related numbers in order of horizontal vertical For example in order to select C press 3 and 2 button After setting all values press the Exit button Func...

Страница 34: ...AGC Auto Gain Control Set Enable Disable using the or buttons after pressing the ENTER button Brightness Contrast Set the value between 9 and 9 using the or buttons after pressing the ENTER button Covert If setting Covert as On channel will be hidden in monitoring mode Set A B Both Off using the or buttons after pressing the ENTER button PTZ Home PTZ Idle Time If there is not any movement during P...

Страница 35: ...y the Normal Recording settings 5 3 1 Setting Global It is similar to Quick Setup s recording setting It is for setting all channels by same conditions Note 1 Differently from Quick Setup s recording condition global setting doesn t have Audio Recording menu and have Special Time Recrding and Event Recording menus 2 To confirm the configured values you should press the Apply button 3 For more info...

Страница 36: ...6 2004 05 31 v 2 0 Honeywell 5 3 2 Setting by channel Time Schedule Each camera can be set to record based on four time schedules Weekday Day Weekday Night Weekend Day Weekend Night Each schedule can be configured under the System tab ...

Страница 37: ... is set automatically based on Weekday range Day Start End Set the range for Day using the up down buttons The Night range is set automatically based on Day range Recording Speed Quality There are five conditions No Rec Low Standard High Custom All conditions except Custom synchronize Speed ips and Quality automatically Low setting is 1ips Q3 Standard setting is 5ips Q3 High setting is 15ips Q3 Wh...

Страница 38: ... Standard High Same as above Setting Special Time To set Special Time move to System tab Up to four zones can be designated as Special Time Event Recording Press the ENTER button to access the Event Recording feature Set On Off using the or buttons Event recording condition is set under the Alarm Recording tab This setting is used to configure the HNDR S4824 to record data according to an alarm co...

Страница 39: ...set Event Recording under the Normal Recording tab to On And Alarm Source should be set before alarm recording menu 5 4 1 Setting sensor It is for setting sensor type HNDR S Series supports Normal Open N O and Normal Close N C types Global To set all sensors by same conditions Select one among Off N O N C and press the Apply button Configuration To set each sensor seperately ...

Страница 40: ... possible to set each channel separately Motion Detection Choose from among four sensitivity conditions Off Low Standard and High MD Area Customize the MD area among 64 sectors 8 sectors x 8 sectors Default value is Select All Select Custom Area to move to setting page Include Video Loss Set whether no video situation is set as MD or not Note After setting it as Global press the Apply button certa...

Страница 41: ...tection triggered event Press the Custom Area button to customize the motion detection area The area is divided into 64 blocks 8 x 8 Selected MD area is indicated in dark gray To remove blocks from motion detection select the block using the ARROW buttons and press the ENTER button Press the EXIT button when finished ...

Страница 42: ...nize with text Seek Header If a protocol is built in HNDR S4824 like Star Finger 007 this setting is needless Otherwise HNDR S4824 can t recognize which parameter value is input to HNDR S4824 Namely all information has starting point and ending point Header means starting point that is always inserted So when this header data is transmitted to HNDR S4824 HNDR S4824 can recognize it as starting poi...

Страница 43: ...t can be included within a data However length of each data may be different Because HNDR S4824 can t recognize it automatically timeout menu is needed Namely if specific time passes after HNDR S4824 receives the last line HNDR S4824 will regard it as normal data and decide to record Lines To set maximal line of a data ...

Страница 44: ...hannesl by same condition Sensor MD Set the co work of sensor MD Pairing means channel runs sensor MD by 1 to 1 Text In order to display or record text with image it should be set as On Note 1 After setting it as Global press the Apply button certainly 2 For more information please refer to the following Setting by channel ...

Страница 45: ... input Note 1 Press the ENTER button 2 or Press the 0 button Recording Speed Quality There are four conditions Low Standard High Custom All conditions except Custom synchronize Speed ips and Quality automatically Low setting is 1ips Q3 Standard setting is 5ips Q3 High setting is 15ips Q3 When using the Custom setting Speed ips and Quality can be set separately Pre Alarm sec Set a value up to 10 se...

Страница 46: ...onfigured 5 5 1 Schedule Select Action Source In the menus of Relay1 Relay4 Buzzer and E mail Sensor or MD can be set upto 4EA or ANY And Text can be set as On Off For selecting sensor MD press the channel number to set Note 1 ANY Press the ENTER button Special Time Enable Special Time in order to apply the relay schedule to the Special Time Zone Note 1 Global means to set all time schedules by sa...

Страница 47: ...rm MD or sensor is triggered E mail Enters E mail address to receive alarm information SMTP Enters DNS of mail relay server Sending Interval min HNDR S4824 doesn t send E mail whenever alarm is triggered It sends at the set interval Interval can ne set between 1 and 30 minutes Note For using E mail function DNS should be set in Network configuration ...

Страница 48: ...et sequence time between 1 and 60 seconds Note If channel 1 pops up and channel 2 also pops up during pop up hold time screen is changed to quad split screen and channel 1 and 2 are shown And the pop up hold time is extended automatically Up to 8 channels User Sequence Configuration To set user sequence mode Note 1 User sequence mode can be set upto 16 2 The example above shows 6 sequence sets Qua...

Страница 49: ...ed channel or with all of them Recording Set to On using the ENTER button and the ARROW buttons to record audio Audio Gain Increases or decreases the sensitivity to the audio signal Can be set between 7 and 8 20dB To amplify the audio input signal Should ONLY be used when using an external microphone Sync Audio with Designate which channel s to synchronize audio with during playback ...

Страница 50: ...and Day Night Weekday Start End Press ENTER to access the Time Setting Set the range for Weekday between Monday and Sunday using the or button Weekend is set automatically based on Weekday range Day Start End Set the range for Day using the up down buttons The Night range is set automatically based on Day range ...

Страница 51: ...Basic Configuration HNDR S4824 Honeywell 2004 05 31 v 2 0 51 5 7 3 Special Time Up to four zones can be designated as Special Time ...

Страница 52: ...fault password is 0000 Admin Password Designate an Administrator s Password to control access to Configuration Menu and full system control authority Default password is 9999 Remote Setup When set to Enable users can configure HNDR S4824 through the S W interface from a remote site via network Remote Relay Enables access to the Relay menu from a remote site ...

Страница 53: ...o Deletion When there is no room to record in HDD the recorded data is deleted automatically Backup Reminder A Backup Reminder can be set to remind users to backup the HDD The reminder can be set to appear daily weekly or monthly Day Date Time To set the time for the Backup Reminder ...

Страница 54: ...Ethernet If HNDR S4824 is connected on xDSL line that needs PPPoE process to connect to the Internet administrator should select xDSL However if the xDSL line does not need PPPoE process administrator should select Ethernet even though HNDR S4824 is connected on xDSL line DHCP Basically this menu is for the lines that have Ethernet interfaces such as Internet dedicated line cable modem line and LA...

Страница 55: ...over the Internet IP Address NetMask and Gateway Address DNS Administrator may configure IP address subnet mask gateway address and DNS addresses of HNDR S4824 5 7 6 2 xDSL If HNDR S4824 is connected on xDSL line and needs PPPoE process the network administrator should configure the user ID and password for PPPoE ID The password may be acquired from the ISP that installed the line Once configured ...

Страница 56: ... users to find the changed IP address when they want to access the HNDR S4824 To register dynamic IP address to WRS configure the descriptions below If using xDSL modem or Cable modem configuration should be the same WRS Interval WRS Interval should be set by second This designates the frequency the HNDR S4824 will update information to the WRS It is recommended to set as 3600 seconds If the WRS r...

Страница 57: ... WRS from the HNDR S4824 belonging to group The group ID should be unique to avoid unauthorized access to the HNDR S4824 Unauthorized users will not be able to access the HNDR S4824 unless they have a login name and password but they will be able to see the unit on their registration list Status Displays the registration status of the HNDR S4824 ...

Страница 58: ...umber to an open port some firewalls and or ISPs block certain ports press the ENTER button and use the dialogue box TP Server Port The port used for Transparent Protocol server Firewall Port If there is a firewall on the network and a unique port is available user may configure the Monitor and Playback ports as one port In order to change a port select Port menu and configure a suitable port valu...

Страница 59: ...DR S4824 s NTP mode between Client and Server NTP Server Loc It is possible to set after setting NTP Mode as Client Set whether NTP server is on Local Network or Internet Public NTP Local Server IP It is possible to set after setting NTP Server Loc as Local Set the server s IP address Set NTP server s IP address on local Network or the IP address of HNDR S4824 that is set as server in NTP mode Int...

Страница 60: ... has total 4 COM ports Device Designate the connected external device Interface Used to designate the protocol on the RS422 RS485 Menu COM1 and COM3 are fixed as RS232 Baud rate Parity Stop bit Data bit Each value should be set according to the specifications of the connected external device ...

Страница 61: ...nique number under the Remote Control ID menu When not using remote controller set it as Off How to set remote controller Aim remote controller at the HNDR S4824 Press the ID button of remote controller until HNDR S4824 reacts If remote controller s ID agrees with HNDR S4824 s all the LEDs on the front panel of the HNDR S4824 will light up and a buzzer will sound OSD menus can now be set with the ...

Страница 62: ...cameras are designated automatically For example 1st HNDR S4824 has five cameras and 2nd HNDR S4824 has six cameras keyboard PTA address of 1st HNDR S4824 should be set as 1 and one of 2nd HNDR S4824 be set as 6 Be cautious that PTZ addressed are assigned to all cameras automatically in spite of non PTZ camera DVR ID For use with the HNDR S Series Manager to control and manage several HNDR S4824s ...

Страница 63: ...Honeywell 2004 05 31 v 2 0 63 5 8 Utility The following description is how to add format internal or external HDD HNDR S4824 supports various external storages Button control Press MENU button and move to Utility below the System tab ...

Страница 64: ... selecting this menu Alarm Partition menu is activated Alarm Partition means to make one HDD with Normal Recording and Alarm Recording parts Remove Remove current HDD HDD can be reused without data loss by the Add Used command Confirm Removed Used when a removed HDD is still listed ALL DATA WILL BE LOST Add used Add a HDD that has been used and formatted There is no need to reformat It is possble ...

Страница 65: ... it will be changed to R There is no need to format again F Connected but not available file system FAT FAT32 file system After using Add make HDD available for recording R Connected and undergone the Add command HDD needs to be formatted to be available for recording R X HDD cable is not connected or HDD has a problem It is recommended to delete from list using Confirm Removed C It means external...

Страница 66: ...vice In order to use text device the following four menus should be set Text menu Serial Setup s RS232 menu Alarm Rec menu Normal Rec menu 6 1 1 Setting at Text menu Set both Recording and Monitoring as On Set Sync Text with value If the connected device is Star Finger 007 select it at Device menu If not set Manual and each sub menu ...

Страница 67: ...Advanced Configuration HNDR S4824 Honeywell 2004 05 31 v 2 0 67 6 1 2 Setting at Serial Setup s RS232 menu Set RS232 s device menu as Text And set baud rate parity stop and data ...

Страница 68: ...HNDR S4824 Advanced Configuration 68 2004 05 31 v 2 0 Honeywell 6 1 3 Setting at Alarm Rec menu Set text event as On ...

Страница 69: ...layed image is different The default value of Monitoring mode is to show just channel number Then next step is to show channel name and text event status and HDD status The default value of Playback mode is to show all information The next level is to show channel name and text event status and channel number So in order to view text data press the Help button once at both Monitoring and Playback ...

Страница 70: ...be set Serial Setup s RS232 menu Serial Setup s PTZ menu 6 2 1 Setting at Serial Setup s COM1 menu Set RS232 COM1 s device menu as Keyboard And set baud rate parity stop and data 6 2 2 Setting at Serial Setup s PTZ menu Set PTZ camera to control with keyboard For more detailed technical solution please contact the closest local distributor ...

Страница 71: ...APPENDIX HNDR S4824 Honeywell 2004 05 31 v 2 0 71 APPENDIX APPENDIX ...

Страница 72: ...tor Recording Performance on 360X243 Analog Ch Max 240ips NTSC 200ips PAL in total Max 30ips NTSC per channel if 8ch used Max 15ips NTSC per channel if 16ch used Schedule Recording Daily Day night Four segment time frame Weekly Weekdays Weekends Status Normal Event Matrix Digital Output Schedule Daily Day night Four segment time frame Weekly Weekdays Weekends Conditions MD sensor input Configurabl...

Страница 73: ...ing Performance Frame Rate on CCTV Monitor Max 30Fps Single Channel mode only Sequence Switching Auto User Defined Monitor B Playback Performance Frame Rate total 60ips Single Channel mode only Play speed 1x 2x 4x 8x 16x FDW REV Supports Step Forward Step Reverse Instant data access based on time and event log Monitor B Output 1 CVBS Digital Zoom 2 times digital zoom Live Playback Mode Event Trigg...

Страница 74: ...io monitoring Network Protocol TCP IP ARP ICMP DHCP PPPoE Line 10 100Mbps Ethernet RJ 45 Simultaneous User Support over Network Monitoring Max 5 users Playback Max 5 users Management and Firmware Upgrades Firmware upgrades via Network Security Password User or Administrator Authentication Power AC Free Volt 100 240VAC Power Consumption with 2HDD Max 85W Typical 60W Environmental Spec Operating 41 ...

Страница 75: ...P construction xxx 0 255 2 Network class A class A network that contains IP addresses from 0 to 127 at room X1 Network ID X1 Host ID X2 X3 X4 Total number of A class networks is 128 in the world B class A network that contains IP addresses from 127 to 191 at room X1 Network ID X1 X2 Host ID X3 X4 Total number of B class networks is 65 534 in the world C class A network that contains IP addresses f...

Страница 76: ...te users can access local network over Internet through the gateway router Generally the second number is assigned as Gateway address Broadcast address It is to broadcast to all devices that are connected on local network Broadcast address is a destination for broadcasting and it is determined by calculating All devices connected on local network have a same Broadcast address Subnet Mask It is to ...

Страница 77: ...ddresses xxx xxx xxx 130 xxx xxx xxx 254 3 To use as three sub networks 1 4 1 4 1 2 Sub Network ID xxx xxx xxx 0 Gateway Address xxx xxx xxx 1 Subnet Mask 255 255 255 192 Broadcast Address xxx xxx xxx 63 IP Addresses xxx xxx xxx 2 xxx xxx xxx 62 Sub Network ID xxx xxx xxx 64 Gateway Address xxx xxx xxx 65 Subnet Mask 255 255 255 192 Broadcast Address xxx xxx xxx 127 IP Addresses xxx xxx xxx 66 xxx...

Страница 78: ...xxx 64 Gateway Address xxx xxx xxx 65 Subnet Mask 255 255 255 192 Broadcast Address xxx xxx xxx 127 IP Addresses xxx xxx xxx 66 xxx xxx xxx 126 Sub Network ID xxx xxx xxx 128 Gateway Address xxx xxx xxx 129 Subnet Mask 255 255 255 192 Broadcast Address xxx xxx xxx 191 IP Addresses xxx xxx xxx 130 xxx xxx xxx 190 Sub Network ID xxx xxx xxx 192 Gateway Address xxx xxx xxx 193 Subnet Mask 255 255 255...

Страница 79: ......

Страница 80: ... Center Building 191 Hanganro 2ga Yongsan gu Seoul 140 702 Korea Phone 82 2 799 6109 Fax 82 2 749 6119 E mail cctv honeywell co kr cctv honeywell com http www honeywell co kr cctv english Specifications may change at any time and without notice ...

Отзывы: