HGI 80
6.
GB
Technical Data
Operational Environment
Environmental temperature
0 – 50 °C
Air humidity
5 – 93 % not condensing
Storage:
Storing temperature
–35 – +70 °C
Air humidity
5 – 95 % not condensing
Housing protection
IP 30
Size of the housing ( cover)
90 x 90 x 28 mm
RF communication:
Frequency
868.3 MHz
Tolerance
+/–20 kHz
Deviation
+/–50 kHz
Input Ratings
max. current (low power device)
100 mA
max. power consumption according to USB
specification
5 V x 100 mA = 500 mW
Input VCC
typically 5 V DC, min. 4,4 V; max. 5,25 V
Inrush current
deltaVCC max. 330 mV (max. 10 uF II 44 Ohm)
Data lines (D+, D-)
High: nominal 3,3 V; min 2,0 V
Low: nominal 0 V; max 0,8 V
Cable Type
USB cable length max. 5 m type B
Data Transmission
NOTE: The HGI 80 is compatible with the full speed USB 2.0
specification however the USB interface transmits at a baudrate
of 115 kbaud.
Required Software Version HCM 200 D
7.0 or higher