Installing the Camera | 31
800-11873V4 - A - 07/2014
Figure 2-7
Main Alarm Adapter Input (Detail)
Connecting the Network Cable
Connect a Category 5 or higher Ethernet cable to the RJ45 connector on the back plate of the
camera (see
). The Ethernet cable should not be longer than 328 feet
(100 m). After you have connected the Ethernet cable, check the status of the LED indicators on
the RJ45 connector. If the LEDs are not lit, re-check the connection.
•
The green LED indicates a network connection.
•
The orange LED indicates network activity.
Note
You may need to use a crossover cable if you are connecting the
camera directly to a PC.
Inputs (x4)
5V, 4700 Ohms, pull up
Outputs (x2)
Relay output, 120 V AC/30 V DC, 3 A MAX
Note
Use alarm outputs for SELV circuits only.
1 2 3 4
5 6 7
8 9 10 11 12
Table 2-6
Alarm Input Pin Definitions
Pin
Definition
Pin
Definition
1
Alarm Out NO 1
7
Alarm Out COM 2
2
Alarm Out NC 1
8
GND
3
Alarm Out COM 1
9
Alarm In 4
4
GND
10
Alarm In 3
5
Alarm Out NO 2
11
Alarm In 2
6
Alarm Out NC 2
12
Alarm In 1
Содержание HDZ20HD
Страница 14: ...www honeywell com security 14 HDZ Series IP PTZ User Manual ...
Страница 16: ...www honeywell com security 16 HDZ Series IP PTZ User Manual ...
Страница 34: ...www honeywell com security 34 HDZ Series IP PTZ User Manual ...
Страница 106: ...www honeywell com security 106 HDZ Series IP PTZ User Manual ...
Страница 140: ...www honeywell com security 140 HDZ Series IP PTZ User Manual ...
Страница 158: ...www honeywell com security 158 HDZ Series IP PTZ User Manual ...
Страница 162: ...www honeywell com security 162 HDZ Series IP PTZ User Manual ...
Страница 163: ......