HCL-1PH
User’s
Manual
13
9
Technical Specifications
9.1
General features:
Cover and Socket material:
PolymericV2
Utilization Category
AC-51 AC-55a AC-55b AC-56A
IP Code
20
Method of Connecting
Single Phase Load
Auxiliary voltage:
(10 VA Max)
90:130V
170:265V
230:345V
300:530V
510:690V
600:760V
Relay output for Heater Break Alarm
(only with HB option):
0.5A a 125VAC
9.2
Input features:
Logic input SSR:
4 ÷ 30Vdc 5mA Max (ON
≥
4Vdc OFF
<
1Vdc)
Analogic input V:
0 ÷ 10Vdc impedance 15 K ohm
Analogic input A:
4 ÷ 20mA impedance 100 ohm
POT
10 K ohm min.
Digital Input
4 ÷ 24Vdc 5mA Max (ON
≥
4Vdc OFF
<
1Vdc)
9.3
Output features(power device):
Current
Nominal
Voltage
range
(Ue)
Repetitive
peak reverse
voltage
(Uimp)
Latching
current
Max peak
one cycle
Leakage
current
I
2
T value
max
Frequency
range
Power loss
Isolation
Voltage
(Ui)
(A)
(V)
(480V)
(600V)
(mAeff)
(10msec.)
(A)
(mAeff)
tp=10mse
c
(Hz)
I=Inom
(W)
Vac
60 24÷600
1200
1600 450
100
15
4750 47÷70 65
2500
90 24÷600
1200
1600 450
2000
15 19100 47÷70 84
2500
120 24÷600
1200
1600 450
1540
15
11300 47÷70 138
2500
150 24÷600
1200
1600 450
2000
15
19100 47÷70 162
2500
180 24÷600
1200
1600 300
4800
15 108000 47÷70 178
2500
210 24÷600
1200
1600 300
5250
15 128000 47÷70 202
2500
9.4
Fan Specification (only from 120 to 210A)
Supply: 230V Standard
Power 16W (1 Fan)
Supply: 115V Option
Power 14W (1 Fan)