-4-
To install the MDENR100 into a QuickNetwork panel, place the unit into the panel and align module into a free 6
inch slot with snap rivets engaged. Once the rivets are aligned with the holes, pull out the plungers and push the
module in ½ inch until it is fully seated. Secure the module in place by pushing in the plungers. Plug the power
adapter into the back of the unit and then plug the transformer into a 110V power outlet to power the unit up.
To install the HBENR100 into a SuperPro panel, remove one of the 1.75-inch blank plates to free up a slot at the
bottom of the panel. Install the HBENR100 from the front side of the SuperPro panel and secure with the four 6/32
¾-inch screws that are provided. Plug the power adapter into the back of the unit and then plug the transformer
into a 110V power outlet to power the unit up.