EN-7
EN
FILTERING HALF-MASK: INSTRUCTIONS FOR USE
Please read the user manual before using the
product.
APPLICATIONS
Particle filter half-masks classified FFP1, FFP2
or FFP3 against solid and liquid aerosols in
concentrations up to Protection Factor X WEL
(Workplace Exposure Limit):4 x WEL: FFP1
class (low toxicity),12 [10 in UK, FIN, D, I, S] x
WEL: FFP2 class (average toxicity),50[20 in
FIN, S, UK & 30 D, I] x WEL: FFP3 class (high
toxicity). «D» marked for passing the dolomite
clogging test. «NR» (single -shift use) or «R»
(re-useable) marked according to the amended
standard EN 149:2001 +A1:2009.
WEARING AND ADJUSTMENT
1
Follow these instructions each time respira-
tor is worn.
1
Cup the respirator in the hand, allowing the
head straps to hang freely.
1
Hold the respirator under the chin with the
nosepiece facing outwards. Place the lower
head strap around the neck below the ears.
1
Holding the respirator against the face with
one hand, place the top head strap above
the ears, around the crown of the head.
1
Place hands on each side of the respirator
and move slightly right, left, up and down,
to adjust the position of the respirator and
the nosepiece to achieve the most optimal
fit on the face.
FIT-CHECK THE FACE-SEAL AS FOLLOWS
1
Place both hands over the respirator - do not
disturb the position of the respirator.
1
Inhale sharply (a negative pressure should
be felt inside the respirator).
1
Exhale sharply (a positive pressure should
be felt inside the respirator).
1
If you detect air-leaks, readjust the head
straps and/or the nose-piece.
WARNING: If you cannot achieve satisfactory fit,
do NOT enter the contaminated area. See your
Supervisor.
USE INSTRUCTION
1
Failure to follow all instructions and limita-
tions concerning the use of the respirator
and/or failure to wear the respirator for the
whole duration of exposure to contaminants
can seriously reduce the performance
characteristics of the respirator and lead to
illness, injury or death.
1
Before Occupational Use of this respirator,
a written respiratory protection program
must be implemented meeting all the local
government requirements.
1
Taking a new mask from its box.
1
Check the condition of the mask before use.
1
Fit the mask and check leak-tightness
before entering the contaminated area.
1
Wear it for the whole duration of exposure to
contaminants
1
Discard the respirator and replace with a
new one if:
• it is removed while in a contaminated area,
• excessive clogging of the respirator causes
breathing difficulty or discomfort,
• the respirator becomes damaged,
• for masks offering relief against nuisance
odors, the smell becomes detectable.
1
Do not alter the mask.
1
Leave the contaminated area if dizziness,
irritation or other distress occurs.
LIMITATIONS
1
DO NOT use this mask to enter or stay in an
area where:
• oxygen concentration is less than 17%
(oxygen-deficient atmospheres),
• contaminants and/or their concentrations
are unknown or immediately dangerous to
life or health,
• aerosol concentration exceeds levels fixed
by applicable health and safety regulations
or Protection Factor x WEL,
• gases and/or vapors are present.
1
DO NOT use this mask in explosive atmos-
pheres.
1
DO NOT use before receiving training.
CHECKING BEFORE USE
The user shall ensure that the mask is suitable
for the intended application before entering the
contaminated area.
STORAGE CONDITION
1
The respirator should be stored at the area
which is well-ventilated, avoids direct sun
exposure and dry area. Keep away from fire
and pollution.
1
Storage temperature range is -20°C (-4°F)
to 38°C (100.4°F). Maximum Relative
Humidity < 80%.
1
Best before: Check on package.
WARNING
This respirator helps protect against certain
contaminants. It may not eliminate the risk of
contracting disease or infection. Misuse may
result in sickness or death.
This mask is marked “NR”, the particle filtering
half mask shall not be used for more than one
shift. Keep unused masks in their closed box
and store in a non-contaminated area.
CLEANING
Applicable only on the re-usable masks («R»).
If the mask is to be used for more than one
shift, the face seal must be cleaned with a wipe
impregnated with a cleaning and disinfecting
solution, without alcohol.
Sort out your waste by respecting the
regulations in force.
FOR MORE INFORMATION or assistance on
Honeywell products, contact your local Honey-
well distributor.
Particle filtering half mask meet the
requirements of Regulation (EU) 2016/425.
They have been tested according to EN
149:2001+A1:2009. Module B (EU type-Ex-
amination Certification) and Module C2 or
Module D Certification have been issued by
CCQS Certification Services Limited, Block 1
Blanchardstown Corporate Park, Ballycoolin
Road, Blanchardstown, Dublin15, D15 AKK1,
Ireland (NB 2834).