
GSMV4G/GSMVCN4G Installation and Setup Guide
1-4
•
Fault output: Terminal 11 can serve as a fail-safe trigger for communicator fault
conditions.
If used, the fault relay will trip when the following conditions occur: tamper*, power loss*,
low battery*, battery charger fault*, loss of network connectivity*, the device is not
registered and the device is remotely disabled by AlarmNet.
*
Alarm reporting for the noted condition must be enabled for it to trigger the fault relay.
•
Primary power loss and low battery conditions (“Pwr Loss Rpt,” “Low Bat Rpt” options).
•
Cover tamper condition (“Tamper Rpt” option).
Antenna
The communicator comes equipped with an internal antenna. This feature provides
additional security to the installation by making the device tamper resistant.
UL / ULC
External antenna has not been evaluated by UL.
AMPS antennas, such as the 7825-OC antenna, cannot be used with this product.
Содержание GSMV4G
Страница 2: ......
Страница 40: ...GSMV4G GSMVCN4G Installation and Setup Guide 4 4 ...
Страница 46: ...GSMV4G GSMVCN4G Installation and Setup Guide 5 6 ...
Страница 47: ...A 1 Appendices Appendix A Summary of LED Operation ...
Страница 48: ...GSMV4G GSMVCN4G Installation and Setup Guide A 2 ...
Страница 50: ...GSMV4G GSMVCN4G Installation and Setup Guide B 2 ...
Страница 52: ...GSMV4G GSMVCN4G Installation and Setup Guide C 2 ...
Страница 53: ...NOTES ...
Страница 54: ...NOTES ...
Страница 55: ...NOTES ...
Страница 56: ...NOTES ...
Страница 57: ...NOTES ...
Страница 58: ...NOTES ...
Страница 59: ...NOTES ...
Страница 60: ...NOTES ...
Страница 61: ...NOTES ...
Страница 62: ...NOTES ...