LCD-SLP
Liquid Crystal Display-Smart Loop Panel
Product Installation Document
Document LS10045-000GF-E:E 12/16/2019 ECN 19-0583
Section 1: Description
The LCD-SLP (Liquid Crystal Display-Smart Loop Panel) is a 4.3”(10.92 cm) diagonal, 480 x 272 pixels, color touchscreen
interface that consists of system events including indicating LEDs and control switches. It may be remotely located via a local RS-
485 serial interface. The LCD-SLP display is a remote annunciator that is compatible with the following system, modules.
The SLP-E3, ILI-MB-E3 and ILI95-MB-E3 modules support up to 15 fully-functional and supervised LCD-SLP color touchscreen
interfaces.
Firmware Compatibility
Table 1.1 lists the Firmware Compatibility for the LCD-SLP touchscreen..
Figure 1.1 illustrates the LCD-SLP touchscreen.
Figure 1.1 LCD-SLP Panel Display
!
CAUTION 1: STATIC SENSITIVE EQUIPMENT:
THIS EQUIPMENT IS SENSITIVE TO STATIC ELECTRICITY. IT MAY BE DAMAGED IF NOT PROPERLY HANDLED.
TRANSPORT AND STORE THIS UNIT IN A STATIC-SHIELDING BAG.
FAILURE TO OBSERVE THIS REQUIREMENT COULD CAUSE LATENT DAMAGE TO THE EQUIPMENT WHICH
MIGHT NOT MANIFEST ITSELF UNTIL AFTER THE EQUIPMENT IS PLACED IN SERVICE.
!
CAUTION 2: DISCONNECT ALL POWER:
REMOVE ALL SOURCES OF POWER BEFORE SERVICING, REMOVING OR INSTALLING ANY UNITS.
• S3 Series, SLP-E3
(Smart Loop Panel-Main Board)
• E3 Series
®
, ILI-MB-E3
(Intelligent Loop Interface-Main
Board)
• E3 Series, ILI95-MB-E3
(Intelligent Loop Interface95-Main Board)
NOTE:
E3 RELEASING PANEL OPERATOR INTERFACE INSTALLATION REQUIREMENTS:
The LCD-SLP display panel includes optional audio/visual signaling capabilities for the E3 Series Releasing application. The
E3 Releasing application contains an RS-485 circuit to support the connection of up to fifteen LCD-SLP displays. In
CAMWorks, you must configure at least one LCD-SLP as a Releasing panel operator interface.
CAMWorks Firmware
Version
ILI-MB-E3
First Generation
ILI-MB-E3
Second Generation
SLP-E3
Firmware Version
LCD-SLP
Firmware Version
Minimum Firmware Version
CAMWorks Version
3.40 or later.
Firmware Version
3.3 or later.
Water release only.
Firmware Version
4.3 or later.
Firmware Version
1.21 or later.
Firmware Version
2.10 or later.
UL 864 10th Edition Standard
For UL 864 10th Edition
compliance, use, use
Firmware
Version
3.52 or later.
For UL 864 10th Edition
compliance, use
Firmware
Version
4.10 or later.
For UL 864 10th Edition
compliance, use
Firmware
Version
4.10 or later.
For UL 864 10th Edition
compliance, use
Firmware
Version
1.21 or later.
For UL 864 10th Edition
compliance, use
Firmware
Version
2.12 or later.
Table 1.1 Firmware Versions