background image

 

OPERATOR MANUAL // LIMITED WARRANTY 

 

HONEYWELL  

26 

Limited Warranty 

Honeywell Analytics warrants its Products against defects in material and workmanship under normal 
use and service for a period of two (2) years from the date of shipment as described herein. Honeywell 
Analytics, at its option, will repair or replace, at no charge, such products found to be defective during 
the warranty period provided that they are returned in accordance with the terms of this warranty. 
Replaced parts or boards are warranted for the balance of the original applicable warranty period. All 
Replaced parts of Products shall become the property of Honeywell Analytics. This express limited 
warranty is extended by Honeywell Analytics to the original purchaser only and is not assignable or 
transferable to any other party. This is the complete warranty for the Products manufactured by 
Honeywell Analytics. Honeywell Analytics assumes no obligations or liability for additions or 
modifications to this warranty unless made in writing and signed by an officer of Honeywell Analytics. 
Honeywell Analytics does not warrant the installation, maintenance or service of its Products. Honeywell 
Analytics is not responsible in any way for ancillary equipment not furnished by Honeywell Analytics, 
which is attached to or used in connection with its Product(s), or for operation of the Product(s) with 
ancillary equipment and all such equipment if expressly excluded from this warranty. This warranty sets 
forth the full extent of Honeywell Analytics’ responsibility regarding the Products’ repair or replacement 
at Honeywell Analytics’ options, is the exclusive remedy.  
 
This Warranty is given in lieu of all other Express Warranties, Implied Warranties, including without 
limitation, Implied Warranties of Merchantability and fitness for a particular purpose, are limited to the 
duration of this Limited Warranty. In no other event shall Honeywell Analytics be liable for damages in 
excess of the purchased price of the product(s), for any loss of use, loss of time, inconvenience, 
commercial loss, lost profits or savings or other incidental, special or consequential damages arising out 
of or in connection with the use or inability to use such product, to the full extent such may be 
disclaimed by law.  
 
THIS WARRANTY DOES NOT COVER:  
1. Defects or damage resulting from use of the Product(s) in other than its normal and customary 

manner.  

2. Defects or damage from misuse, accident, or neglect.  
3. Defects or damage from improper testing, operation, maintenance, installation, alteration, 

modification or adjustment.  

4. Product(s) subject to unauthorized Product modifications, disassemblies or repairs (including, without 

limitation, the audition of the product of non-Honeywell Analytics supplied equipment) which 
adversely affect performance of the Product(s) to interfere with Honeywell Analytics’ normal warranty 
inspection and testing of the Product(s) to verify any warranty claim.  

5. Product(s) that have had the serial number removed or made illegible.  
6. Freight cost to the repair facility.  
7. A Product which due to illegal or unauthorized alteration of the software/firmware in the Product, does 

not function in accordance with Honeywell Analytics’ specifications.  

8. Scratches or other cosmetic damage to Product surfaces that do not affect the operation of the 

Product.  

9. Normal and customary wear and tear.  
 
Laws in the United States and other countries preserve for Honeywell Analytics certain exclusive rights 
for copyrighted Honeywell Analytics software/firmware, such as the exclusive rights to reproduce in 
copies and distribute copies of such Honeywell Analytics software/firmware. Honeywell Analytics 
software/firmware may be used only in the Product(s) in which the software/firmware was originally 
embodied and such software/firmware in such Product(s) may not be replaced, copied, distributed, 
modified in any way, or used to produce any derivative thereof. No other use including, without 
limitation, alteration, modification, reproduction, distribution, or reverse engineering of such Honeywell 
Analytics software/firmware or exercise or rights in such Honeywell Analytics software/firmware is 
permitted. No license is granted by implication, estoppel or otherwise under Honeywell Analytics patent 
rights or copyrights. 

 
 

Содержание FS10-R

Страница 1: ...d Operating Manual Multi Spectral Digital Infrared Electro Optical Fire Detector Unitized Two Stage Quick Response FSC Model Nos FS10 R FS10 RN with Wide Band IR FS System 10TM Digital Fire Detection Process Control System ...

Страница 2: ...tical Path Integrity CM1 CM1 A DartLogic FireLogic Honeywell Analytics VSD 8 Honeywell Analytics VSD 8 Visual Smoke Detection System VSD 4 VSD 8 Fire Signature Analysis FireBusI FireBusII FirePic FirePicII FirePicIII FirePix FirePicture FSC Honeywell Analytics Honeywell Analytics FSX All FSX Nomenclature Variations such as FS2 FS2X FS3 FS3X FS4 FS4X FS5 FS5X FS6 FS6X FS7 FS7X FS8 FS8X FS9 FS9X FS1...

Страница 3: ...OPERATOR MANUAL NOTICES AND TRADEMARKS HONEYWELL 3 Other brand or product names are trademarks of their respective owners Honeywell Analytics ...

Страница 4: ...ut This Document Read and understand this manual before installing or operating equipment No part of this document may be copied or reproduced without the express written permission of Honeywell Analytics This manual is subject to change without notice ...

Страница 5: ...this booklet REFERENCE INTERNAL Identifies an additional source of information within this booklet Indicates a situation which if not avoided may result in equipment or work data on the system being damaged or lost or may result in the inability to properly operate the process CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may als...

Страница 6: ...duit Installation 13 2 3 Power Supply Considerations 14 2 4 Mounting the Flame Detectors 14 SECTION 3 OPERATING MODES 15 3 1 Normal Operation 15 3 2 Alert Fire Early Warning 15 3 3 Alarm Condition 15 3 4 Fault Condition 15 3 5 Automatic Detector Test 16 3 6 Manual Detector Test 16 3 7 Advanced System Diagnostics 16 SECTION 4 MAINTENANCE AND REPLACEMENT 17 4 1 Detector Faults 17 4 2 Cleaning Detect...

Страница 7: ...OPERATOR MANUAL TABLE OF CONTENTS HONEYWELL 7 Index 25 Limited Warranty 26 Contact Honeywell Analytics 27 Americas 27 Europe 27 Asia Pacific 27 Internet 27 Telephone 27 ...

Страница 8: ...llers The FS10 line of Detectors is designed primarily for indoor fire detection applications where combustible materials exist Typical applications include Automotive Paint Lines Aerosol Filling Paint Kitchens General Finishing Curing Ovens Paint Mixing Rooms Powder Coating Booths Warehouse Storage Compressor Modules Liquid Paint Spray Lines Diesel Generators Internal Storage Tanks 1 2 Responses ...

Страница 9: ...nt energy sources The Detector simultaneously The Detector is factory set for Alert Fire Early Warning and Fire Alarm detection range of 15 feet FS10 R15 RN15 and 30 feet FS10 R30 RN30 to a one square foot Heptane reference pan fire The Alert response time is factory set to 0 3 second the Fire Early Warning response time is factory set to 1 0 second and The Fire Alarm response time is factory set ...

Страница 10: ...with closed contacts The Detector contains one Fire Alarm relay with a contact rating of 1 Amp 24 VDC The relay is de energized with open contacts during Normal Operation During a Fire Alarm condition the relay is energized with closed contacts Note 1 6 3 Fault Relay Output The Fire Relay may be ordered configured in a Latching or Non Latching mode If Latching mode is configured the Fire Relay wil...

Страница 11: ...l and vertical 1 6 6 Environment Range The Detector humidity range is 10 to 90 RH non condensing The operating and storage temperature range of the Detector is 40 o F to 185 o F 40 o C to 85 o C 1 6 7 Location For proper installation each Detector should be located within the detection distance ordered from the factory i e 15 feet for the FS10 R15 RN15 A15 AN15 30 feet for the FS10 R30 RN30 A30 AN...

Страница 12: ...TION 2 1 Detector Views The Detector may be mounted directly on the wall or with the optional SM2 swivel mounting assembly or SM4 Stainless Steel Swivel Mount refer to Section 6 1 for details 2 09 4 66 1 10 0 67 4 38 2 40 NPT 1 50 Figure 3 Fire Detector Housing Side View ...

Страница 13: ...ION 1S GF 240 Connect 240 Volts AC LAST 2 2 Conduit Installation Detectors should be located to cover the specific fire threat areas When planning the conduit observe the following recommendations 1 If only one of the two inch NPT conduit openings of the Detector enclosure is used appropriately seal the unused opening with a threaded tapered plug 2 In areas where moisture may accumulate install an...

Страница 14: ...upply the panel s power supply must be able to handle at least 1 20 Amps This load current must also be considered when calculating the panel requirements for 24 hour backup 2 4 Mounting the Flame Detectors The Flame Detectors have the ability to see a one square foot heptane pan fire at half of the Detector s sensitivity off axis out to 45 degrees for a 90 degree Field of view viewing angle It is...

Страница 15: ...y blink the red LED continuously energize the Alert Early Warning energize the relay or indicate a 12 mA output current record FirePic in non volatile memory record the event in the Event History file in non volatile memory 3 3 Alarm Condition During a Fire Alarm condition the Detector will turn ON the red LED continuously Energize the Fire Alarm energize the relay record FirePic in non volatile m...

Страница 16: ...or s front cover is not installed Note 3 6 Manual Detector Test While ACCTTL tests are occurring the system is still functional and able to alarm to a fire WARNING Responses to the FS10 R Detector relay output must be isolated mechanically not solely by programming the control panel using software or firmware This will avoid external alarms and or suppression discharge when performing the followin...

Страница 17: ...nded action Use an air Event History File Action Fault CONDITION 1 No LED illumination No power is available at the Detector Check wiring for broken or crimped cables or loose terminations Fault CONDITION 3 LED blinks 3 times Flame Detector through the lens test failure Clean the lens and grill It is important to clean underneath the grill See Section 3 5 Fault CONDITION 5 LED blinks 5 times Flame...

Страница 18: ...touch the sensor windows 5 Using a small screwdriver turn the two clamp screws counter clockwise that secures the ten wire cable plug so the plug may be removed 6 Handle the Flame Detector Module with care and do not touch the sensor windows 7 Carefully wrap the Module in static protection material if none available use aluminum foil and ship to Honeywell Analytics 8 To install a Detector Module j...

Страница 19: ...ault Relay Contact A Normally energized CLOSED 6 Fault Relay Contact B Normally energized CLOSED 7 Alarm Relay Contact A Normally OPEN 8 Alarm Relay Contact B Normally OPEN 9 Alert Early Warning Relay Contact A Normally OPEN 10 Alert Early Warning Relay Contact B Normally OPEN Table 2 Flame Detector Connector Pin outs for FS10 R type Detectors J1 Connector FIRE DETECTOR Module ...

Страница 20: ...rmally energized CLOSED 7 Alarm Relay Contact A Normally OPEN 8 Alarm Relay Contact B Normally OPEN 9 Not used 10 Not Used Table 3 Flame Detector Connector Pin outs for FS10 R45 type Detectors DO NOT CONNECT SHIELD AT THE FLAME DETECTOR Note COMM as it is used in this document is an abbreviation for Communications Detector relays are shown as they are during Normal Operation that is there are no F...

Страница 21: ...OPERATOR MANUAL SECTION 5 PINOUT DATA HONEYWELL 21 1 2 3 4 5 6 7 8 9 10 Figure 3 FS10 R Detector Module Connector Rear View ...

Страница 22: ...ION 6 ACCESSORIES HONEYWELL 22 SECTION 6 ACCESSORIES 6 1 Detector Heavy Duty Swivel Mount Part No SM2 4 86 4 26 2 95 2 00 0 295 Dia 4 7 approx Figure 4 Detector Swivel Mount Figure 5 Model SM4 Stainless Steel Swivel Mount ...

Страница 23: ...ance for end users with a planned maintenance schedule Should debris collect these specifically designed protective covers may be easily replaced The task of cleaning the Detector viewing windows for proper operation is eliminated 6 4 Extension Pole for Disposable Covers Part No EXPL 1 thus reducing maintenance requirements A regularly scheduled maintenance plan can virtually eliminate the need to...

Страница 24: ...echargeable battery terminal box with two connecting cables a 120 VAC wall transformer for recharging the battery and User PC software interface Kit allows access to post event analysis FirePic as well as monitoring the Detector s operation SnapShot Post event analysis includes the Detector s time and date stamp of ALERT ALARM and FAULT histories Event History Note The PC Interface Kit may also be...

Страница 25: ...OPERATOR MANUAL INDEX HONEYWELL 25 Index Controller Fault 17 Detector Cable 19 Cleaning 17 Input Power Milliamps 8 Test Lamp 23 Through the Lens Fault 17 ...

Страница 26: ...venience commercial loss lost profits or savings or other incidental special or consequential damages arising out of or in connection with the use or inability to use such product to the full extent such may be disclaimed by law THIS WARRANTY DOES NOT COVER 1 Defects or damage resulting from use of the Product s in other than its normal and customary manner 2 Defects or damage from misuse accident...

Страница 27: ...olon Science Valley 1 43 Digital Ro 34 Gil Guro Gu Seoul 152 729 Korea Email analytics ap honeywell com Internet These Honeywell websites may be of interest to Industry Solution customers Honeywell Organization URL Corporate www honeywell com Honeywell Analytics www honeywellanalytics com Telephone Contact us by telephone at these numbers Organization Phone Number Americas Honeywell Analytics Inc ...

Страница 28: ...1998M0950 Revision A July 2014 2014 Honeywell International Inc ...

Отзывы: