INSTALLATION AND CHECKOUT

When Installing this Product…

1. Read these instructions carefully. Failure to follow them

could damage the media air filter or cause a hazardous
condition.

2. Check the ratings given in the instructions and on the

media air cleaner to make sure the product is suitable
for your application.

3. Installer must be a trained, experienced service

technician.

Remove Furnace Filter And Clean Blower
Compartment

Before starting the installation, remove and discard the
existing furnace filter (if used). Thoroughly clean the blower
compartment. If possible, power vacuum the ductwork to
remove accumulated dust in an occupied home or remove
construction dirt in a new home. The media air cleaner cannot
remove dirt that has settled in the blower compartment and
distribution ducts.

Install The Cabinet

The following procedure describes a typical side installation
on an existing highboy furnace. Alternate procedures are
noted as appropriate. Other changes in installation
procedures may be necessary to complete your installation.

Review The Installation Plan

Temporarily place the cabinet on the floor, oriented as it will
be when installed. Insert and remove the cartridge to make
sure the plan allows adequate clearance for easy removal
and replacement of the cartridge.

Make sure that shop-fabricated sheetmetal components, such
as turning vanes, are available.

Fasten The Cabinet To The Furnace

Align the cabinet with the return air opening. Place blocks
under the cabinet, as necessary, to make sure the unit sits
securely. Create an opening in the furnace to match the
cabinet opening. Attach the cabinet securely to the furnace.
Attach the unit directly or fit a starting collar in the furnace
opening. Either drill holes and fasten with sheetmetal screws
or rivets, or use slip joints. If you are drilling holes, use a
locking pliers to help hold the unit in place during drilling.

Install Turning Vanes

Install turning vanes to help distribute air equally over the full
surface of the upstream side of the media. Install them
whenever an abrupt 90 degree elbow is installed directly
against the media air cleaner cabinet.

Fasten Cabinet To Ductwork

Fasten side of cabinet to the ductwork using sheet-metal
screws, rivets, or slip joints, as appropriate.

Connect Ductwork

Connect the vertical duct section to the elbow. If the vertical
drop of the duct is less than 7 in. (178 mm) from the side of
the furnace, shorten the horizontal trunk or attach an offset
fitting to the elbow. See Fig. 12. When ductwork is properly
aligned, connect the vertical duct to the horizontal trunk.

Seal Joints

Seal all joints in the return air system between the media air
filter and the furnace to prevent dust from entering the clean
airstream.

Install Filter Cartridge

Slide the filter cartridge into the cabinet, making sure the
arrow on the cartridge points in the direction of air flow.

Replace access door. Insert the tab on the bottom of the door
into the slot in the cabinet. Swing the door closed and press it
into place.

Install RF AIRWATCH™ Indicator

The AIRWATCH Indicator provides a signal when the F200F
filter needs replacing. When the filter begins restricting airflow
because of accumulated dirt, pressure sensors in the F200E
initiate a radio frequency signal to be sent to the AIRWATCH
Indicator. The AIRWATCH Indicator also provides the
capability to track when the humidifier pad and the ultraviolet
air treatment lamps need replacing.

To set up the AIRWATCH Indicator to accept signals
from the F200E transmitter:

1.

Push and hold the AIRWATCH Indicator button until all
four arrows come on (about five seconds).

2.

Push the reset button on the F200E door within two
minutes.

3.

Observe that the Indicator arrows continue to flash for
about two minutes and then automatically reset.

The AIRWATCH Indicator default setting is UV Light and
Humidifier timers are disabled; the Filter indicator is always
enabled. To display active timers:
1. Press and hold the button on the AIRWATCH Indicator for

about three seconds.

2. Observe the arrow showing the active timer(s).

To activate a timer:
1. Press and release the AIRWATCH Indicator button until

the desired device is selected, as indicated with the
flashing arrow.

2. Press and hold the button until the arrow stops flashing.
3. Release the button while the arrow is on.

Содержание F200E

Страница 1: ...reased pressure drop threshold at filter Filter change status is transmitted to wall mounted AIRWATCH Indicator The RF AIRWATCH Indicator is included SPECIFICATIONS IMPORTANT The specifications in this publication do not include normal manufacturing tolerances therefore an individual unit may not exactly match the listed specifications This product is tested and calibrated under closely controlled...

Страница 2: ...ated for greater media capacity Filter Element Underwriters Laboratories Inc UL 900 Class 2 Listed Capacity And Pressure Drop See Fig 2 Initial Pressure Drop 0 177 in wc at 492 fpm Temperature Rating 40 to 140 F 40 to 60 C Dimensions See Fig 1 Fig 1 Installation dimensions in in mm of air cleaner Mounting Mounts in any position in the return air duct usually next to the furnace blower compartment ...

Страница 3: ...ton on the F200E door to reset both the door indicator light and the RF AIRWATCH Air Cleaner Indicator See Table 1 for AIRWATCH operation Fig 2 Capacity Pressure Drop and Area of F100F Filter Media PLANNING THE INSTALLATION Location The media air cleaner should be installed where all the air passing through the system is circulated through it The best location is in the return air duct next to the...

Страница 4: ...ing in closet door Fig 6 Lowboy furnace with media air cleaner mounted horizontally in return plenum just above furnace and opposite heating plenum Fig 7 Counterflow furnace with media air cleaner mounted horizontally in return duct or plenum just above furnace M941A Fig 8 Central fan installation with media air cleaner mounted horizontally in central return duct M14788 M14789 M14790 ...

Страница 5: ... of expansion on each side of a transition fitting Turning Vanes If the media air cleaner is installed next to an elbow or angle fitting add turning vanes inside the angle to distribute airflow more evenly across the face of the media See Fig 12 Offsets If the duct connection to the furnace in a side installation allows less than 7 in 178 mm for mounting media air cleaner cabinet attach an offset ...

Страница 6: ...ll them whenever an abrupt 90 degree elbow is installed directly against the media air cleaner cabinet Fasten Cabinet To Ductwork Fasten side of cabinet to the ductwork using sheet metal screws rivets or slip joints as appropriate Connect Ductwork Connect the vertical duct section to the elbow If the vertical drop of the duct is less than 7 in 178 mm from the side of the furnace shorten the horizo...

Страница 7: ... again at step 2 Mount AIRWATCH Indicator 1 Remove the AIRWATCH Indicator from the base a Depress the tab on the bottom edge of the base b Pull off the bottom of the front cover 2 Position the base on the wall in the desired mounting position using the holes in the base as a template mark the locations for the anchors and screws provided Also mark location of round hole in center of base when usin...

Страница 8: ...e 1 AIRWATCH Indicator LCD Description AIRWATCH Indicator Condition Meaning Action No indicator on AIRWATCH has no power replace battery On Battery indicator on continuously AIRWATCH is functioning normally On Battery indicator flashing Flashing two seconds on six seconds off Replace battery in the F200E door Do not press any reset buttons after battery change Flashing two seconds on two seconds o...