Application Manual
23
Application settings
3.
Parameters can be set for optimum operation and control performance of the system in the specific application.
Underfloor heating
Parameter
Settings / range
Min/max temperature setpoint
5 ... 35 °C
Radiator heating
Parameter
Settings / range
Optimisation
Enabled / disabled
Window function
Enabled / disabled
Min/max temperature setpoint
5 ... 35 °C
Local override
Enabled / disabled
Mixing valve
Parameter
Range
Default setting
Mixing valve run time
0 ... 240 s
150 s
Pump run time
0 ... 99 min
15 min
Minimum flow temperature
0 ... 50 °C
15 °C
Maximum flow temperature
0 ... 99 °C
55 °C
Zone valves
Parameter
Settings / range
Fail save
Enabled / disabled
Min/max temperature setpoint
5 ... 35 °C