Page 24 of 52
02/2011
E
N
G
L
I
S
H
30-Arming and disarming
All delays are expressed in seconds.
Total Set
Partial Set
Annex Set
All Sets
Entry delay
3013
331 126
3113
341 128
3213
024 231 128
30 secs
Entry beeps
3012
331 220
3112
341 222
3212
024 231 225
30 secs
Exit delay
3023
332 223
3123
342 121
3223
024 232 221
60 secs
Exit beeps
3022
332 327
3122
342 225
3222
024 232 328
56 secs
Delay behaviour is determined by the following attributes:
Annex linked to total on arming
3301
024 328
0 = Independent
1 = Armed with total
0
Annex linked to total on disarming*
3302
024 922
0 = Independent
1 = Disarmed with total
0
Arm if perimeter open
3303
0251 120
0 = Allowed
1 = Forbidden
0
* Software version I12 or higher
40-Audio signals
Chime
4001
02532 621
0 = Disabled
1 = Enabled
1
50-Alarm Confirmation
Alarm Confirmation
5001
0252 324
0 = No
1 = Yes
0
51-Restoring
To perform an engineer reset, type in code 0258 152 199, then enter extra parameter 0.
Tamper reset
5101
0251 320
0 = Automatic, 1 = By Engineer
0
Reset with anticode (system lock)
5102
02301 0121
Enabled = 1, Disabled = 0
0
Algorithm key for anticode
5103
02301 0325
0 to 255
0
70-Transmission
Transmitter
7001
1129
0 = Inactive
1 = PSTN
2 = GSM/Ethernet Module
3 = PSTN+GSM/Ethernet Module
0
PSTN Prefix
7103
13146
Up to 17 characters (“+” should be replaced by “00”)
-
GSM PIN Code
7204
14148
4 digits
0000
APN #1
7211
14415
Up to 30 characters
-
APN #1 Login
7212
14518
Up to 20 characters
-
APN #1 Password
7213
14611
Up to 20 characters
-
APN #2
7221
14817
Up to 30 characters
-
APN #2 Login
7222
14910
Up to 20 characters
-
APN #2 Password
7223
140 1019
Up to 20 characters
-
Alarm sent if Partial set
7002
025 529
0 = not sent
1 = sent
0