SDC / DHC
Operation
EN2H-0220GE51 R0308
37
The switch-off time cannot be set higher than the switch-on time
of a subsequent cycle.
If the switch-on time is changed, the corresponding time bar
display is adjusted to the right-hand side.
If the switch-off time is made equal to the switch-on time, the
corresponding cycle is deleted. A subsequent cycle is
automatically shifted to the position of the deleted cycle upon
acceptance.
With subsequent insertion of a cycle that has been bumped up,
the corresponding day of the week must be reprogrammed.
A flashing switch-off time is accepted by pressing the input button
î
.
Pos: 35 /156-Honeywell/Bedienung/Zyklustemperatur @ 1\mod_1207645359213_6.doc @ 9645
4.2.2.4.3 Cycle
temperature
Once the switch-off time is accepted, the associated cycle
temperature appears flashing and can be changed immediately
with the input button
î
. With heating circuits, the displayed cycle
temperature is always based on the desired room temperature;
with the hot-water circuit, it is based on the desired normal hot-
water temperature in the selected cycle.
A flashing cycle temperature is accepted by pressing the input
button
î
.
At the same time, the last called-up cycle appears flashing so that
it may be monitored; additional cycles can then be selected
directly and edited in the same way in the order: switch-on time,
switch-off time, cycle temperature.
Pos: 36 /156-Honeywell/Bedienung/Schaltzeitenprogrammierung_gesperrt @ 1\mod_1207645477385_6.doc @ 9660
NOTE
Содержание DHC
Страница 1: ...EN2H 0220GE51 R0308 Heating Controller SDC Remote Heating Controller DHC OPERATING INSTRUCTIONS ...
Страница 2: ...EN2H 0220GE51 R0308 ...
Страница 5: ...SDC DHC Contents EN2H 0220GE51 R0308 5 ...
Страница 6: ......
Страница 61: ...SDC DHC Log EN2H 0220GE51 R0308 61 ...
Страница 62: ...Log SDC DHC 62 EN2H 0220GE51 R0308 ...
Страница 63: ......