First   
Digit

Cycle Rate Setting

(cph at 50% On Time)

0 or 1

1

2 or 3

3

4 or 5

9

6 or 7

6

Second

Digit

Clock

(hr)

Degrees

Recovery   

Setting

0

12

F

Conventional

1

12

C

Conventional

2

12

F

Adaptive Intelligent
Recovery™

3

12

C

Adaptive Intelligent
Recovery™

4

24

F

Conventional

5

24

C

Conventional

6

24

F

Adaptive Intelligent
Recovery™

7

24

C

Adaptive Intelligent
Recovery™

Third Digit

System Switch Position

0

OFF

2

COOL

4

HEAT

System   

Press   

Look For This Response

Switch

Position

This   

Key

Key

Down

Key  
Released

OFF

03

Blank

07

Blank

15

Blank

COOL (with
fan in
AUTO)

15

Cooling and fan
on.

15

Colling and fan
off.

OFF

06

Blank

02

Blank

05

Blank

04

Blank

01

Blank

00

Blank

(CHECK
EACH
POSITION)

12

See note A

OFF

08

Blank

13

Microprocessor
mask no. and
revision no.

09

Blank

14

Blank

HEAT

14

Heating on.

1

14

Heating off.

OFF

10

Blank

11

Normal operating
display.

CHANGE

TO LAST

PERIOD

SKIP

NEXT

PERIOD

PRESENT

SETTING

PRESENT

SETTING

PRESENT

SETTING

WARMER

COOLER

AHEAD

RETURN

LEAVE

BACK

WAKE

SLEEP

DAY

SET

HEAT/COOL

SET

PRESENT
DAY/TIME

SET

PRESENT
DAY/TIME

SET

PRESENT
DAY/TIME

HOLD

TEMP

RUN

PROGRAM

END SELF-TEST

1

For electric heat fan operation, the fan operates with
the heating system when the fan switch is in AUTO.

A HEAT displayed when system switch is in HEAT,

COOL when in COOL, neither when in OFF. A four-
digit code is displayed with each digit explained as
follows.

Fourth Digit

System Switch Position

0

Any position

1

HEAT, OFF, or COOL

4

Any position

5

HEAT, OFF, or COOL

Allow thermostat to reach room temperature before pro-
gramming. Then refer to owner’s manual for programming
instructions and homeowner troubleshooting.

This equipment is a Class B digital apparatus which complies with Canadian Radio Interference Regulations, CRC c. 1374.

Содержание CT8602C

Страница 1: ...prevent drafts from affecting thermo stat operation LOCATION Install thermostat and wallplate about 5 ft 1 5m above the floor in an area with good air circulation at room temperature Do not install the thermostat where it may be affected by drafts or dead spots behind doors in corners or under cabinets hot or cold air from ducts radiant heat from sun or appliances concealed pipes and chimneys unhe...

Страница 2: ...event electrical shock or equipment damage The shape of the terminal barrier permits insertion of straight or conventional wraparound wiring connections Either method is acceptable Refer to Table 1 and Fig 4 through 8 for wiring guide lines NOTE Keep all wiring restricted to ribbed area surrounding terminals Fig 3 to assure thermostat wallplate contact TABLE 1 TERMINAL CROSS REFERENCE FOR STRAIGHT...

Страница 3: ...onalrecovery an indicator appears in the lower right corner of the thermo stat display as a reminder that the Adaptive Intelligent Recovery feature is not active Fig 10 Fig 10 Conventional recovery indicator SETTING TIME TEMPERATURE The display readout can be converted between a 12 and 24 hour clock or C and F using screws 2A and 2B as indicated in Fig 9 INSTALLING BATTERIES Power is supplied for ...

Страница 4: ...splay will read 1 00 PM and room tempera ture It will go off for a few seconds then begin to flash on and off Press Press TIME or to set the current time Press Press to set the current day Each press of the DAY KEY advances the display one day If the display does not come on Check mounting of thermostat to wallplate If loose or misaligned remove thermostat and reinstall on wallplate making sure it...

Страница 5: ...about 10 F 6 C below room tempera ture The heating equipment should shut off COOLING CAUTION Do not operate cooling if outdoor temperature is below 50 F 10 C Refer to manufacturer s rec ommendations NOTE When cooling setting is changed thermostat will wait up to five minutes before turning on the air condi tioner This delay protects the compressor Move the system switch to COOL and the fan switch ...

Страница 6: ...nk 04 Blank 01 Blank 00 Blank CHECK EACH POSITION 12 See note A OFF 08 Blank 13 Microprocessor mask no and revision no 09 Blank 14 Blank HEAT 14 Heating on 1 14 Heating off OFF 10 Blank 11 Normal operating display CHANGE TO LAST PERIOD SKIP NEXT PERIOD PRESENT SETTING PRESENT SETTING PRESENT SETTING WARMER COOLER AHEAD RETURN LEAVE BACK WAKE SLEEP DAY SET HEAT COOL SET PRESENT DAY TIME SET PRESENT...

Отзывы: