Fig. 2—Mounting wallplate on wall.

Fig. 4—CT8602C heating-only circuit in a
continuous pilot gas system.

Fig. 6—CT8602C heating/cooling circuit in a
single transformer system with gas heat and
electric cooling or electric heat and electric
cooling, RC and R terminals.

L1 
(HOT)

L2

1

1

Y

RC

R

G

W

FAN RELAY

24V

WALLPLATE

M121A

FACTORY-
INSTALLED
JUMPER

GAS
VALVE

POWER SUPPLY. PROVIDE DISCONNECT MEANS 
AND OVERLOAD PROTECTION AS REQUIRED.

Fig. 5—CT8602C heating-only circuit in an oil
system.

L1 
(HOT)

L2

1

1

Y

RC

R

G

W

T

T

OIL PRIMARY

M122

WALLPLATE

POWER SUPPLY. PROVIDE DISCONNECT MEANS 
AND OVERLOAD PROTECTION AS REQUIRED.

FACTORY-
INSTALLED
JUMPER

WIRES THROUGH
WALL OPENING

WALL 

WALL
ANCHORS
(2)

WALLPLATE

MOUNTING
HOLES (3)

MOUNTING
SCREWS (2)

USE TWO MOUNTING HOLES THAT
BEST FIT APPLICATION.

1

1

M2917

WIRING

All wiring must comply with local electrical codes and

ordinances.

Disconnect power before wiring to prevent electrical

shock or equipment damage.

The shape of the terminal barrier permits insertion of

straight or conventional wraparound wiring connections.
Either method is acceptable.

Refer to Table 1 and Fig. 4 through 8 for wiring guide-

lines.

NOTE: Keep all wiring restricted to ribbed area surrounding

terminals (Fig. 3) to assure thermostat/wallplate contact.

TABLE 1—TERMINAL CROSS REFERENCE.

FOR STRAIGHT
INSERTION –
STRIP 5/16 in. [8 mm]

FOR WRAPAROUND –
STRIP 7/16 in. [11 mm]

RESTRICT
WIRING TO
THIS AREA  

WIRING TO BE BELOW
THIS SURFACE

TOP SURFACE
OF SUBBASE

FRONT VIEW OF

TERMINAL AREA

CROSS-SECTIONAL VIEW OF

TERMINAL AREA

M2927

Fig. 3—Keep wiring restricted to ribbed area
surrounding terminals.

Old Thermostat

Terminal Marked

Function

New Thermostat

Terminal Marked

G or F

Fan

G

Y or C

Cooling

Y

W or H

Heating  

W

RC, V, VC or R

Power

RC

RH, M, VR, 4

Power

R

L2

1

2

2

1

Y

RC

R

G

W

24V

M119

L1 
(HOT)

COOLING
CONTACTOR

HEATING
PRIMARY
CONTROL

FAN RELAY

WALLPLATE

POWER SUPPLY. PROVIDE DISCONNECT MEANS 
AND OVERLOAD PROTECTION AS REQUIRED.

PRIMARY CONTROL SUCH AS GAS VALVE OR
ELECTRONIC IGNITION MODULE.

FACTORY-
INSTALLED
JUMPER

Содержание CT8602C

Страница 1: ...prevent drafts from affecting thermo stat operation LOCATION Install thermostat and wallplate about 5 ft 1 5m above the floor in an area with good air circulation at room temperature Do not install the thermostat where it may be affected by drafts or dead spots behind doors in corners or under cabinets hot or cold air from ducts radiant heat from sun or appliances concealed pipes and chimneys unhe...

Страница 2: ...event electrical shock or equipment damage The shape of the terminal barrier permits insertion of straight or conventional wraparound wiring connections Either method is acceptable Refer to Table 1 and Fig 4 through 8 for wiring guide lines NOTE Keep all wiring restricted to ribbed area surrounding terminals Fig 3 to assure thermostat wallplate contact TABLE 1 TERMINAL CROSS REFERENCE FOR STRAIGHT...

Страница 3: ...onalrecovery an indicator appears in the lower right corner of the thermo stat display as a reminder that the Adaptive Intelligent Recovery feature is not active Fig 10 Fig 10 Conventional recovery indicator SETTING TIME TEMPERATURE The display readout can be converted between a 12 and 24 hour clock or C and F using screws 2A and 2B as indicated in Fig 9 INSTALLING BATTERIES Power is supplied for ...

Страница 4: ...splay will read 1 00 PM and room tempera ture It will go off for a few seconds then begin to flash on and off Press Press TIME or to set the current time Press Press to set the current day Each press of the DAY KEY advances the display one day If the display does not come on Check mounting of thermostat to wallplate If loose or misaligned remove thermostat and reinstall on wallplate making sure it...

Страница 5: ...about 10 F 6 C below room tempera ture The heating equipment should shut off COOLING CAUTION Do not operate cooling if outdoor temperature is below 50 F 10 C Refer to manufacturer s rec ommendations NOTE When cooling setting is changed thermostat will wait up to five minutes before turning on the air condi tioner This delay protects the compressor Move the system switch to COOL and the fan switch ...

Страница 6: ...nk 04 Blank 01 Blank 00 Blank CHECK EACH POSITION 12 See note A OFF 08 Blank 13 Microprocessor mask no and revision no 09 Blank 14 Blank HEAT 14 Heating on 1 14 Heating off OFF 10 Blank 11 Normal operating display CHANGE TO LAST PERIOD SKIP NEXT PERIOD PRESENT SETTING PRESENT SETTING PRESENT SETTING WARMER COOLER AHEAD RETURN LEAVE BACK WAKE SLEEP DAY SET HEAT COOL SET PRESENT DAY TIME SET PRESENT...

Отзывы: