background image

4

 WIRE AND MOUNT NEW THERMOSTAT

Turn the temperature setting knob to 65

°

F (18

°

C).

This will  prevent accidental damage to the knob

stop during mounting.

Remove thermostat cover by grasping the top and
bottom ends with fingers, and pulling outward.

Connect wires to the thermostat as shown in the
applicable wiring diagram. Push  the wires into the

outlet box, and insert the thermostat into the box for
mounting by pushing against top and bottom of the
thermostat base.

IMPORTANT: 

Do not press on setting knob.

Secure the thermostat to the box with the two
captive mounting screws provided.

Replace thermostat cover.

Set knob to desired room temperature.

I

MPORTANT: 

Rough handling or strong pressure can

damage knob or sensing element, and change
calibration.

69-0829—1

2

5

5

60

65

70

75

8

0

8

5

o

 F

M8422

L1 
(HOT)

L2

1

1

1

2

3

4

3

2

4

4

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD 
PROTECTION AS REQUIRED.

BREAKS ON POSITIVE OFF.
 
EXPOSED UNUSED LEADWIRES TO BE PROPERLY INSULATED.

THERMALLY ACTIVATED—BREAKS ON TEMPERATURE 
RISE. MAKES ON TEMPERATURE FALL.

L2

L1

L1

T2

T1

T1

CT62A

CT62B

3

ELECTRIC
HEATER

CAUTION:

SPECIAL SERVICE CO/ALR SOLDERLESS CONNECTORS MUST 
BE USED WHEN CONNECTING WITH ALUMINUM CONDUCTORS;
OTHERWISE, A FIRE HAZARD CAN RESULT.

TO 
ELECTRIC
HEATER

M8420

5

 CHECK OUT THERMOSTAT

Turn on the power to the heating system.

Turn setting knob all the way clockwise

; listen

for clicking sound as switch makes contact. Electric

heater should begin operation.

Turn knob all the way counterclockwise

; listen

for clicking sound as switch breaks contact. Electric

heater should shut off.

6

 SETTING THERMOSTAT

Begin with setting knob at 70

°

F (20

°

C) on the scale.

If this setting is not satisfactory after at least two
hours of operation, turn setting knob upscale to

raise the temperature, or downscale to lower the tempera-
ture. Move knob only a degree each time.

Содержание CT62A

Страница 1: ...t base to outlet box and lift away Disconnect wires from old thermostat As you disconnect each wire tape the end and label it with the letter of the terminal designation to make reconnection to new thermostat easier Check the old insulation for cracks nicks or fraying and apply high quality plastic tape where necessary for adequate insulation Retain the old thermostat for reference purposes and un...

Страница 2: ...4 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED BREAKS ON POSITIVE OFF EXPOSED UNUSED LEADWIRES TO BE PROPERLY INSULATED THERMALLY ACTIVATED BREAKS ON TEMPERATURE RISE MAKES ON TEMPERATURE FALL L2 L1 L1 T2 T1 T1 CT62A CT62B 3 ELECTRIC HEATER CAUTION SPECIAL SERVICE CO ALR SOLDERLESS CONNECTORS MUST BE USED WHEN CONNECTING WITH ALUMINUM CONDUCTORS OTHERWISE A FIRE HAZARD...

Страница 3: ...e thermostat setting differs from the thermom eter record the temperature difference and recalibrate as instructed in the Recalibration Procedure section Recalibration Procedure Note the temperature difference between the temperature setting and the thermometer Remove the thermostat cover Rotate setting knob clockwise until you hear switch click Hold the setting knob firmly and rotate the set poin...

Страница 4: ... was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IM PLIED ORANY...

Отзывы: