Honeywell CT41A Скачать руководство пользователя страница 7

CT41A HEATING/COOLING THERMOSTAT

69-0788-2

Limited One-Year Warranty

Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of 
one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall 
repair or replace it (at Honeywell’s option) within a reasonable period of time.

If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or
(ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage prepaid, 

to the following address:

Honeywell Return Goods

Canada: Honeywell Limited/Honeywell Limitée

Dock 4, MN10-3860

Product Services ON15

1885 Douglas Dr N

35 Dynamic Dr

Golden Valley, MN 55422

Scarborough, Ontario M1V 4Z9

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was 
caused by damage which occurred while the product was in the possession of a consumer.

Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY 
LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, 
FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the 
exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED 
WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO 
THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation 
may not apply to you.

This warranty gives you specific legal rights, and you may have other rights which vary from state to state.

If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr N, MN10-1461, Golden Valley, MN 
55422. In Canada, write Retail Products ON15, Honeywell Limited/Honeywell Limitée, 35 Dynamic Dr, Scarborough, Ontario M1V 4Z9.

Содержание CT41A

Страница 1: ...te management authority for instructions regarding recycling and the proper disposal of an old control 1 PREPARE FOR INSTALLATION If you are unsure about wiring procedures please call a qualified service technician for assistance To correctly install your new thermostat follow these step by step instructions It is recommended that as you read understand and complete each step you place a check mar...

Страница 2: ... move on to the next step Fig 2 Locating heat anticipator adjustment mechanism Loosen screws holding thermostat to subbase wallplate or wall and lift away Disconnect wires from old thermostat or subbase As you disconnect each wire tape the end and label it with the letter of the terminal designation If there are only two wires they do not require labeling Wrap wires around a pencil to keep them fr...

Страница 3: ...e Fig 6 The primary control is usually a gas valve zone valve or a relay or burner control box with the thermostat wires connected to it For electric heat add the fan relay current usually 0 2A to 0 4A Fig 6 Locate your system current draw anticipator setting Set the heat anticipator indicator at the rating printed on the primary control See Fig 7 CAUTION Heat Anticipator Hazard Setting heat antic...

Страница 4: ... power to the heating air conditioning system Observe system operation for at least one cycle on both heating and air conditioning To observe Place the System switch at the Heat position and the Fan switch at the Auto position Move the temperature setting lever 10 F 6 C below room temperature The heating equipment should turn on A short warmup period may be required before system fan turns on NOTE...

Страница 5: ... stabilize Major swings in temperature greater than 2 F 1 C when outside temperature is stable Burner On period is too long Remove the thermostat cover and move the heat anticipator lever clockwise right one scale mark Replace the cover and wait several hours for the system to stabilize Thermostat setting and thermometer reading disagree Thermostat is not level Recheck the thermostat position on t...

Страница 6: ...ate thermometer After allowing five or ten minutes for stabilization compare the readings If the readings are the same replace the cover and put the system into operation If the readings are different insert a hex head wrench into the thermostat shaft and turn it until the thermometers have the same reading See Fig 8 Replace cover and put the system into operation Fig 8 Adjusting thermometer calib...

Страница 7: ...on was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR A...

Страница 8: ...OSTAT Printed in U S A on recycled paper containing at least 10 post consumer paper fibers Automation and Control Solutions Honeywell International Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 ...