CT41A HEATING/COOLING THERMOSTAT

69-0788-2

 4

4 CHECK OUT THERMOSTAT

The System switch controls as follows:

Heat

: heating system only operates.

Off

: heating and air conditioning systems are discon-

nected.

Cool

: air conditioning system only operates.

The Fan switch controls as follows:

Auto

: fan operates when heating or air conditioning 

system operates.

On

: fan operates continuously.

NOTE: In the following instructions, disregard heating 

or air conditioning directions if not applicable to 
your system.

CAUTION

Compressor Damage Hazard. 
Operating at too low of an outdoor 
temperature can cause compressor damage.

Do not operate cooling if outdoor temperature is 
below 50°F (10°C). 
Allow compressor to remain off for five minutes 
before restarting.
Refer to manufacturer’s recommendations.

Turn on power to the heating/air conditioning system.

Observe system operation for at least one cycle on 
both heating and air conditioning. To observe:

Place the System switch at  the Heat position and the 
Fan switch at the Auto position. Move the temperature 
setting lever 10°F (6°C) below room temperature. The 
heating equipment should turn on. A short warmup 
period may be required before system fan turns on.

NOTE: Some systems have a time delay that can pre-

vent operation up to five minutes.

Turn the Fan switch to On. The system fan should turn 
on and operate continuously. The system blower 
should continue to operate at any System switch or 
thermostat setting.

5 THERMOSTAT

Place the System and Fan switches at the desired 
settings for operation.

6 TROUBLESHOOTING (TABLE 2)

Your Honeywell thermostat requires little or no attention. 
Most problems can be resolved according to Table 2.

NOTE: If your system is heating-only or air 

conditioning-only, disregard sections not 
applicable to your system.

Содержание CT41A

Страница 1: ...te management authority for instructions regarding recycling and the proper disposal of an old control 1 PREPARE FOR INSTALLATION If you are unsure about wiring procedures please call a qualified service technician for assistance To correctly install your new thermostat follow these step by step instructions It is recommended that as you read understand and complete each step you place a check mar...

Страница 2: ... move on to the next step Fig 2 Locating heat anticipator adjustment mechanism Loosen screws holding thermostat to subbase wallplate or wall and lift away Disconnect wires from old thermostat or subbase As you disconnect each wire tape the end and label it with the letter of the terminal designation If there are only two wires they do not require labeling Wrap wires around a pencil to keep them fr...

Страница 3: ...e Fig 6 The primary control is usually a gas valve zone valve or a relay or burner control box with the thermostat wires connected to it For electric heat add the fan relay current usually 0 2A to 0 4A Fig 6 Locate your system current draw anticipator setting Set the heat anticipator indicator at the rating printed on the primary control See Fig 7 CAUTION Heat Anticipator Hazard Setting heat antic...

Страница 4: ... power to the heating air conditioning system Observe system operation for at least one cycle on both heating and air conditioning To observe Place the System switch at the Heat position and the Fan switch at the Auto position Move the temperature setting lever 10 F 6 C below room temperature The heating equipment should turn on A short warmup period may be required before system fan turns on NOTE...

Страница 5: ... stabilize Major swings in temperature greater than 2 F 1 C when outside temperature is stable Burner On period is too long Remove the thermostat cover and move the heat anticipator lever clockwise right one scale mark Replace the cover and wait several hours for the system to stabilize Thermostat setting and thermometer reading disagree Thermostat is not level Recheck the thermostat position on t...

Страница 6: ...ate thermometer After allowing five or ten minutes for stabilization compare the readings If the readings are the same replace the cover and put the system into operation If the readings are different insert a hex head wrench into the thermostat shaft and turn it until the thermometers have the same reading See Fig 8 Replace cover and put the system into operation Fig 8 Adjusting thermometer calib...

Страница 7: ...on was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR A...

Страница 8: ...OSTAT Printed in U S A on recycled paper containing at least 10 post consumer paper fibers Automation and Control Solutions Honeywell International Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 ...

Отзывы: