CT41A HEATING/COOLING THERMOSTAT

69-0788-2

Push excess wire back into wall and plug hole with 
nonflammable insulation to prevent drafts from 
affecting thermostat operation.

Remove thermostat cover by pulling outward on right 
edge of cover until it snaps free of the thermostat 
base.

Fasten thermostat to wall or vertical outlet box with a 
screw through the top mounting hole. See Fig. 2 for 
hole location.

Place a bubble level or plumb line against the 
thermostat to find the level position. See Fig. 5. Start a 
screw in the center of the bottom mounting hole. 
(Move the temperature setting lever, if necessary, to 
uncover the mounting hole.)

Fig. 5. Level thermostat.

Recheck for level positioning and firmly tighten both 
mounting screws.

Be sure you have the current draw anticipator setting 
for your system. This is the number you wrote in the 
box in step 2 Remove Old Thermostat section. If you 
could not find the current draw for step 2, look on your 
primary control at the furnace. See Fig. 6. (The 
primary control is usually a gas valve, zone valve, or a 
relay or burner control box with the thermostat wires 
connected to it. For electric heat, add the fan relay 
current, usually 0.2A to 0.4A.)

Fig. 6. Locate your system current draw anticipator 

setting.

Set the heat anticipator indicator at the rating printed 
on the primary control. See Fig. 7.

CAUTION

Heat Anticipator Hazard.
Setting heat anticipator too low can cause 
anticipator burnout.

Set heat anticipator at recommended rating to 
avoid shorting out your valve or control and 
prevent burnout of your heat anticipator.

Fig. 7. Set heat anticipator indicator to match your 

primary control rating.

Press thermostat cover firmly onto the mounting clips. 
See Fig. 2.

M3774

.18

.2

.25

3

.5

.7

.9

BUBBLE LEVEL

PLUMB
LINE

PLUMB
BOB OR
WEIGHT

V8043E 1004 4
24V 50/60CY

.32 AMP @ 60CY

8406

 

24 Vac 50/60 Hz

0.4 AMP

30 VAC

0.2 AMP

T

F

T

F

OIL BURNER CONTROL

SHOWS
CURRENT 
DRAW

SHOWS 
VOLTAGE
RATING

M6116B

FROM MAIN
FUEL SUPPLY

SHOWS
VOLTAGE
RATING

TO
BURNER

SHOWS
ANTICIPATOR
SETTING

TYPICAL GAS VALVE

ZONE VALVE

SHOWS
VOLTAGE
RATING

SHOWS
ANTICIPATOR
SETTING

.18

.2

.25

3

.5

.7

.9

SCALEPLATE

M3784

ADJUSTABLE 
HEAT
ANTICIPATOR
SETTING LEVER

Содержание CT41A

Страница 1: ...te management authority for instructions regarding recycling and the proper disposal of an old control 1 PREPARE FOR INSTALLATION If you are unsure about wiring procedures please call a qualified service technician for assistance To correctly install your new thermostat follow these step by step instructions It is recommended that as you read understand and complete each step you place a check mar...

Страница 2: ... move on to the next step Fig 2 Locating heat anticipator adjustment mechanism Loosen screws holding thermostat to subbase wallplate or wall and lift away Disconnect wires from old thermostat or subbase As you disconnect each wire tape the end and label it with the letter of the terminal designation If there are only two wires they do not require labeling Wrap wires around a pencil to keep them fr...

Страница 3: ...e Fig 6 The primary control is usually a gas valve zone valve or a relay or burner control box with the thermostat wires connected to it For electric heat add the fan relay current usually 0 2A to 0 4A Fig 6 Locate your system current draw anticipator setting Set the heat anticipator indicator at the rating printed on the primary control See Fig 7 CAUTION Heat Anticipator Hazard Setting heat antic...

Страница 4: ... power to the heating air conditioning system Observe system operation for at least one cycle on both heating and air conditioning To observe Place the System switch at the Heat position and the Fan switch at the Auto position Move the temperature setting lever 10 F 6 C below room temperature The heating equipment should turn on A short warmup period may be required before system fan turns on NOTE...

Страница 5: ... stabilize Major swings in temperature greater than 2 F 1 C when outside temperature is stable Burner On period is too long Remove the thermostat cover and move the heat anticipator lever clockwise right one scale mark Replace the cover and wait several hours for the system to stabilize Thermostat setting and thermometer reading disagree Thermostat is not level Recheck the thermostat position on t...

Страница 6: ...ate thermometer After allowing five or ten minutes for stabilization compare the readings If the readings are the same replace the cover and put the system into operation If the readings are different insert a hex head wrench into the thermostat shaft and turn it until the thermometers have the same reading See Fig 8 Replace cover and put the system into operation Fig 8 Adjusting thermometer calib...

Страница 7: ...on was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR A...

Страница 8: ...OSTAT Printed in U S A on recycled paper containing at least 10 post consumer paper fibers Automation and Control Solutions Honeywell International Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 ...

Отзывы: