69-1567

8

T8602C CHRONOTHERM

® 

IV DELUXE PROGRAMMABLE THERMOSTATS

Refer to Table 5 for the directions and results of the
specific tests.

Table 5. Installer System Test Options.

NOTE: Press any key and the displayed numbers will change. Press Time

  ▼

 to go to the previous test and Time 

to go to the next test. The Run Program key will not exit this test. Press Time 

 or Time 

 and then the

Run Program key to exit.

THERMOSTAT INFORMATION

1. Press the Time 

 

key to access the thermostat

information.

2. Press the increase s key to display the production

date code. The first two large digits are the month
and the third digit is the last digit of the year
(Example: 027 = February 1997).

3. Press the increase 

 key again to display the

software identification code.  (Example: 02 =
software ID code 2)

M14613

NOTE: Press Time 

 

to advance to the next test and

Time 

 to go back to the previous test. Press

Run Program to exit the system test.

4. Press the increase 

 key again to display the

software revision number (Example: 001 =
Revision number 1).

5. Press the increase 

 key again to display the

EEPROM identification code. (Example: 314 =
EEPROM ID 314)

6. Press the Run Program key to exit the system

test. The system test times out after four minutes
without any key presses.

M14614

M14615

M14616

M14617

Key to

Press

Test

Number

Description

Heating Equipment System Test

Time 

10

Enter heating equipment system test.  

11

Heat comes on. When Installer Setup number 2 is 1, the system fan is also energized.

10

Heat and system fan turn off.

Cooling Equipment System Test

Time 

30

Change from heating to cooling equipment system test.  

31

Cool and system fan come on.

30

Cool and system fan turn off.

Fan Equipment System Test  

Time 

40

Change from cooling to fan equipment system test.

41

Fan comes on.

40

Fan turns off.

Key Operation System Test  

Time 

60   2

Change from fan to key operation system test.

Содержание Chronotherm IV T8602C

Страница 1: ...tructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After completing installation use these instruc tions to check out the product operation Location Install the thermostat about 1 5m 5 ft above the floor in an area with good air circulation at average temperature See Fig 1 Do not install the thermost...

Страница 2: ...ghten mounting screws WIRING All wiring must comply with local electrical codes and ordinances Refer to Fig 3 for typical hookup A letter code is located near each terminal for identification CAUTION Disconnect power before wiring to prevent electrical shock or equipment damage 1 Loosen the terminal screws on the wallplate and connect the system wires See Fig 4 IMPORTANT Use 18 gauge color coded t...

Страница 3: ...ACTOR HEATING TRANSFORMER COOLING TRANSFORMER 2 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED JUMPER RC TERMINAL TO R TERMINAL WHEN INSTALLED ON A ONE TRANSFORMER SYSTEM AVAILABLE ON SELECT MODELS OT WIRES MUST HAVE A SEPARATE CABLE FROM THE THERMOSTAT CABLE 2 1 1 3 OT OT OUTDOOR TEMPERATURE SENSOR 3 Fig 4 Proper wiring technique M4826 FOR WRAPAROUND INSERTION STRIP 7...

Страница 4: ... FORWARD THROUGH INSTALLER SETUP OPTIONS DECREASE TEMPERATURE SETTING OR SCROLL BACKWARD THROUGH INSTALLER SETUP OPTIONS DISPLAY INFORMATION SUCH AS PRESENT SETTINGS AND OUTDOOR TEMPERATURE RETURN TO NORMAL OPERATIONS ENTER INDEFINITE OR TIMED HOLD MODE SET CURRENT DAY AND TIME SET CURRENT OR PROGRAM DAY CHANGE BETWEEN DAYLIGHT SAVINGS AND STANDARD TIME INCREASE TIME SETTING OR SCROLL FORWARD THRO...

Страница 5: ...used to customize the thermostat to specific systems Some of the options include temperature display system changeover and outdoor temperature display Installer Setup numbers are listed in Table 3 The table includes all the configuration options and the factory settings for the T8602 A combination of key presses are required to use the Installer Setup feature To enter the installer setup press and...

Страница 6: ... 23 Outdoor temperature display select models 24 0 No outdoor temperature is displayed 1 Outdoor temperature is displayed Needs a C7089B1000 Outdoor Sensor to operate Not used 25 thru 32 Minimum off time for the compressor 33 5 5 minute minimum off time for the compressor 0 thru 4 Minimum number of minutes 0 thru 5 the compressor will be off between calls for the compressor Temperature range stops...

Страница 7: ... Time until DST is displayed M14622 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Daylight Time Copy Set Day Time AM DST Tue 4 Press Run Program M14623 Time Set Program System Fan Run Program Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy Wake Room Sys...

Страница 8: ...est and Time to go back to the previous test Press Run Program to exit the system test 4 Press the increase key again to display the software revision number Example 001 Revision number 1 5 Press the increase key again to display the EEPROM identification code Example 314 EEPROM ID 314 6 Press the Run Program key to exit the system test The system test times out after four minutes without any key ...

Страница 9: ...wer temperature limits were reached Check the temperature setpoints Heating limits are 4 5 to 32 C Cooling limits are 7 to 37 C heating higher or the cooling lower The setpoint temperature range stops were configured Check Installer Setup numbers 34 and 35 and reconfigure the setpoint stops Heating will not come on No power to the thermostat Check for 24 Vac between R and W terminals If missing 24...

Страница 10: ...t is opening up or becoming high impedance Add resistor in parallel with load or install interface relay System on indicator flame heat snowflake cool is Fan operation set for 0 con ventional heat when it should be set for 1 electric heat Enter Installer Setup number 2 and reconfigure the fan operation displayed but no warm or cool air is coming from the registers Conventional heating equipment tu...

Страница 11: ...69 1567 11 T8602C CHRONOTHERM IV DELUXE PROGRAMMABLE THERMOSTATS ...

Страница 12: ...Taiwan R O C www honeywell com yourhome Home and Building Control Honeywell Limited Honeywell Limitée 35 Dynamic Drive Scarborough Ontario M1V 4Z9 Home and Building Control Honeywell 1985 Douglas Drive North Golden Valley MN 55422 ...

Отзывы: