Honeywell Chronotherm IV T8602C Скачать руководство пользователя страница 5

69-1567

5

T8602C CHRONOTHERM

® 

IV DELUXE PROGRAMMABLE THERMOSTATS

Temperature Settings

Refer to Table 2 for the default program. If the daytime
energy savings period is not used, press the period key
(Leave or Return) until the time is blank. The fan setting
feature is available on select thermostat models. See
Owners Guide, form number 69-0940, for complete
instructions on changing the program.

Table 2. Default Program Settings.

Fig. 9. Display of Installer Setup number and setting.

CAUTION

Electric heat systems must be configured to 1 in
Installer Setup number 2 to prevent equipment
damage caused by the system running without
the fan.

IMPORTANT

Only configurable numbers are shown on the
device. Example: If thermostat does not have a
system key, Installer Setup Number 12 will not
be displayed. Review Table 3 factory-settings
and mark any desired changes in the Actual
Setting column. When Installer Setup is
complete, review the settings to confirm that
they match the system.

INSTALLER SETUP

NOTE: For most applications, the thermostat factory-

settings will not need to be changed. Review
the factory settings in Table 2 and if no
changes are necessary, go to the Installer Self-
Test section.

The Installer Setup is used to customize the thermostat
to specific systems. Some of the options include
temperature display, system changeover and outdoor
temperature display. Installer Setup numbers are listed
in Table 3. The table includes all the configuration
options and the factory-settings for the T8602.

A combination of key presses are required to use the
Installer Setup feature.

To enter the installer setup, press and hold the
information  

 i   

key with the increase 

 and

decrease 

 keys until the first number is displayed.

All display segments appear for approximately
three seconds before the number is displayed. See
Fig. 8 and 9.

To advance to the next Installer Setup, press the
Time 

 

key.

To change a setting, use the increase 

 or

decrease 

 key.

To scroll the Installer Setup numbers backwards,
press the Time 

 

key.

To exit the Installer Setup, press Run Program.

Fig. 8. Display of all the segments of the LCD.

M14618

INSTALLER SETUP
NUMBER DISPLAY
(COLUMN 2 OF TABLE 3)

FACTORY SETTING OR OTHER 
CHOICE DISPLAY (COLUMN 3
OR 5 OF TABLE 3)

Period

Time

Heat

Setpoint

Cool

Setpoint

Fan

Setting

Wake

6:45 AM

20°C

25°C

Auto

Leave

8:45 AM

4.5°C

37°C

Auto

Return

5:00 PM

20°C

25°C

Auto

Sleep

10:00 PM

4.5°C

37°C

Auto

M14559

Aux Ht

Set Day/Time

Set Program

Mon
Wake Leave Return

Sleep

Outdoor

Room

Filter

Wait

System

Fan

Em Heat

On

Auto

Off

Cool

Auto

AM

PM

Hold for

Heat

Cool

Repl Batt

Recovery

DST

Tue Wed Thu Fri Sat Sun

Days

Temporary Setting

Em Ht

Содержание Chronotherm IV T8602C

Страница 1: ...tructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After completing installation use these instruc tions to check out the product operation Location Install the thermostat about 1 5m 5 ft above the floor in an area with good air circulation at average temperature See Fig 1 Do not install the thermost...

Страница 2: ...ghten mounting screws WIRING All wiring must comply with local electrical codes and ordinances Refer to Fig 3 for typical hookup A letter code is located near each terminal for identification CAUTION Disconnect power before wiring to prevent electrical shock or equipment damage 1 Loosen the terminal screws on the wallplate and connect the system wires See Fig 4 IMPORTANT Use 18 gauge color coded t...

Страница 3: ...ACTOR HEATING TRANSFORMER COOLING TRANSFORMER 2 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED JUMPER RC TERMINAL TO R TERMINAL WHEN INSTALLED ON A ONE TRANSFORMER SYSTEM AVAILABLE ON SELECT MODELS OT WIRES MUST HAVE A SEPARATE CABLE FROM THE THERMOSTAT CABLE 2 1 1 3 OT OT OUTDOOR TEMPERATURE SENSOR 3 Fig 4 Proper wiring technique M4826 FOR WRAPAROUND INSERTION STRIP 7...

Страница 4: ... FORWARD THROUGH INSTALLER SETUP OPTIONS DECREASE TEMPERATURE SETTING OR SCROLL BACKWARD THROUGH INSTALLER SETUP OPTIONS DISPLAY INFORMATION SUCH AS PRESENT SETTINGS AND OUTDOOR TEMPERATURE RETURN TO NORMAL OPERATIONS ENTER INDEFINITE OR TIMED HOLD MODE SET CURRENT DAY AND TIME SET CURRENT OR PROGRAM DAY CHANGE BETWEEN DAYLIGHT SAVINGS AND STANDARD TIME INCREASE TIME SETTING OR SCROLL FORWARD THRO...

Страница 5: ...used to customize the thermostat to specific systems Some of the options include temperature display system changeover and outdoor temperature display Installer Setup numbers are listed in Table 3 The table includes all the configuration options and the factory settings for the T8602 A combination of key presses are required to use the Installer Setup feature To enter the installer setup press and...

Страница 6: ... 23 Outdoor temperature display select models 24 0 No outdoor temperature is displayed 1 Outdoor temperature is displayed Needs a C7089B1000 Outdoor Sensor to operate Not used 25 thru 32 Minimum off time for the compressor 33 5 5 minute minimum off time for the compressor 0 thru 4 Minimum number of minutes 0 thru 5 the compressor will be off between calls for the compressor Temperature range stops...

Страница 7: ... Time until DST is displayed M14622 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Daylight Time Copy Set Day Time AM DST Tue 4 Press Run Program M14623 Time Set Program System Fan Run Program Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy Wake Room Sys...

Страница 8: ...est and Time to go back to the previous test Press Run Program to exit the system test 4 Press the increase key again to display the software revision number Example 001 Revision number 1 5 Press the increase key again to display the EEPROM identification code Example 314 EEPROM ID 314 6 Press the Run Program key to exit the system test The system test times out after four minutes without any key ...

Страница 9: ...wer temperature limits were reached Check the temperature setpoints Heating limits are 4 5 to 32 C Cooling limits are 7 to 37 C heating higher or the cooling lower The setpoint temperature range stops were configured Check Installer Setup numbers 34 and 35 and reconfigure the setpoint stops Heating will not come on No power to the thermostat Check for 24 Vac between R and W terminals If missing 24...

Страница 10: ...t is opening up or becoming high impedance Add resistor in parallel with load or install interface relay System on indicator flame heat snowflake cool is Fan operation set for 0 con ventional heat when it should be set for 1 electric heat Enter Installer Setup number 2 and reconfigure the fan operation displayed but no warm or cool air is coming from the registers Conventional heating equipment tu...

Страница 11: ...69 1567 11 T8602C CHRONOTHERM IV DELUXE PROGRAMMABLE THERMOSTATS ...

Страница 12: ...Taiwan R O C www honeywell com yourhome Home and Building Control Honeywell Limited Honeywell Limitée 35 Dynamic Drive Scarborough Ontario M1V 4Z9 Home and Building Control Honeywell 1985 Douglas Drive North Golden Valley MN 55422 ...

Отзывы: